sl300ps24-c XP Power Limited, sl300ps24-c Datasheet

no-image

sl300ps24-c

Manufacturer Part Number
sl300ps24-c
Description
Power Module 300-600 Watts Sl
Manufacturer
XP Power Limited
Datasheet
300-600 Watts
SL & SLM Series
Specification
Input
Output
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current • SL models: <2.5 mA at 264 VAC/50 Hz
Input Protection
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Line Regulation
Load Regulation
Transient Response
Ripple & Noise
Overvoltage Protection • 120% approx Vnom
Overtemperature
Protection
Overload Protection
Short Circuit Protection • Constant current
Temperature
Coefficient
Remote On/Off
Current Share
• 90-264 VAC (125-360 VDC)
• 44-66 Hz
• 300 W models: 4.4 A at 90 VAC
• 100 A at 230 VAC
• 0.9 typical
• 10 A HRC fuse
• See table
• See table
• ±1% max
• No minimum load required
• 600 ms max
• 150 ms max
• 18 ms min
• <0.5% V min to V max
• <2.0% for a 0-100% load change
• 2% max deviation, recovery to within
• 1% pk-pk max, 20 MHz BW
• Fitted to 600 W models only,
• 110% typical, constant current
• 0.02%/°C
• Output inhibited by shorting
• Allows up to 5 units to share within 5%
600 W models: 8.9 A at 90 VAC
SLM models: <100 µA at 264 VAC/50 Hz
0.25% in 1 ms for a 10% load change
recycle mains to reset
ROF pin to 0 V
1.8 A at 230 VAC
3.5 A at 230 VAC
General
Environmental
EMC & Safety
Efficiency
Isolation
Switching Frequency
Signals
MTBF
Operating Temperature • -20 °C to +70 °C, derate from +40 °C
Operating Humidity
Storage Temperature
Operating Altitude
Shock
Vibration
Airflow Direction
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
Industrial (SL) & Medical (SLM) Versions
Output Voltages from 12 V to 96 V
Power Factor Corrected
Remote On/Off
Current Share
Power Fail Signal
Overtemperature Protection
• 85% typical
• 6000 VDC Input to Output
• 30-35 kHz PFC, 45-55 kHz PWM
• AC OK - TTL compatible signal is high
• 105 kHrs typical per MIL-HDBK-217E
• Up to 90% RH, non-condensing
• -25 °C to +85 °C
• 3000 m
• Non operating. 100 mm drop on
• Operating 5-50 Hz 0.05 mm pk-pk,
• Where fitted, fans blow air into the unit
• EN55022, level B conducted
• EN61000-3-2, class A
• EN61000-3-3
• EN61000-4-2, level 3 Perf Criteria A
• EN61000-4-3, level 3 Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, level 3 Perf Criteria A
• EN61000-4-11, 30% 10 ms,
• SL: UL60950, CSA22.2 No.60950
(Y caps disconnected)
2200 VDC Input to Ground
2200 VDC Output to Chassis
with reference to 0 V when AC is OK
at +20 °C. Consult office for each model
to 50% power at +70 °C
to chassis face
50-100 Hz 0.025 mm pk-pk
EN55022, level A radiated
60% 100 ms, 100% 5000 ms
Perf Criteria A, B, B
SLM: UL2601-1, CSA C22.2 No.60601-1
xppower.com

Related parts for sl300ps24-c

sl300ps24-c Summary of contents

Page 1

Watts SL & SLM Series Specification Input Input Voltage • 90-264 VAC (125-360 VDC) Input Frequency • 44-66 Hz Input Current • 300 W models: 4 VAC 600 W models: 8 VAC Inrush ...

Page 2

Model Numbering Power Style (Watts) ( Standard 300 SLM = Medically 600 Approved EXAMPLE Standard 300 = Power Notes 1. 300 W models are convection-cooled. 600 W models are fan-cooled. 2. Not available ...

Related keywords