dmc50 Yamatake Corporation, dmc50 Datasheet - Page 23

no-image

dmc50

Manufacturer Part Number
dmc50
Description
Module Type Controller Control Module / Communication Module
Manufacturer
Yamatake Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
dmc501010R
Manufacturer:
PANASONIC
Quantity:
99 000
Part Number:
dmc501010R
Manufacturer:
PANASONIC/松下
Quantity:
20 000
Part Number:
dmc50CS40000M003
Manufacturer:
AZBIL/YAMATAKE
Quantity:
1 000
Part Number:
dmc50ME20000M001
Manufacturer:
AZBIL/YAMATAKE
Quantity:
1 000
(Message string deletion)
(Falling edge detection)
DERIVATE (Derivative)
(Exponential function)
(Up/down counter)
DED (Dead time)
CLK
CU
CD
RESET
LOAD
PV
RUN
DEDTM
IN
IN
NbC
Pos
RUN
XIN
CYCLE XOUT
IN
EXP
derivate
DELETE
CTUD
delete
F_TRIG
f_trig
DED
CTUD
EXPT
expt
E _ OK
OUT
QU
QD
CV
Q
Q
Q
Input parameter
Output parameter
Description
Input parameter
Output parameter
Description
Input parameter
Output parameter
Description
Input parameter
Output parameter
Description
Input parameter
Output parameter
Description
Input parameter
Output parameter
Description
CU: Boolean type, CountUP execution (higher priority than CD) at TRUE and stop at FALSE
CD: Boolean type, Countdown execution at TRUE and stop at FALSE
RESET: Boolean type, Reset command (higher priority than LOAD, CU and CD), CV=0 at TRUE
LOAD: Boolean type, Load command (higher priority than CU and CD), CV=PV at TRUE
PV: Integer type, Counter target value, Must be PV>0
QU: Boolean type, UP-counter end signal, TRUE at CV≥PV
QD: Boolean type, Down-counter end signal, TRUE at CV=0
CV: Integer type, Counter result
Integration of CTU (up-counter) and CTD (down-counter)
RUN: Boolean type, TRUE=Execution, FALSE=Reset
DEDTM: Timer type, Dead time
IN: Real type, Input data
E_OK: Boolean type, TRUE=Normal, FALSE=Error
OUT: Real type, IN after dead time
Outputting of real type data after dead time
IN: Message type, Message string as base
NBC: Integer type, Number of characters to delete, NBC>1
POS: Integer type, location of the delete begin position, POS>1
Q: Message type, Message string modified by deletion
The designated characters are deleted from the message string at the designated location.
RUN: Boolean type, TRUE=Execution, FALSE=Reset
XIN: Real type, Input data
CYCLE: Timer type, Sampling cycle, CYCLE≥cycle time setting
XOUT: Real type, Derivative result, The generation of output XOUT is proportional to the changing rate of input
Derivative of real type data
IN: Real type, Base number
EXP: Integer type, Exponent number
Q: Real type, IN
Exponential operation
CLK: Boolean type
Q: Boolean type, TRUE when CLK is TRUE→FALSE, and FALSE when CLK is other than this.
Falling edge detection of Boolean type data
XIN.
EXP
23