qk008rh3 Littelfuse, Inc., qk008rh3 Datasheet - Page 8

no-image

qk008rh3

Manufacturer Part Number
qk008rh3
Description
Teccor Brand Thyristors Teccor Brand Thyristors 8 Amp Sensitive, Standard & Alternistor High Commutation Triacs
Manufacturer
Littelfuse, Inc.
Datasheet
Lxx08xx & Qxx08xx & Qxx08xHx Series
Soldering Parameters
Reflow Condition
Pre Heat
Average ramp up rate (Liquidus Temp)
(T
T
Reflow
Peak Temperature (T
Time within 5°C of actual peak
Temperature (t
Ramp-down Rate
Time 25°C to peak Temperature (T
Do not exceed
Physical Specifications
Terminal Finish
Body Material
Terminal Material
Design Considerations
Careful selection of the correct device for the application’s
operating parameters and environment will go a long way
toward extending the operating life of the Thyristor. Good
design practice should limit the maximum continuous
current through the main terminals to 75% of the device
rating. Other ways to ensure long life for a power discrete
semiconductor are proper heat sinking and selection of
voltage ratings for worst case conditions. Overheating,
overvoltage (including dv/dt), and surge currents are
the main killers of semiconductors. Correct mounting,
soldering, and forming of the leads also help protect
against component damage.
S(max)
L
8 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs
) to peak
to T
L
- Ramp-up Rate
- Temperature Min (T
- Temperature Max (T
- Time (min to max) (t
- Temperature (T
- Temperature (t
p
)
P
)
100% Matte Tin-plated
UL recognized epoxy meeting flammability
classification 94V-0
Copper Alloy
L
L
)
) (Liquidus)
s(min)
s(max)
s
)
P
)
)
)
Pb – Free assembly
150°C
200°C
60 – 180 secs
5°C/second max
5°C/second max
217°C
60 – 150 seconds
260
20 – 40 seconds
5°C/second max
8 minutes Max.
280°C
Teccor
+0/-5
°C
®
Revised: July 9, 2008
brand Thyristors
82
AC Blocking (V
Temperature Cycling
Temperature/
Humidity
High Temp Storage
Low-Temp Storage
Thermal Shock
Autoclave
Resistance to
Solder Heat
Solderability
Lead Bend
Environmental Specifications
T
T
S(max)
S(min)
25
T
T
Test
P
L
DRM
time to peak temperature
)
Please refer to http://www.littelfuse.com for current information.
Please refer to http://www.littelfuse.com for current information.
t
MIL-STD-750, M-1040, Cond A Applied
Peak AC voltage @ 125°C for 1008 hours
MIL-STD-750, M-1051,
100 cycles; -40°C to +150°C; 15-min
dwell-time
EIA / JEDEC, JESD22-A101
1008 hours; 320V - DC: 85°C; 85%
rel humidity
MIL-STD-750, M-1031,
1008 hours; 150°C
1008 hours; -40°C
MIL-STD-750, M-1056
10 cycles; 0°C to 100°C; 5-min dwell-
time at each temperature; 10 sec (max)
transfer time between temperature
EIA / JEDEC, JESD22-A102
168 hours (121°C at 2 ATMs) and
100% R/H
MIL-STD-750 Method 2031
ANSI/J-STD-002, category 3, Test A
MIL-STD-750, M-2036 Cond E
S
Preheat
Preheat
Specifications and Conditions
Ramp-up
Ramp-up
Specifications are subject to change without notice.
Specifications are subject to change without notice.
t
t
P
L
Ramp-down
Ramp-do
Time
©2008 Littelfuse, Inc.