zicm0868p0 California Eastern Laboratories, zicm0868p0 Datasheet

no-image

zicm0868p0

Manufacturer Part Number
zicm0868p0
Description
868 / 900 Mhz System-on-chip Soc Based Modules
Manufacturer
California Eastern Laboratories
Datasheet
DESCRIPTION
CEL's MeshConnect™ Sub-G modules are built on the Si1000
and Si1002 highly integrated wireless SoC's from Silicon Labs.
Targeting dense operating environments, CEL’s MeshConnect
Sub-G modules deliver superior range and performance. Their
low power consumption enables longer battery life and their link
budgets provide reliable transmission in non line of sight ap-
plications such as lighting control, industrial sensor networks,
serial wire replacement, metering, irrigation and more. At +13
and +20 dBm power outputs, the new Sub-G modules offer 868
MHz (Europe) and 915 MHz (Americas) ISM band options. As
certified and qualified modules, the MeshConnect Sub-G solu-
tions eliminate the need for costly certifications, reducing overall
system cost and accelerating time to market.
APPLICATIONS
• Lighting Control
• Irrigation
• Serial wire replacement
• Industrial Sensor Networks
• Wireless M-Bus Metering
• Home Automation & Smart Plugs
• Security
• And more...
The information in this document is subject to change without notice, please confirm data is current
Document No: 0009-00-07-00-000 (Issue ES)
Date Published: April 5, 2011
868 / 900 MHz System-on-Chip (SoC) Based Modules
PRELIMINARY DATA SHEET
MeshConnect™ Sub-G Module Series
ZICM0868P0-KIT1-1 and ZICM0900P2-KIT1-1
FEATURES
• Frequency Range:
• Link Budget up to -140 dB
• Max Output Power:
• Data Rate: 0.123 to 150 kbps
• General Purpose I/Os: 21
• High Speed 8051 MCU:
• 10-Bit ADC:
• Serial Communication:
• Add 1MB additional Flash memory
902- 928 MHz
868 MHz
(for +20 dBm module)
Sensitivity up to -121 dBm
+20 dBm and +13 dBm available
output powers
+ 13 dBm @ 3.6 V
+ 20 dBm @ 3.6 V
25 MHz - single cycle instruction execution
4kB RAM / 64 kB Flash
300 ksps, 18-ch inputs
UARTs, SPI (Master/Slave)
SMBus, PCA
to enable Over The Air (OTA)
programming
• Long Range
• Low Power Consumption
• 868 and 900 MHz Frequency Ranges
• 1MB additional Flash Memory option enables
Over the Air (OTA) Programming
ZICM0868P0
(Optional)
DC
DC
MeshConnect
(ZICM0868P0)
Development Kits Available:
(ZICM0900P2)
• Modulation:
• RF Power Consumption
• Sleep Current 1.2 µA TYP
• Up to 6 miles of range
• Operating Temperature Range:
•Software Platforms:
• FCC, CE and IC certifications in
• ROHS compliant
FSK, GFSK, OOK
24 mA Receive
18 mA @ + 1 dBm transmit
42 mA @ + 13 dBm transmit
97 mA @ + 19 dBm transmit
(line of sight)
-40 to +85ºC
Synapse SNAP Embedded Firmware
Wireless M-Bus (868 MHz Only)
CEL Application Programming
Interface (API)
Silicon Labs EZMac
Progress
Multiple antenna options
FSK Modulation Only
Sub-G Modules
ZICM0868P0
ZICM0900P2
ZICM0900P2
Page 1

Related parts for zicm0868p0

zicm0868p0 Summary of contents

Page 1

... Document No: 0009-00-07-00-000 (Issue ES) Date Published: April 5, 2011 PRELIMINARY DATA SHEET MeshConnect™ Sub-G Module Series 868 / 900 MHz System-on-Chip (SoC) Based Modules ZICM0868P0-KIT1-1 and ZICM0900P2-KIT1-1 MeshConnect ZICM0868P0 • Long Range • Low Power Consumption • 868 and 900 MHz Frequency Ranges • ...

Page 2

... ZICM0900P2-1C MeshConnect™ ZICM0900P2-1CU-SN Sub-G Module (902-928 MHz) ZICM0900P2-1CS-SN ZICM0900P2-1C-SN ZICM0868P0-KIT1-1 MeshConnect™ Sub-G Development Kits ZICM0900P2-KIT1-1 MeshConnect™ Sub-G Module Series Description 868 MHz Module, +13dBm SoC with U.FL connector for external antenna 868 MHz Module, +13dBm SoC with RP-SMA connector for external antenna 868 MHz Module, +13dBm SoC with 1/4 wave wire antenna 900 MHz Module, +20dBm SoC with U ...

Page 3

... For more detail information regarding MeshConnect Development Kits, refer to the respective development kit user guides documents. (Available at CEL’s website: www.cel.com/MeshConnect) DEVELOPMENT KIT ORDERING INFORMATION Part Number Order Number ZICM0868P0-KIT1-1 MeshConnect™ Sub-G Development Kits ZICM0900P2-KIT1-1 MeshConnect™ Sub-G Module Series ANT MeshConnect ...

Page 4

TABLE OF CONTENTS Introduction and Overview Description.............................................................................................................................................................................................. Features.................................................................................................................................................................................................. Applications............................................................................................................................................................................................ Ordering Information............................................................................................................................................................................. Module Block Diagram........................................................................................................................................................................... Development Kit..................................................................................................................................................................................... System Level Function Transceiver IC......................................................................................................................................................................................... Antenna................................................................................................................................................................................................... Additional Flash Memory....................................................................................................................................................................... Electrical Specification Absolute Maximum Ratings................................................................................................................................................................... Recommended (Operating Condition).................................................................................................................................................. DC Characteristics.................................................................................................................................................................................. RF Characteristics.................................................................................................................................................................................. Pin Signal & Interfaces Pin Signals I/O Configuration................................................................................................................................................................ I/O Pin Assignment................................................................................................................................................................................. ...

Page 5

TRANSCEIVER IC The MeshConnect Sub-G modules are based on the Silicon Labs Si1000 and Si1002 wireless SoCs ICs. These devices incorporate the RF transceiver with the baseband modem, a hardwired MAC, and an embedded 8051 microcontroller, offering a high performance ...

Page 6

... MeshConnect™ Sub-G Module Min Typ Max 1.8/2.7* 3.3 3.6 865 – 870 902 – 928 - 3.6V, ZICM0868P0 TX power max) DD MeshConnect™ Sub-G Module Min Typ Max – 42 – – 24 – – 1.2 – = 3.6V, ZCM0900P2 TX power max) DD MeshConnect™ Sub-G Module Min ...

Page 7

... RF Frequency Range Transmitter Maximum Output Power Minimum Output Power FSK Error Deviation Receiver Sensitivity (1% PER, 150kbps) Sensitivity (1% PER, 2kbps) Saturation (maximum input level) MeshConnect™ Sub-G Module Series = 3.6V, ZICM0868P0) DD MeshConnect™ Sub-G Module Min Typ Max 865 – 870 – 13 – ...

Page 8

PIN SIGNALS I/O PORT CONFIGURATION MeshConnect module has 56 edge I/O interfaces for connection to the user’s host board. shows the layout of the 56 edge castellations. MeshConnect I/O PIN ASSIGNMENTS Number Name 1 GND 2 GND 3 GND 4 ...

Page 9

MeshConnect I/O PIN ASSIGNMENTS Number Name GND 38 GND 39 GND 40 GND 41 GND 42 P2.2 GPIO connected to LED2 on CEL Eval board 43 P2.1 GPIO connected to Switch 1 on CEL Eval ...

Page 10

SOFTWARE/FIRMWARE (Continued) • Self Healing (Orphan handling) • Point-to-Point network formation • Point-to-Multipoint (Star) network formation • Mesh network formation* • ACK • Wakeup Modes (Si100X) • Frequency Hopping • Unicast Addressing using 16-bit device IDs • Broadcast Addressing • ...

Page 11

MODULE LAND FOOTPRINT Note: Unless otherwise specified. Dimensions are in Inches [mm]. 1.413 1.300 1.200 1.100 1.021 1.005 1 .0.150 Ø 0.065 19 0.050 0.000 20 EVALUATION BOARD CEL provides an Evaluation board to allow easy testing of the Module. ...

Page 12

PROCESSING Recommended Reflow Profile Parameters Values Ramp up rate (from Tsoakmax to Tpeak) Minimum Soak Temperature Maximum Soak Temperature Soak Time TLiquidus Time above TL Tpeak Time within 5º of Tpeak Time from 25º to Tpeak Ramp down rate Pb-Free Solder Paste ...

Page 13

PROCESSING (Continued) Hand Soldering Hand soldering is possible. When using a soldering iron, follow IPC recommendations (reference document IPC-7711) Rework The MeshConnect Module can be unsoldered from the host board. Use of a hot air rework tool should be programmable ...

Page 14

... Health Canada limits for the general population. Consult Safety Code 6, obtainable from Health Canada's website: http://www.hc-sc.gc.ca/ewh-semt/pubs/radiation/99ehd-dhm237/index-eng.php CE Certification — Europe ZICM0868P0 (PENDING) The MeshConnect 868MHz RF modules will be tested and certified for use in the European Union. OEM Responsibility to the European Union Compliance Rules If the MeshConnect module incorporated into a product, the OEM must verify compliance of the final product to the European Harmonized EMC and Low-Voltage / Safety Standards ...

Page 15

SHIPMENT, HANDLING, AND STORAGE Shipment The MeshConnect Modules are delivered in trays of 28. Handling The MeshConnect Modules are designed and packaged to be processed in an automated assembly line. Warning The MeshConnect Modules contain highly sensitive electronic circuitry. Handling ...

Page 16

REFERENCES & REVISION HISTORY Previous Versions Changes to Current Version 0008-00-07-00-000 Initial preliminary datasheet. (Issue ES) April 5, 2011 Disclaimer • The information in this document is current as of the published date. The information is subject to change without notice. For actual ...

Related keywords