mc68hc711k4 Freescale Semiconductor, Inc, mc68hc711k4 Datasheet - Page 208

no-image

mc68hc711k4

Manufacturer Part Number
mc68hc711k4
Description
Hcmos Microcontroller Unit
Manufacturer
Freescale Semiconductor, Inc
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
mc68hc711k4CFN3
Manufacturer:
MOLEX
Quantity:
12 000
Part Number:
mc68hc711k4CFN3
Manufacturer:
FREESCALE
Quantity:
3 181
Part Number:
mc68hc711k4CFN3
Manufacturer:
MOTOROLA/摩托罗拉
Quantity:
20 000
Part Number:
mc68hc711k4CFN4
Manufacturer:
FREESCALE
Quantity:
718
Part Number:
mc68hc711k4CFN4
Manufacturer:
FREESCALE
Quantity:
3 180
Part Number:
mc68hc711k4CFN4
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
mc68hc711k4CFNE4
Manufacturer:
ZARLINK
Quantity:
45
Part Number:
mc68hc711k4CFU4
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
mc68hc711k4VFN4
Manufacturer:
FREESCALE
Quantity:
800
Timing System
9.7.5 Pulse Accumulator Count Register
9.8 Real-Time Interrupt (RTI)
Technical Data
208
Address: $0027
In event counting mode, PACNT contains the count of external input
events at the PAI input. In gated accumulation mode, PACNT is
incremented by the pulse accumulator’s E
is at the selected level. Counting is synchronized to the internal PH2
clock so that incrementing and reading occur during opposite half cycles.
The counter is not affected by reset and can be read or written to at any
time.
The real-time interrupt (RTI) feature generates hardware interrupts at a
fixed periodic rate. The rate is determined by bits RTR[1:0] in the PACTL
register, which further divide a clock running at E
The resulting periods for various common crystal frequencies are shown
in
Every cycle of the RTI clock sets the RTIF bit in timer interrupt flag 2
(TFLG2) register. This flag can be polled to determine when RTI
timeouts occur, or an interrupt can be generated if the RTII bit in the
timer interrupt mask 2 (TMSK2) register is set. After reset, one entire
real-time interrupt period elapses before the RTIF flag is set for the first
time.
The clock source for the RTI function is a free-running clock that cannot
be stopped or interrupted except by reset. The time between successive
RTI timeouts is a constant that is independent of software latencies
Reset:
Read:
Write:
Table
Freescale Semiconductor, Inc.
Figure 9-26. Pulse Accumulator Count Register (PACNT)
For More Information On This Product,
Bit 7
Bit 7
9-7.
0
Go to: www.freescale.com
Bit 6
Timing System
6
0
Bit 5
5
0
Bit 4
4
0
Bit 3
3
0
64 clock when the PAI input
Bit 2
2
0
2
13
by 1, 2, 4 or 8.
M68HC11K Family
Bit 1
1
0
MOTOROLA
Bit 0
Bit 0
0