lpc1759 NXP Semiconductors, lpc1759 Datasheet - Page 48

no-image

lpc1759

Manufacturer Part Number
lpc1759
Description
Lpc17xx Device Highlight
Manufacturer
NXP Semiconductors
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
lpc1759FBD
Manufacturer:
SANYO
Quantity:
2 000
Part Number:
lpc1759FBD80
Manufacturer:
MICROCHIP
Quantity:
12 000
Part Number:
lpc1759FBD80
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
lpc1759FBD80
0
Part Number:
lpc1759FBD80,551
Manufacturer:
LT
Quantity:
375
Part Number:
lpc1759FBD80,551
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
lpc1759FBD80,551
Manufacturer:
NXP/恩智浦
Quantity:
20 000
NXP Semiconductors
LPC1759_58_56_54_52_51_4
Product data sheet
11.5 I
Table 11.
T
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
Symbol
f
t
t
t
t
t
2
amb
SCL
f
LOW
HIGH
HD;DAT
SU;DAT
C-bus
See the I
Parameters are valid over operating temperature range unless otherwise specified.
t
and the acknowledge.
A device must internally provide a hold time of at least 300 ns for the SDA signal (with respect to the
V
C
The maximum t
output stage t
SDA and the SCL pins and the SDA/SCL bus lines without exceeding the maximum specified t
In Fast-mode Plus, fall time is specified the same for both output stage and bus timing. If series resistors
are used, designers should allow for this when considering bus timing.
The maximum t
the maximum of t
maximum must only be met if the device does not stretch the LOW period (t
clock stretches the SCL, the data must be valid by the set-up time before it releases the clock.
t
transmission and the acknowledge.
HD;DAT
SU;DAT
=
IH
b
= total capacitance of one bus line in pF.
(min) of the SCL signal) to bridge the undefined region of the falling edge of SCL.
40
is the data hold time that is measured from the falling edge of SCL; applies to data in transmission
is the data set-up time that is measured with respect to the rising edge of SCL; applies to data in
°
Dynamic characteristic: I
C to +85
2
C-bus specification UM10204 for details.
Parameter
SCL clock
frequency
fall time
LOW period of
the SCL clock
HIGH period of
the SCL clock
data hold time
data set-up
time
f
All information provided in this document is subject to legal disclaimers.
is specified at 250 ns. This allows series protection resistors to be connected in between the
HD;DAT
f
for the SDA and SCL bus lines is specified at 300 ns. The maximum fall time for the SDA
VD;DAT
°
C.
could be 3.45 μs and 0.9 μs for Standard-mode and Fast-mode but must be less than
[2]
Rev. 04.02 — 1 April 2010
or t
VD;ACK
[4][5][6][7]
[3][4][8]
[9]
by a transition time (see the I
2
C-bus pins
Conditions
Standard-mode
Fast-mode
of both SDA and
SCL signals
Standard-mode
Fast-mode
Standard-mode
Fast-mode
Standard-mode
Fast-mode
Standard-mode
Fast-mode
Standard-mode
Fast-mode
LPC1759/58/56/54/52/51
[1]
32-bit ARM Cortex-M3 microcontroller
2
C-bus specification UM10204). This
Min
0
0
-
20 + 0.1 × C
4.7
1.3
4.0
0.6
0
0
250
100
LOW
b
) of the SCL signal. If the
© NXP B.V. 2010. All rights reserved.
Max
100
400
300
300
-
-
-
-
-
-
-
-
f
.
Unit
kHz
kHz
ns
ns
μs
μs
μs
μs
μs
μs
ns
ns
48 of 74