I Features
The DigitroniK SDC35/36 is a digital indicating control-
ler featuring multi-range inputs and PID control system
using new algorithms "RationaLOOP" and "Just-FiTTER".
Up to two control output points (this number of points
may vary depending on the model) can be used, which
are selectable from the relay contact, voltage pulse, con-
tinuous voltage, and current.
The smart loader package ensures easy setting operation
and monitoring.
This controller is compliant to the IEC directives and the
CE marking.
• Space saving design with a depth of 65mm.
• High accuracy of ±0.1%FS and sampling cycle of 0.1s
• Multi-range inputs are available for selection, where the
• The control method can be selected from any of the ON/
I Basic Function Block of SDC35/36
Communication input/output
Process variable (PV) input
The mask of the front panel is also only 5mm thick.
(seconds).
input type can be freely changed among thermocouple,
RTD, current, and voltage.
OFF control and PID control using "RationaLOOP" +
"Just-FiTTER".
RSP (remote SP) input
External switch input
(4 points)
Current transformer (CT) input
• Thermocouple, RTD,
• Filter
• Ratio/bias
• DC current, DC voltage inputs
• RSP upper/lower limit scaling
• Filter
• Ratio/bias
• Set point (SP) value, 8 groups
• RUN/READY selection
• AUTO/MANUAL selection
• LSP/RSP selection
• Latch cancellation, etc.
• RS-485 (3-wire)
DC current, DC voltage inputs
setting
of selection
Motor feedback (MFB) input
Single Loop Controller
(2 points)
SDC35/36
• Either of ON/OFF control
• Direct/Reverse action
• Heat/Cool operation
or PID control is selected.
100 to 240Vac 50/60Hz
Control operation
Power supply
* 24Vac/24Vdc
1
• The heat/cool control can be achieved using two control
• The RS-485 communication function is provided as an
• The control output types available for selection are re-
• Event 3 points or 2 points (independent contact), CT in-
• The smart loader package (SLP-C35) can be used.
output points and event outputs.
optional function.
lay, voltage pulse, current, and continuous voltage out-
puts which can be combined.
put 2 points, DI 4 points, and RSP inputs, RS-485 can be
selected in combination.
• Relay contact
• Voltage pulse output
• Current output
Above outputs are combined.
• Continuous voltage output
• PV upper limit, lower limit,
• Deviation upper limit, lower limit,
• SP upper limit, lower limit,
• MV upper limit, lower limit,
• Heater burnout, etc.
• Personal computer loader
• 0 to 20mA/4 to 20mA
• 0 to 5V/1 to 5V/0 to 10V
upper/lower limit
upper/lower limit
upper/lower limit
upper/lower limit
Units marked with an asterisk (*)
will be available in the near future.
No. CP–SS–1820E
Auxiliary output
Loader communication
Event output
Control (MV) output
(3 points)
(2 points)

Related parts for rsa6351p

rsa6351p Summary of contents

Page 1

Single Loop Controller I Features The DigitroniK SDC35/ digital indicating control- ler featuring multi-range inputs and PID control system using new algorithms "RationaLOOP" and "Just-FiTTER" two control output points (this number of points may vary depending ...

Page 2

I Specifications PV input Input type Multi-range of inputs - thermocouple, RTD, DC current and DC voltage Input sampling time 100ms Input impedance DC voltage input: Min. 1MΩ, DC current input: Max. 100Ω Input bias -1999 to +9999 or -199.9 ...

Page 3

Auxiliary output Output type Load resistance Output accuracy Output resolution External Number of inputs Max. 4 points contact input Function kinds of setting value (SP) selections, PID group selection, RUN/READY selection, AUTO/MANUAL (DI) selection, LSP/RSP selection, Auto ...

Page 4

Event Event type G shows that the ON/ The event is turned ON when any change in PV corresponding to increase/decrease in MV (Manipulated OFF is changed at variable) is not observed. this value. This event is used to detect ...

Page 5

Event Event type G shows that the ON/ The event is turned ON when any change in PV corresponding to increase/decrease in MV (Manipulated OFF is changed at variable) is not observed. this value. . This event is used to ...

Page 6

Event Event type G shows that the ON/ The direct and reverse action settings are disabled for the timer event. OFF is changed at When using the timer event necessary to set the operation type of the DI ...

Page 7

General Memory backup Semiconductor non-volatile memory specifications Power supply voltage AC power supply model 264Vac, 50/60Hz±2Hz Power consumption AC power supply model: Max. 12VA Insulation resistance Between power supply terminal and secondary terminal, 500Vdc, 10MΩ or more Dielectric ...

Page 8

Table 1 Input Types and Ranges Input type C01 No. Sensor type Thermo -200 to +1200°C couple 1200° 800° 0.0 to 600.0° 0.0 to 400.0°C 6 ...

Page 9

I Model Selection Guide VI VII VIII I II III III IV V Basic Mount- Control PV Power Option Option Additional model ing output input supply No. C35 C36 ...

Page 10

I Dimensions G C35 5 Mounting bracket 48 (Accessory) SDC35 pv sp out man rsp ev1 ev2 ev3 ot1 ot2 mode display enter para G C36 96 SDC36 man pv rsp ev1 ev2 ev3 sp ot1 out ot2 mode display ...

Page 11

I Part Names and Functions (1) SDC35 man pv pv rsp ev1 sp (2) ev2 out ev3 sp ot1 out man rsp ev1 ev2 ev3 ot1 ot2 (3) ot2 (4) mode display mode (5) (6) (5) enter para (9) para ...

Page 12

... RESTRICTIONS ON USE • Control devices for nuclear reactors No part of this publication may be reproduced or duplicated without the prior written permission of Yamatake Corporation. 12 Line filter Yamatake’s model No. E81446364-001 (Equivalent to ZAC2205-00U ...