gld150 SL Power Electronics, gld150 Datasheet

no-image

gld150

Manufacturer Part Number
gld150
Description
Gld150 Gold Performance Medical Switchers 150 Watt Single Output
Manufacturer
SL Power Electronics
Datasheet
60
GLD150 Gold Performance Medical Switchers
150 Watt Single Output
SPECIFICATIONS:
Ac Input
85-264 Vac, 47-63 Hz single phase.
Input Current
2.8 A line current maximum, at 90 Vac, 60 Hz with full rated load,
power factor .99 typical, .96 minimum. Input current harmonic
content meets the requirements of IEC1000-3-2.
Output Power
150 W with convection cooling, 180 W with fan cooling.
Efficiency
Minimum 80% at full rated load with 230 Vac Input. Approximately
3% less at 115 Vac.
Hold-Up Time
Outputs will remain within regulation limits for 25 ms minimum from
loss of ac input at full load, 10 ms before Power Fail indication.
Dc Ouput
Total regulation is the maximum deviation from the nominal voltage
for all steady state loading conditions. Peak ratings are for 60 s
maximum duration, 10% duty cycle.
Overload Protection
Fully protected against short circuit and output overload. Short
circuit protection is cycling type power limit.
Minimum Load
No minimum load required to maintain output specifications.
Output Noise
0.5% rms, 1% pk-pk, 20 MHz Bandwidth, differential mode.
Measured with noise probe directly across output terminals of the
power supply.
Transient Response
Main Output - 500 µs typical response time for return to within
0.5% of final value for a 50% load step change, Di/Dt< 0.2 A µs.
Maximum voltage deviation is 3%.
Remote Sense
Provided as a standard feature on all models.
Overvoltage Protection
Built in on all models.
Input Protection
Internal ac fuses provided on both lines on all units.
Voltage Adjustment
Output Voltage is adjustable +/- 5% with user adjustable potentiometer.
Temperature Coefficient
0.03% / °C typical on all outputs.
Overshoot
Less than 2% overshoot at turn-on under all conditions, less than
1% overshoot at turn-off under all conditions.
Inhibit
Inhibit signal is pulled to the V1 output common to reduce average
output voltage to less than 5% of nominal.
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033
800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com
FEATURES:
• Compact 4.5” x 7” x 1.7” size
• Power factor corrected to IEC 1000-3-2 Class A
• Less than 300 µA leakage
• EMI compliance to CISPR11, FCC Class B
• Power fail and remote sense standard
• Medical Approved to UL2601-1, IEC601-1/60601-1
• 2 year warranty
EMI/EMC Compliance
All models include built-in EMI filtering to meet the EMC require-
ments of IEC601-1. Unless otherwise stated, all tests are done
at full load and 115 and 230 Vac input.
Conducted Emissions
Static Discharge
RF Field Susceptibility
Fast Transients / Bursts
Surge Susceptibility
Conducted RF Susceptibility EN61000-4-6, 3V
Voltage Sags & Surges
Inrush Current
Inrush 240 Vac is less than 37 A, averaged over the first ac half-
cycle under cold start conditions. Limiting provided by internal
thermistors.
Fan Output
An additional 12 Vdc, 250 mA output suitable for powering a dc
fan is included in all models. The fan output is both current limited
and thermally protected.
Thermal Shutdown
Provided as a standard feature. Designed to protect unit from
prolonged over temperature.
Power Fail
TTL / CMOS compatible output goes low (<0.5 V) 8 ms before
output voltage drops more than 4% below nominal voltage upon
loss of ac power.
Power Good
TTL / CMOS compatible output goes high more than 100 ms
after V1 reaches regulation and should assure that sufficient
energy is stored in the input section to provide normal power
fail/shutdown.
Medical Approvals
All models are Certified to be in compliance with the
applicable requirements of UL2601-1, CSA-C22.2 No. 601.1,
IEC601-1/60601-1.
Leakage Current
70 µA, 132 Vac @ 60 Hz normal conditions. Single fault condi-
tions, 130 µA, 254 Vac @ 50 Hz.
Design Verification Documents
The “Gold” series has undergone rigorous review and design
analysis. The following product documentation is available upon
request;
1. MTBF study
2. DVT Data
3. EMC / Susceptibility test results
and CSA-C22.2 No. 601.1
marked to LVD
EN61000-4-4, 2 kV, 5 kHz
EN55011, Class B; FCC Class B
EN61000-4-2, 6 kV contact 8 kV air
EN61000-4-3, 3V/meter
EN61000-4-5, 1 kV diff., 2 kV com.
EN61000-4-11

Related parts for gld150

gld150 Summary of contents

Page 1

... GLD150 Gold Performance Medical Switchers 150 Watt Single Output SPECIFICATIONS: Ac Input 85-264 Vac, 47-63 Hz single phase. Input Current 2.8 A line current maximum Vac with full rated load, power factor .99 typical, .96 minimum. Input current harmonic content meets the requirements of IEC1000-3-2. Output Power 150 W with convection cooling, 180 W with fan cooling ...