ilx506 Sony Electronics, ilx506 Datasheet

no-image

ilx506

Manufacturer Part Number
ilx506
Description
5000-pixel Ccd Linear Image Sensor B/w
Manufacturer
Sony Electronics
Datasheet
For the availability of this product, please contact the sales office.
Description
developed for high resolution facsimiles and copiers.
This sensor reads A3-size documents at a density of
400 DPI (Dot Per Inch). A built-in timing generator
and clock-drivers ensure direct drive at 5V logic for
easy use. In addition, reset pulse can be switched
between internal generation and external input.
Features
• Number of effective pixels: 5000 pixels
• Pixel size: 7µm
• Built-in timing generator and clock-drivers
• Ultra low lag/ultra high sensitivity/low dark output
• Single output method
• Maximum clock frequency: 12.5MHz
Absolute Maximum Ratings
• Supply voltage
• Operating temperature
• Storage temperature
Pin Configuration (Top View)
The ILX506 is a reduction type CCD linear sensor
Sony reserves the right to change products and specifications without prior notice. This information does not convey any license by
any implication or otherwise under any patents or other right. Application circuits shown, if any, are typical examples illustrating the
operation of the devices. Sony cannot assume responsibility for any problems arising out of the use of these circuits.
5000-pixel CCD Linear Image Sensor (B/W)
RSSW
ROG
V
GND
V
GND
V
V
GND
V
OUT
DD1
DD2
DD2
GG
T1
10
11
1
2
3
4
5
6
7
8
9
7µm (7µm pitch)
5000
1
V
V
DD1
DD2
22
21
20
19
18
17
16
15
14
13
12 T2
–10 to +60
–30 to +80
V
RS/SH
V
V
GND
V
GND
T4
T3
CLK
DD1
DD1
DD1
DD2
11
6
°C
°C
V
V
– 1 –
22 pin DIP (Ceramic)
ILX506
E92239B78-PS

Related parts for ilx506

ilx506 Summary of contents

Page 1

... CCD Linear Image Sensor (B/W) For the availability of this product, please contact the sales office. Description The ILX506 is a reduction type CCD linear sensor developed for high resolution facsimiles and copiers. This sensor reads A3-size documents at a density of 400 DPI (Dot Per Inch). A built-in timing generator and clock-drivers ensure direct drive at 5V logic for easy use ...

Page 2

... ILX506 ...

Page 3

... V 9V power supply DD1 1 20 RS/SH Clock pulse or with S/H; without S/H switch power supply DD1 22 CLK Clock pulse 1 Output mode is changeable as follows. 20pin GND 9pin Internal RS GND without S/H — V DD1 Description V RS DD1 Internal RS — with S/H External RS — without S/H – 3 – ILX506 ...

Page 4

... Input capacity of RS/SH pin C RS/SH Frequency of CLK f CLK Frequency Max. Unit 9.5 V 5.25 V (9V) and then V DD1 DD2 (5V) and then V (9V). DD2 DD1 Min. Typ. Max. — 10 — CLK — 10 — ROG — 10 — — 1 12.5 — 1 12.5 – 4 – ILX506 (5V). Unit MHz MHz ...

Page 5

... I VDD2 98 TTE 92 600 Z — — 3 500 5000 , the minimum output to V and the average output to V MIN – 5 – ILX506 Max. Unit Remarks 13.9 V/(lx · s) Note 2 — V/(lx · s) Note Note 4 — V Note 5 — lx · s Note 6 10.0 mV Note 7 ...

Page 6

... Optical signal accumulated time int stands at 10ms. 10 500mV (Typ.) OUT 11) Vos is defined as indicated below. Vout V OS GND 12) Dynamic range is defined as follows. V SAT DRK When optical accumulated time is shorter, the dynamic range gets wider because dark voltage is in proportion to optical accumulated time. – 6 – ILX506 ...

Page 7

... ILX506 ...

Page 8

... ILX506 ...

Page 9

... Clock Pulse Waveform Conditions CLK, ROG pulse related ROG CLK Internal RS mode CLK Vout External RS mode CLK t10 t11 t13 t12 – 9 – ILX506 t10 t10 ...

Page 10

... 4.5 5.0 CLK ROG t10 — t11 — t12 — t13 — – 10 – ILX506 Max. Unit — ns — ns — — — — 5.5 V — 0 — ...

Page 11

... Ta = 25°C) DD1 DD2 Spectral sensitivity characteristics (Standard characteristics) 500 600 700 800 Wavelength [nm] Spatial frequency [cycles/mm] 0 14.3 28.6 42.9 57.1 1.0 0.8 0.6 0.4 0 0.2 0.4 0.6 0.8 Normalized spatial frequency Integration time output voltage characteristics 1 0.5 0 – 11 – ILX506 900 1000 71.4 1.0 (Standard characteristics int – Integration time [ms] ...

Page 12

... CLK – CLK clock frequency [MHz] Offset level vs. V (Standard characteristics 0. 9.5 (Standard characteristics) Vos –0.8mV/° – Ambient temperature [°C] – 12 – ILX506 DD2 12.5 characteristics DD2 Ta = 25°C Vos –0.14 V DD2 4.75 5 5.25 V [V] DD2 ...

Page 13

... Exposure to high temperatures or humidity will affect the characteristics. Accordingly avoid storage or usage in such conditions. 6) CCD image sensors are precise optical equipment that should not be subject to mechanical shocks. (9V) and then V (5V). DD1 DD2 (9V). DD1 – 13 – ILX506 ...

Page 14

... ILX506 ...

Related keywords