... LAN / WAN • OC-192 • SONET / SDH Description The VS-550 is a SAW based voltage controlled oscillator that operates at the fundamental frequencies of the internal SAW filters. These SAW filters are high-Q quartz devices that enable the circuit to achieve low phase jitter performance over a wide operating temperature range ...
Page 2
... VS-550 Voltage Controlled SAW Oscillator Electrical Performance Parameter Frequency Nominal Frequency Absolute Pull Range Linearity Gain Transfer (See Pg 5) Temperature Stability Transition Time Supply Voltage Current (No Load) Outputs Mid Level Swing Current Rise Time Fall Time Symmetry Spurious Suppression Jitter (See Pg 5) ...
Page 3
... VS-550 Voltage Controlled SAW Oscillator Outline Diagram VS-550-LFF-GNN 8.89±0.15 XXX.XXX-XXX.XXX [0.350±0.006] VI YWW 13.97±0.20 [0.550±0.008] 0.46±0.05 [0.018±0.002] 2.54±0.13 5.08±0.13 [0.100±0.005] [0.200±0.005] Pin Out Pin Symbol 1 V VCSO Control Voltage ...
Page 4
... VS-550 Voltage Controlled SAW Oscillator Absolute Maximum Ratings Parameter Power Supply Input Current Output Current Voltage Control Range Storage Temperature Solder Temperature / Duration Stresses in excess of the absolute maximum ratings can permanently damage the device. Also, exposure to these absolute maximum ratings for extended periods may adversely affect device reliability. Functional operation is not implied at these or any other conditions in excess of those represented in the operational sections of this datasheet ...
Page 5
... VS-550 Voltage Controlled SAW Oscillator Typical Characteristics 800 At Ambient (22.5°C) Typical Gain Transfer @ 622.0800 = +393 ppm/V 600 Typical Gain Transfer @ 644.5313 = +372 ppm/V 400 200 0 -200 -400 -600 -800 0.3 0.6 -95 Typical Calculated Jitter @ Vc = 1.65V -100 SONET OC-48 (12kHz-20MHz) = 0.239 ps-rms; 1.67 ps-pp -105 SONET OC-192 (50kHz-80MHz) = 0.135 ps-rms; 0.95 ps-pp ...
Page 6
... Gross and Fine Leak Resistance to Solvents Handling Precautions Although ESD protection circuitry has been designed into the VS-550 proper precautions should be taken when handling and mounting. VI employs a human body model (HBM) and a charged-device model (CDM) for ESD susceptibility testing and design protection evaluation. ...
Page 7
... P2 625.0000 P3 672.1627 R5 690.5692 R4 1. For other frequencies, we recommend the VS-751, please contact VI for details. 2. Frequency 1 must be lower than Frequency 2. Not all combinations are available. Ordering Information VS - 550 - – P2 – P4 Product Family VS: VCSO Package 550 3.5 mm Input L: 3.3 V ...