at90ls4433 ATMEL Corporation, at90ls4433 Datasheet - Page 41

no-image

at90ls4433

Manufacturer Part Number
at90ls4433
Description
At90s4433 8-bit Avr Microcontroller With 4k Bytes Of In-system Programmable Flash
Manufacturer
ATMEL Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
at90ls4433-4AC
Manufacturer:
ATM
Quantity:
72
Part Number:
at90ls4433-4AI
Manufacturer:
HYNIX
Quantity:
14
Part Number:
at90ls4433-4AI
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
at90ls44334AC
Manufacturer:
ON
Quantity:
3 617
Timer/Counter1 Input Capture
Register – ICR1H and ICR1L
Timer/Counter1 in PWM Mode
1042H–AVR–04/03
The Input Capture Register is a 16-bit, read only register.
When the rising or falling edge (according to the input capture edge setting [ICES1]) of
the signal at the Input Capture Pin (ICP) is detected, the current value of the
Timer/Counter1 is transferred to the Input Capture Register (ICR1). At the same time,
the Input Capture Flag (ICF1) is set (one).
Since the Input Capture Register (ICR1) is a 16-bit register, a temporary register
(TEMP) is used when ICR1 is read to ensure that both bytes are read simultaneously.
When the CPU reads the Low Byte, ICR1L, the data is sent to the CPU and the data of
the High Byte, ICR1H, is placed in the TEMP Register. When the CPU reads the data in
the High Byte, ICR1H, the CPU receives the data in the TEMP Register. Consequently,
the Low Byte, ICR1L, must be accessed first for a full 16-bit register read operation.
The TEMP Register is also used when accessing TCNT1 and OCR1. If the main pro-
gram and interrupt routines perform access to registers using TEMP, interrupts must be
disabled during access from the main program.
When the PWM mode is selected, Timer/Counter1 and the Output Compare Register1
(OCR1) form a 8-, 9-, or 10-bit, free-running, glitch-free, phase correct PWM with output
on the PB1(OC1) pin. Timer/Counter1 acts as an up/down counter, counting up from
$0000 to TOP (see Table 13), where it turns and counts down again to zero before the
cycle is repeated. When the counter value matches the contents of the 8, 9, or 10 least
significant bits of OCR1, the PB1(OC1) pin is set or cleared according to the settings of
the COM11 and COM10 bits in the Timer/Counter1 Control Register (TCCR1). Refer to
Table 14 for details.
Table 13. Timer TOP Values and PWM Frequency
Note:
Bit
$27 ($47)
$26 ($46)
Read/Write
Initial Value
PWM Resolution
1. If the Compare Register contains the TOP value and the prescaler is not in use
(CS12..CS10 = 001), the PWM output will not produce any pulse at all, because the
up-counting and down-counting values are reached simultaneously. When the pres-
caler is in use (CS12..CS10 ≠ 001 or 000), the PWM output goes active when the
counter reaches the TOP value, but the down-counting compare match is not inter-
preted to be reached before the next time the counter reaches the TOP value,
making a one-period PWM pulse.
10-bit
8-bit
9-bit
MSB
15
R
R
7
0
0
14
R
R
6
0
0
13
R
R
5
0
0
12
R
R
4
0
0
Timer TOP Value
$03FF(1023)
$00FF (255)
$01FF (511)
11
R
R
3
0
0
(1)
10
R
R
2
0
0
AT90S/LS4433
R
R
9
1
0
0
Frequency
f
f
f
TCK1
TCK1
TCK1
/510
/1022
/2046
LSB
R
R
8
0
0
0
ICR1H
ICR1L
41