mpu-360f MicroPower Direct, LLC, mpu-360f Datasheet

no-image

mpu-360f

Manufacturer Part Number
mpu-360f
Description
Compact U-channel, 360w Power Factor Corrected, Ac/dc Power Supplies
Manufacturer
MicroPower Direct, LLC
Datasheet
MPU-360F
Key Features:
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Compact U-Channel, 360W
Power Factor Corrected,
AC/DC Power Supplies
360W Output Power
Universal 90-264 AC Input
Built-In DC Fan (End)
Active PFC = >0.99
EN 60950 Approved
Low Leakage Current
Four Single Output Models
Meets EN 55022 B
>120 kHour MTBF
Only 7.8” x 3.2” x 1.57”
Electrical Specifi cations
Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice.
Parameter
Output Voltage/Current
Minimum Load
Output Voltage Tolerance
Line Regulation
Load Regulation
Ripple & Noise (20 MHz), See Note 2
Hold-Up Time
Temperature Coeffi cient
Short Circuit Protection
Over Voltage Protection
Overload Protection
Input
Parameter
Input Voltage Range
Input Frequency
Input Filter
Input Current
Inrush Current, <2 mS
Safety Ground Leakage Current
Power Factor Correction, See Note 1
Output
General
Parameter
Isolation Voltage
Isolation resistance
Isolation Capacitance
EMI/RFI
EMC Compliance
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Size
Weight
Reliability Specifi cations
Parameter
MTBF
Safety Standards
Vibration
www.micropowerdirect.com
Series
Electrical Fast Transients/Bursts On Mains
10~500 Hz, 5G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis
MIL HDBK 217F, 25°C, Gnd Benign
Electrostatic Discharge (ESD)
Conditions
Conditions
Conditions
Conditions
Conditions
24, 36, 48 VDC Output
RF Field Susceptibility
RH, Non-condensing
Cold Start, 115 VAC
Cold Start, 230 VAC
Free Air Convection (See Derating Curve)
Iout = 5% to 100%
Meets EN 55022 Class B; FCC Class B
Output to Ground
Vin = Min to Max
Input to Ground
264 VAC, 63 Hz
Input to Output
UL 1950, EN 60950, IEC 60950
12 VDC Output
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
Continuous (Autorecovery)
Conducted
7.78 x 3.2 x 1.57 Inches (197.7 x 81.3 x 40.0 mm)
See Note 3
Universal
500 VDC
115 VAC
230 VAC
115 VAC
Ambient
Surge
Fixed
3,000
1,500
Min.
Min.
Min.
Min.
Min.
0.99
0.93
120
130
500
-10
-25
0.0
90
47
12
50
IEC/EN 61000-4-2, -6, -8, -11
EN 55022; EN 61000-3-2, -3
±0.03
4,700
Typ.
Typ.
±2.0
±1.0
±1.0
Typ.
Typ.
Typ.
100
+25
75
Max.
Max.
Max.
Max.
Max.
30.0
60.0
IEC/EN 61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
264
370
150
200
150
+70
+85
26.3 Oz (0.746 kg)
0.3
63
95
mV P - P
kHours
mSec
Units
W/VA
Units
%/°C
Units
Units
Units
VDC
A Pk
VAC
VAC
kHz
M
mA
Hz
pF
°C
°C
%
%
%
%
%
%

Related parts for mpu-360f

mpu-360f Summary of contents

Page 1

... MPU-360F Compact U-Channel, 360W Power Factor Corrected, AC/DC Power Supplies Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice. Key Features: Input • 360W Output Power Parameter • ...

Page 2

... MPU-360S-48T(A)F 4.0 2.0 For a 360W unit with a cover and top fan, see the MPU-360E datasheet; For a unit without a cover or fan, see the MPU-360 datasheet Notes: 1. PFC meets EN61000-3-2. 2. Ripple and noise is measured at 20 MHz bandwidth using a 0.1 µF and a 47 µF capacitor connected in parallel as close to the power supply terminals as possible. 3. Overload protection is provided by a “ ...