TD4 WELWYN [Welwyn Components Limited], TD4 Datasheet

no-image

TD4

Manufacturer Part Number
TD4
Description
Nickel Film Temperature Sensor
Manufacturer
WELWYN [Welwyn Components Limited]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TD4003
Manufacturer:
ST/MOTO
Quantity:
20 000
Part Number:
TD400N02KOF
Manufacturer:
EUPEC
Quantity:
228
Part Number:
TD400N04KOF
Manufacturer:
EUPEC
Quantity:
726
Part Number:
TD400N06KOF
Manufacturer:
EUPEC
Quantity:
334
Part Number:
TD400N08KOF
Quantity:
292
Part Number:
TD400N12KOF
Manufacturer:
EUPEC
Quantity:
387
Part Number:
TD4054WEA
Manufacturer:
TOSHIDA
Quantity:
20 000
Part Number:
TD425N16KOF
Manufacturer:
EUPEC
Quantity:
20 000
188
Note: Product can be calibrated at the factory, at extra cost
Resistance v temperature for 100Ω sensor
Nickel Film
Temperature Sensor
TD4
Electrical Data
Resistance vs Temperature
General Note
Welwyn Components reserves the right to make changes in product specification without notice or liability.
All information is subject to Welwyn’s own data and is considered accurate at time of going to print.
© Welwyn Components Limited
Telephone: +44 (0) 1670 822181 · Facsimile: +44 (0) 1670 829465 · Email: info@welwyn-tt.com · Website: www.welwyn-tt.com
TD4
Temperature range
Resistance Range
Alpha
Standard value
Tolerance
Interchangeability
Self Heating (in air)
Recommended measuring current
Time constant (time to reach 50% of 10°C, in stirred water)
Insulation resistance
Good long term stability
Rugged construction
Extremely economic solution
Resistance
ohms
102.5
107.6
112.8
66.6
70.6
74.8
79.1
83.5
88.0
92.7
97.5
100
Temperature
R
Tolerance Codes
R
25
-50
-40
-30
-20
-10
10
20
25
30
40
50
°C
25
0
· Bedlington, Northumberland NE22 7AA, UK
= 1000 ohms
= 100 ohms
@25°C
@25°C
@100
Resistance
ohms
118.1
123.6
129.2
135.0
140.9
146.9
153.0
159.3
165.7
172.2
ppm/°C
mW/°C
ohms
ohms
ohms
±°C
±°C
secs
mA
°C
Temperature
100
110
120
130
140
150
°C
60
70
80
90
Definitions
1.0
1.0
2.6
D
R
a
R
R
t
Constants:
A
B
Ro
0
100
-55 to 155
20R to 1K
Actual
Welwyn Components
=
=
=
=
=
6000
5850
:
:
:
0.12
>1G
100
2.0
2.0
3.8
0.4
F
1
R
10000 (R
Resistance at 0°C
Resistance at 100°C
Temperature
0.005247
0.00000753
88.0
0
(1+At+Bt
R
4.0
4.0
6.1
0
G
(ppm/°C)
0
- R
2
)
100
)
TT electronics plc
Issue D · 08.03
A subsidiary of

Related parts for TD4

TD4 Summary of contents

Page 1

... Nickel Film Temperature Sensor TD4 • Good long term stability • Rugged construction • Extremely economic solution Electrical Data TD4 Temperature range Resistance Range Alpha R = 100 ohms 1000 ohms 25 Standard value Tolerance Tolerance Codes Interchangeability Self Heating (in air) Recommended measuring current Time constant (time to reach 50% of 10° ...

Page 2

... Bend nom centre Radius 0.6 10.2 0.6 0.24 Marking TD4: Type reference, resistance and tolerance code. Packaging The standard packaging is in boxes. Taped sensors (on reel or in ammo pack) can also be supplied by special request. Standard Quantities Per Package Type Small box Large box Reel Ammo pack ...