cpa200-4530 Power-One, cpa200-4530 Datasheet

no-image

cpa200-4530

Manufacturer Part Number
cpa200-4530
Description
200
Manufacturer
Power-One
Datasheet
Description
The CPA and CPD Series are highly reliable power supplies
for CompactPCI
communications, industrial, military, aerospace, and other
applications. These power supplies offer high power density
in plug-in modules that meet the requirements of the
PICMG
systems.
The converters use the patented EDGE
provide important advantages such as flexible output
power, extremely high efficiency, excellent reliability, full
input-to-output isolation, negligible inrush current, hot-swap
capability, soft start, and overtemperature protection.
The input is protected by a transient suppressor (varistor)
against surges and transients occurring on the source lines
and cover an operating input voltage range from either 90 to
264 VAC or 36 to 75 VDC.
The outputs are protected against continuous overload,
open-circuit, and short-circuit. Full n+1 redundant operating
mode is made possible by integrated ORing FETs or ORing
Table of Contents
Description ....................................................................... 1
Model Selection ............................................................... 2
Functional Description ..................................................... 3
Electrical Input Data ......................................................... 5
Electrical Output Data ...................................................... 7
Auxiliary Functions ......................................................... 10
BCD20005-G Rev. AF, 18-Aug-10
®
power interface specification for CompactPCI
®
systems, which are increasingly used in
®
200 – 550 Watt CompactPCI
TM
40.4
1.6"
8 HP
technology and
162.5
6.4"
Page
Page 1 of 19
233.3
7.8"
6 U
®
Features
Electromagnetic Compatibility (EMC) ............................ 13
Immunity to Environmental Conditions .......................... 15
Mechanical Data ............................................................ 16
Safety and Installation Instructions ................................ 17
Options ........................................................................... 19
• RoHS lead-free-solder and lead-solder-exempted
• Compliant with PICMG
• Wide range DC or AC input with PFC
• Extremely high efficiency and high power density
• Low inrush current
• 4 high current outputs with flexible load distribution
• Integrated ORing FETs / diodes for true redundancy
• Inhibit and enable inputs
• Remote sense lines
• Single-wire current share function for 3 outputs
• Hot-swap capability
• 47-pin connector, type Positronic
• Overtemperature, overvoltage, overcurrent, and
products are available
overpower protection
Safety according to IEC/EN 60950-1 2
UL/CSA 60950-1 2
®
AC-DC and DC-DC Converters
CPA, CPD Series Data Sheet
nd
Ed.
®
CompactPCI
40.6
1.6"
8 HP
www.power-one.com
®
nd
specifications
162.5
6.4"
Ed. and
100
3.94"
3 U
Page

Related parts for cpa200-4530

cpa200-4530 Summary of contents

Page 1

... UL/CSA 60950-1 2 Page Electromagnetic Compatibility (EMC) ............................ 13 Immunity to Environmental Conditions .......................... 15 Mechanical Data ............................................................ 16 Safety and Installation Instructions ................................ 17 Options ........................................................................... 19 Page CPA, CPD Series Data Sheet AC-DC and DC-DC Converters 162.5 40.6 6.4" 1.6" ® ® CompactPCI specifications nd Ed. and nd Ed. www.power-one.com 100 3.94" Page ...

Page 2

... V o nom [V] CPD200-4530 Vo1 5.0 Vo2 3.3 Vo3 12 Vo4 –12 CPD250-4530 Vo1 5.0 Vo2 3.3 Vo3 12 Vo4 –12 CPD500-4530G Vo1 5.0 Vo2 3.3 Vo3 12 Vo4 –12 CPA200-4530 Vo1 5.0 Vo2 3.3 Vo3 12 Vo4 –12 CPA250-4530 Vo1 5.0 Vo2 3.3 Vo3 12 Vo4 –12 CPA500-4530 Vo1 5.0 Vo2 3.3 Vo3 12 Vo4 –12 CPA550-4530 Vo1 5.0 Vo2 3 ...

Page 3

... Product Marking Label with specific type designation, applicable safety approvals and recognition marks, CE mark, warnings, Power-One patents, company logo, input voltage range, Functional Description The inputs of all converters are protected against surges and transients occurring on the source lines. A highly efficient input filter and an active inrush current limiter ensure a very low inrush current of short duration ...

Page 4

... Page CPA, CPD Series Data Sheet ® AC-DC and DC-DC Converters JM041 + SBias + JM014a + SBias + C y www.power-one.com ORing + V o1 FET ORing + V o2 FET + ORing V o3 FET ORing V o4 diode + ORing + V o1 FET ORing + V o2 FET + ORing V ...

Page 5

... CPD/CPA250 3 nd First value for CPA500, 2 value for CPA550 4 Short interruption of V without affecting the outputs i 5 CPA200/250 with version V117 or higher, as they are equipped with an input voltage trigger BCD20005-G Rev. AF, 18-Aug-10 CPD200/250 Conditions min typ – ...

Page 6

... CPD500 models start and switch off CPA models exhibit an undervoltage trigger controlling start-up and shutdown. The threshold is between 80 and 90 VAC. See also Power Fail Signal. Note: CPA200/250 with version operated these models have no undervoltage i i min shutdown and will therefore operate with a high input current at full load ...

Page 7

... Watt CompactPCI ® Electrical Output Data General Conditions for table 4: – °C, unless T is specified – CPD/CPA200: 250 LFM (1.25 m/s), CPD/CPA250: 400 LFM (2 m/s) – Sense lines connected directly at the connector Table 4a: Output data of CPD/CPA200 and CPD/CPA250 Output Characteristics Conditions V Output voltage V ...

Page 8

... I no min. load required o 4 120 120 ±10 ±10 3 ±50 – 220 0 0 ±200 ±150 300 300 ±0.3 ±0.5 www.power-one.com Unit max 3.35 VDC ±10 mV ±10 ±150 µs mV/K Unit VDC µs mV/K ...

Page 9

... The thermal conditions are significantly influenced by the input voltage, the output current, the airflow, and the temperature of the adjacent elements and surfaces. T value only 1.0 0.6 0.5 0 Fig. 4a Output power versus temperature T CPA200 1 05186b o max Fig. 4b Output power versus temperature T ...

Page 10

... CPA, CPD Series Data Sheet ® AC-DC and DC-DC Converters . Recommended values: pp ® HC2LP 1 µH / 2.2 µH /24 A. JM010 Vo1SENSE 30 L Vo1 46 1 – 4 Vo2SENSE Vo2 13 – RTN 47 5 – nom 3 Gnd 06155a www.power-one.com ...

Page 11

... nom BCD20005-G Rev. AF, 18-Aug-10 The threshold levels for V CPD models and 80 – 90 VAC for CPA models. Note: CPD200/250 (and CPA200/250 up to version V116) changes from high DEG# provide only the signal FAL#, but the converter is not inhibited. falls C Note remains for typ ...

Page 12

... C C max inh – – min i max max – – max i min i max . inh – – max i min i max nom open = open inh = open inh – max www.power-one.com ...

Page 13

... MHz 900 ±5 MHz positive 60 s negative transients per coupling mode 12 5 pos. and 5 neg. surges per 2 coupling mode 150 0.15 – 80 MHz www.power-one.com In Per- 2 oper. form. yes A yes A yes A yes B yes A ...

Page 14

... Page CPA, CPD Series Data Sheet ® AC-DC and DC-DC Converters CPA500-4530S211 V107 W0622, Vi=230VAC, Ponom, Peak, Phase, Uster, 20-Sep-07 0.2 0 nom and nom o nom EN 55022 A EN 55022 MHz and I o nom EN 55022 A EN 55022 B [MHz] www.power-one.com ...

Page 15

... Shock IEC/EN 60068-2-27 (half-sinusoidal) Eb Bump IEC/EN 60068-2-29 (half-sinusoidal) Fda Random vibration IEC/EN 60068-2-35 wide band, CPD200/250, CPA200/250 reproducibility high IEC/EN 60068-2-35 CPD500, CPA500/550 Drop test Converter in proper packing CPD200/250 1 Version V106 or higher Temperatures Table 10: Temperature specifications, valid for an air pressure of 800 – 1200 hPa (800 – 1200 mbar) ...

Page 16

... Watt CompactPCI ® Mechanical Data Dimensions in mm (inches) Fig. 15 CPA200/250 and CPD200/250. Overall size: 162.5 x 128.7 x 40.6 mm. Weight: 0.8 kg (0.098") Fig. 16 View of the connector Fig. 17 CPD500 and CPA500/550. Overall size: 223.4 x 162.5 x 40.6 mm. Weight: 1.65 kg (0.098") BCD20005-G Rev. AF, 18-Aug-10 Measuring point of the case temperature T 2 ...

Page 17

... Sense return Vo1 current share Vo3 remote sense Do not connect Degrade signal Inhibit Do not connect Vo2 current share Fail signal Do not connect Vo3 current share Chassis ground ACN Pos. DC input Neutral line ACL Neg. DC input Line input (phase) www.power-one.com 5 5 ...

Page 18

... Note: The DC test voltage shall be slowley increased (within several seconds) and maintained for max. 2 seconds. Trigger level 25 µA. Power-One is executing these factory tests with a reasonable margin, to guarantee its repetition. Test with AC is not possible due to the incorporated Y caps. should not be exceeded. ...

Page 19

... C: Protective Lacquer All boards are covered by a protective lacquer. NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc ...