xe0055cs2 ETC-unknow, xe0055cs2 Datasheet
xe0055cs2
Related parts for xe0055cs2
xe0055cs2 Summary of contents
Page 1
... The XE0055CS2 complies with FCC Part 68 Rules simpli- fying certification of the completed system. The XE0055CS2 is a low power design operating from a single +5 volt power supply. As with all Xecom tele- phone interface modules, internal ring indication and switch hook are provided to establish the telephone line connection ...
Page 2
... XE0055CS2 Mechanical Specifications Inches Millimeters Dim Min Max Min A 0.290 0.310 7.37 B 0.490 0.510 12.45 12.95 C 1.990 2.010 50.55 51.05 D 0.040 0.060 1.02 E 1.390 1.410 35.31 35.81 F 0.090 0.110 2.29 G 0.790 0.810 20.07 20.57 H 0.125 0.200 3.18 I 0.022 0.028 0.56 J 0.490 0.510 12.45 12.95 ABSOLUTE MAXIMUM RATINGS Storage Temperature Operating Temperature Range Maximum Lead Temperature (soldering 2 seconds per wave) Note: The XE0204 is available with an extended operating temperature range of -40C to +85C ...
Page 3
... Hook-switch relay control input. A high on OH closes the internal relay and con- nects the equipment to the telephone line connects directly to the secondary side of the XE0055CS2 telephone line trans- former. 5 GND This pin is used as common reference for all of the control signals in the XE0055CS2 ...
Page 4
... XE0055CS2 Electrical Specification Parameter Power Supply Current Off Hook, 5.0 Volts Transmit Insertion loss 600 Ohm Impedence, 1000 Hz Receive Insertion loss 600 Ohm Impedance, 1000 Hz Line Impedance At 1000 Hz, Rm 340 ohms Coupler Match Input Input impedance to T1 & T2 impedance Ring Detect Sensitivity Min. AC voltage between Tip & ...
Page 5
... XE0055CS2 circuitry. Xecom recommends the Teccor P3100 Sidactor for this function. Its typical breakover voltage of 310 volts prevents the XE0055CS2 from being exposed to voltage surges while being rated high enough to prevent being triggered by an incoming Ring signal. ...
Page 6
... If the system is capable of DTMF dialing, the maximum DTMF transmission level must be less than 0 dBm averaged over a 3 second interval. 4. Billing Delay A delay of 2 seconds or greater is required after the time the XE0055CS2 is taken “off hook” and before any information is transmitted. This is required to ensure that billing information may be exchanged between telephone company central offices without interference. ...
Page 7
... Xecom reserves the right to modify specifications and/or prices without notice. Product mentioned herein are used for identification purposes only and may be trade- marks and/or registered trademarks of their respective companies. XECOM Xecom Incorporated 374 Turquoise Street, Milpitas, CA 95035 Ph:408-945-6640 Fax:408-942-1346 Email: info@xecom.com (7) XE0055CS2 ...