ltk001 Linear Technology Corporation, ltk001 Datasheet

no-image

ltk001

Manufacturer Part Number
ltk001
Description
Thermocouple Cold Junction Compensator And Matched Amplifier
Manufacturer
Linear Technology Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ltk001ACN8#PBF
Manufacturer:
AKM
Quantity:
1 001
Part Number:
ltk001CN8#PBF
Manufacturer:
Maxim
Quantity:
140
FEATURES
DESCRIPTIO
TYPICAL APPLICATIO
APPLICATIO S
The LTK001 is a thermocouple amplifier supplied with a
matched cold junction compensator. By separating the
amplifier and compensator functions, the problem of
compensator temperature rise is virtually eliminated. The
compensator is a selected version of the LT
junction compensator. The amplifier, which is also avail-
able separately as LTKA0x has been specially selected for
0.75°C Initial Accuracy (A Version)
Extremely Low Warmup Drift
Preset Outputs for Type E, J, K, R, S, T
Single 5V to ± 20V Operation
480µA Typical Supply Current
Available in 8-Pin DIP Package
Thermocouple Cold Junction Compensation
U
U
GND
LT1025
V
V +
U
IN
R –
V
K
0
V –
R4*
TYPE K
1%
R1
1k
*
®
Type K 10mV/°C Thermometer
1025 cold
+
0.1µF
FULL-SCALE TRIM
C1
100Ω
**SELECTED FOR 0°C–100°C RANGE
* R4 ≤
R2
LT1025 TEMPERATURES ≥ 0°C.
30µA
+
V –
LTKA0x
Thermocouple Cold Junction
thermocouple applications. It has low supply current to
minimize warmup drift, very low offset voltage (<35µV),
high gain, and extremely low input bias currents (<600pA)
to allow high impedance input filters to be used without
degrading offset voltage or drift.
Matching of the kits is accomplished by separating the
compensators and amplifiers according to the polarity of
their initial (room temperature) errors. This eliminates the
need to sum the errors of the two components to find the
worst-case error.
The LTK001 has direct thermocouple outputs of
60.9µV/°C (E), 51.7µV/°C (J), 40.6µV/°C (K, T), and
5.95µV/°C (R, S). It also has a 10mV/°C output which can
be scaled to match any arbitrary thermocouple.
For multiple thermocouple applications using one com-
pensator, amplifiers may be ordered separately (LTKA0x),
still matched to the compensator.
trademarks are the property of their respective owners. For typical performance curves and
applications circuits consult the LT1025 data sheet.
R3**
255k
, R4 IS NOT REQUIRED (OPEN) FOR
1%
V +
V –
, LTC and LT are registered trademarks of Linear Technology Corporation. All other
C2
0.1µF
V
10mV/°C
OUT
Matched Amplifier
Compensator and
LTK001 TA01
LTK001
1
001fa

Related parts for ltk001

ltk001 Summary of contents

Page 1

... APPLICATIO S ■ Thermocouple Cold Junction Compensation U DESCRIPTIO The LTK001 is a thermocouple amplifier supplied with a matched cold junction compensator. By separating the amplifier and compensator functions, the problem of compensator temperature rise is virtually eliminated. The compensator is a selected version of the LT junction compensator. The amplifier, which is also avail- ...

Page 2

... Consult factory for parts specified with wider operating temperature ranges (Note 1) Both Devices Operating Temperature Range LTK001AMJ8, LTK001MJ8 (OBSOLETE) ......................................................... – 55°C to 125°C LTK001ACN8, LTK001CN8 ...................... 0°C to 70°C Storage Temperature Range ................. – 65°C to 150°C Lead Temperature Range (Soldering, 10 sec.)...... 300° TOP VIEW V TRIM ...

Page 3

... Type J Type K, T Type R, S (Note 12) ≤ 70°C Type E Type J Type K, T Type R, S ≤ 70°C Type E Type J Type K, T Type R, S (Note 12) ≤ 125°C Type E J Type J Type K, T Type R, S (Note 12) LTK001 LTK001 TYP MAX MIN TYP MAX 0.75 2.5 0.75 2.5 0.86 2.5 5.0 5.0 0.05 0.09 0.06 0.09 0.07 0.10 0.28 0.32 2 ...

Page 4

... LT1025) CONDITIONS T = 25°C, LTK001A 25°C, LTK001 J ● Full Temperature Span LTK001A LTK001A LTK001 LTK001 ● Full Temperature Span 4V ≤ V ≤ 36V IN ● 0°C ≤ T ≤ 70°C J ● – 55°C ≤ T ≤ 125° ≤ ...

Page 5

... Load regulation is 30µA ≤ I Note 12: Larger errors with type R and S thermocouples are due mostly to 35µV offset of the amplifier. This error can be reduced to 5µV max with the ® LTC 1050 or LTC1052 operational amplifiers. LTK001 = 25°C. A AMPLIFIER (LTKA0x) MIN TYP ...

Page 6

... LTK001 PACKAGE DESCRIPTIO SEATING PLANE 45° Package 8-Lead TO-5 Metal Can (.200 Inch PCD) (Reference LTC DWG # 05-08-1320) .335 – .370 (8.509 – 9.398) DIA .305 – .335 (7.747 – 8.509) .040 .050 (1.016) MAX (1.270) MAX .010 – .045* (0.254 – 1.143) .016 – ...

Page 7

... HALF LEAD OPTION .025 (0.635) RAD TYP 1 0° – 15° .045 – .065 (1.143 – 1.651) .014 – .026 (0.360 – 0.660) OBSOLETE PACKAGE LTK001 .405 (10.287) MAX .220 – .310 (5.588 – 7.874 .200 (5 ...

Page 8

... LTK001 PACKAGE DESCRIPTIO .300 – .325 (7.620 – 8.255) .008 – .015 (0.203 – 0.381) +.035 .325 –.015 ( ) +0.889 8.255 –0.381 NOTE: 1. DIMENSIONS ARE MILLIMETERS *THESE DIMENSIONS DO NOT INCLUDE MOLD FLASH OR PROTRUSIONS. MOLD FLASH OR PROTRUSIONS SHALL NOT EXCEED .010 INCH (0.254mm) ...

Related keywords