hcts190ms Intersil Corporation, hcts190ms Datasheet

no-image

hcts190ms

Manufacturer Part Number
hcts190ms
Description
Radiation Hardened Synchronous 4-bit Up/down Counter
Manufacturer
Intersil Corporation
Datasheet
September 1995
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures.
1-888-INTERSIL or 321-724-7143 | Copyright © Intersil Corporation 1999
Features
• 3 Micron Radiation Hardened CMOS SOS
• Total Dose 200K RAD (Si)
• SEP Effective LET No Upsets: >100 MEV-cm
• Single Event Upset (SEU) Immunity < 2 x 10
• Dose Rate Survivability: >1 x 10
• Dose Rate Upset >10
• Latch-Up Free Under Any Conditions
• Fanout (Over Temperature Range)
• Military Temperature Range: -55
• Significant Power Reduction Compared to LSTTL ICs
• DC Operating Voltage Range: 4.5V to 5.5V
• LSTTL Input Compatibility
• Input Current Levels Ii
Ordering Information
Pinouts
HCTS190DMSR
HCTS190KMSR
HCTS190D/Sample
HCTS190K/Sample
HCTS190HMSR
16 LEAD CERAMIC DUAL-IN-LINE METAL SEAL PACKAGE
Bit-Day (Typ)
- Standard Outputs - 10 LSTTL Loads
- VIL = 0.8V Max
- VIH = VCC/2 Min
(SBDIP) MIL-STD-1835 CDIP2-T16, LEAD FINISH C
PART NUMBER
GND
U/D
CE
Q1
Q0
Q2
Q3
P1
1
2
3
4
5
6
7
8
10
TOP VIEW
RAD (Si)/s 20ns Pulse
5 A @ VOL, VOH
TEMPERATURE RANGE
12
o
16
15
14
13
12
11
10
9
C to +125
RAD (Si)/s
-55
-55
P0
CP
RC
TC
PL
P2
P3
VCC
o
o
C to +125
C to +125
+25
+25
+25
o
o
o
o
C
C
C
C
2
/mg
-9
o
o
C
C
Errors/
1
Description
The Intersil HCTS190MS is an asynchronously presettable
BCD Decade synchronous counter. Presetting the counter to
the number on the preset data inputs (P0 - P3) is accom-
plished by a low on the parallel load input (PL). Counting
occurs when (PL) is high, Count Enable (CE) is low and the
Up/Down (U/D) input is either low for up-counting or high for
down-counting. The counter is incremented or decremented
synchronously with the low-to-high transition of the clock.
When an overflow or underflow of the counter occurs, the
Terminal Count output (TC), which is low during counting,
goes high and remains high for one clock cycle. This output
can be used for look-ahead carry in high speed cascading.
The TC output also initiates the Ripple Clock output (RC)
which, normally high, goes low and remains low for the low-
level portion of the clock pulse. These counter can be cas-
caded using the Ripple Carry output.
If the decade counter is preset to an illegal state or assumes
an illegal state when power is applied, it will return to the
normal sequence in one or two counts
The HCTS190MS utilizes advanced CMOS/SOS technology
to achieve high-speed operation. This device is a member of
radiation hardened, high-speed, CMOS/SOS Logic Family.
The HCTS190MS is supplied in a 16 lead Ceramic flatpack
(K suffix) or a SBDIP Package (D suffix).
Intersil Class S Equivalent
Intersil Class S Equivalent
Sample
Sample
Die
HCTS190MS
Synchronous 4-Bit Up/Down Counter
16 LEAD CERAMIC METAL SEAL FLATPACK PACKAGE
GND
(FLATPACK) MIL-STD-1835 CDFP4-F16, LEAD FINISH C
SCREENING LEVEL
U/D
CE
Q1
Q0
Q2
Q3
P1
1
2
3
4
5
6
7
8
TOP VIEW
Radiation Hardened
16 Lead SBDIP
16 Lead Ceramic Flatpack
16 Lead SBDIP
16 Lead Ceramic Flatpack
Die
16
15
14
13
12
11
10
9
Spec Number
File Number
PACKAGE
P0
CP
RC
TC
PL
P2
P3
VCC
518614
2474.2

Related parts for hcts190ms

hcts190ms Summary of contents

Page 1

... The HCTS190MS utilizes advanced CMOS/SOS technology to achieve high-speed operation. This device is a member of radiation hardened, high-speed, CMOS/SOS Logic Family. The HCTS190MS is supplied lead Ceramic flatpack (K suffi SBDIP Package (D suffix). SCREENING LEVEL o o ...

Page 2

... FF0 FUNCTION Count Up Count Down Asynchronous Preset No Change H = High Level L = Low Level X = Immaterial = Transition from low to high NOTE: U should be changed only when clock is high. HCTS190MS FF1 FF2 TRUTH TABLE P ...

Page 3

... VCC = 4.5V, VIH = 2.25V, Functional Test VIL = 0.8V (Note 2) NOTES: 1. All voltages reference to device GND. 2. For functional tests VO 4.0V is recognized as a logic “1”, and VO Specifications HCTS190MS Reliability Information Thermal Resistance SBDIP Package 10mA Ceramic Flatpack Package . . . . . . . . . . . 25mA Maximum Package Power Dissipation at +125 SBDIP Package ...

Page 4

... U TPLH VCC = 4.5V TPHL VCC = 4. TPLH VCC = 4.5V TPHL VCC = 4.5V NOTES: 1. All voltages referenced to device GND measurements assume RL = 500 , CL = 50pF, Input 3ns, VIL = GND, VIH = 3V. Specifications HCTS190MS GROUP (NOTES SUB- CONDITIONS GROUPS TEMPERATURE 10, 11 ...

Page 5

... Quiescent Current ICC VCC = 5.5V, VIN = VCC or GND Output Current (Sink) IOL VCC = 4.5V, VIN = VCC or GND, VOUT = 0.4V Output Current IOH VCC = 4.5V, VIN = VCC or GND, (Source) VOUT = VCC -0.4V Specifications HCTS190MS (NOTE 1) CONDITIONS TEMPERATURE VCC = 5.0V 1MHz +125 VCC = 5.0V 1MHz +125 VCC = 4.5V +125 VCC = 4.5V +125 VCC = 4 ...

Page 6

... AC measurements assume RL = 500 , CL = 50pF, Input 3ns, VIL = GND, VIH = 3V. 3. For functional tests VO 4.0V is recognized as a logic “1”, and VO TABLE 5. BURN-IN AND OPERATING LIFE TEST, DELTA PARAMETERS (+25 PARAMETER ICC IOL/IOH Specifications HCTS190MS (NOTES 1, 2) CONDITIONS TEMPERATURE 0.5V is recognized as a logic “0”. GROUP B SUBGROUP ...

Page 7

... Each pin except VCC and GND will have a resistor of 1K OPEN 12, 13 NOTE: Each pin except VCC and GND will have a resistor of 47K Group E, Subgroup 2, sample size is 4 dice/wafer 0 failures. Specifications HCTS190MS TABLE 6. APPLICABLE SUBGROUPS METHOD GROUP A SUBGROUPS 100%/5004 ...

Page 8

... Variables Data (All Delta operations). Data is identified by serial number. Data header includes lot number and date of test. • The Certificate of Conformance is a part of the shipping invoice and is not part of the Data Book. The Certificate of Conformance is signed by an authorized Quality Representative. HCTS190MS 100% Interim Electrical Test 1 (T1) 100% Delta Calculation (T0-T1) 100% Static Burn-In 2, Condition hrs ...

Page 9

... For information regarding Intersil Corporation and its products, see web site http://www.intersil.com Sales Office Headquarters NORTH AMERICA Intersil Corporation P. O. Box 883, Mail Stop 53-204 Melbourne, FL 32902 TEL: (321) 724-7000 FAX: (321) 724-7240 HCTS190MS AC Load Circuit DUT TPHL CL = 50pF RL = 500 TTHL 80% ...

Page 10

... Q0 (3) CE (4) U/D (5) Q2 (6) Q3 (7) NOTE: The die diagram is a generic plot form a similar HCS device intended to indicate approximate die size and bond pad location. The mask series for the HCTS190 is TA14444A. HCTS190MS HCTS190MS 10 (15) P0 (14) CP (13) RC (12) TC (11) PL 518614 Spec Number ...

Related keywords