DSD-40PC-1-GS-C MURATA-PS [Murata Power Solutions Inc.], DSD-40PC-1-GS-C Datasheet

no-image

DSD-40PC-1-GS-C

Manufacturer Part Number
DSD-40PC-1-GS-C
Description
Manufacturer
MURATA-PS [Murata Power Solutions Inc.]
Datasheet
FEATURES
Precision, autozeroing, factory-calibrated A/D converter
Scientific-grade accuracy, ±2 counts
Miniature size:
Large (0.52"/13.2mm) LED display
Choice of red, green or yellow colors
High-intensity or low-power red LED's optional
Single +5V supply (175mW for low-power models)
Epoxy-encapsulated, 12-pin DIP with built-in color filter
and bezel
3 differential input voltage ranges
DISPLAY HOLD and TEST functions
Optional BCD data outputs for CPU interface
0 to +50°C temperature range
www.murata-ps.com/rohs
DISPLAY TEST
For full details go to
+5V SUPPLY
5V RETURN
2.17" x 0.92" x 0.56"
55mm x 23mm x 14mm
 
DP 3
DP 2
DP 1
1
2
3
4
5
6
CONVERTER
DC/DC
0 Vdc
www.murata-ps.com
+5V
component-like, plug-in meters that provide scientific-grade accuracy (typically ±2 counts
or ±0.005% of full scale) and outstanding reliability at a very affordable price.
contains a precision reference circuit; a high-resolution, autozeroing, factory-calibrated
A/D converter; and a large (0.52”/13.2mm), easy-to-read, LED display. LED’s are available
in red, yellow and green colors. Red LED’s are also offered in high-intensity or low-power
versions.
long-term operation. Differential input voltage ranges include ±2V, ±20V and ±200V. Input
impedance is a minimum 800kΩ. Non-inverting inputs are overvoltage protected to ±250V,
and CMRR is typically 86dB (dc to 60Hz).
The moisture and vibration-proof package is extremely rugged and well suited for harsh
environments and extended temperatures. Devices are fully specified for
0 to +50°C operation.
power models, whose display is just as bright as standard models, typically consume
175mW. DISPLAY TEST and HOLD functions are standard on each meter, and a complete
set of BCD outputs are optional for sending data to CPU's or remote displays.
DATA
CONVERTER
–5V
DMS-40PC Series, 4½ Digit, LED Display, Miniature DPM’s are fully self-contained,
Within its miniature (2.17” x 0.92” x 0.56”), epoxy-encapsulated package, each meter
The versatile design of the DMS-40PC Series assures trouble-free installation and
The DMS-40PC's epoxy-encapsulated package has an integral bezel and color filter.
All models operate from a single +5V supply and typically consume 500mW. Low-
A/D
1
V–
V+
R2 is not used on ±2V (-1) models.
R2 = 101k on ±20V (-2) models and 9.2k on ±200V (-3) models.
4½ Digit, LED Display Digital Panel Voltmeters
Technical enquiries email: sales@murata-ps.com, tel:
0.01μF
+5V
REF.
2.5V
DMS-40PC Series
R2
1
909k
R1
MPM_DMS-40PC.C03 Page 1 of 6
12
11
10
9
8
7
ANALOG
COMMON
REFERENCE IN/OUT
(–) INPUT LO
(+) INPUT HI
DP4
DISPLAY HOLD
+1 508 339 3000

Related parts for DSD-40PC-1-GS-C

DSD-40PC-1-GS-C Summary of contents

Page 1

FEATURES Precision, autozeroing, factory-calibrated A/D converter Scientific-grade accuracy, ±2 counts Miniature size: 2.17" x 0.92" x 0.56" 55mm x 23mm x 14mm Large (0.52"/13.2mm) LED display Choice of red, green or yellow colors High-intensity or low-power red LED's optional Single ...

Page 2

Performance/Functional Specifications Typical +25°C and supply voltage = +5V using the single-ended input A circuit, unless otherwise noted. Analog Inputs Min. Full Scale Input Range: DMS-40PC-1 – DMS-40PC-2 – DMS-40PC-3 – Input Impedence: – DMS-40PC-1 100 DMS-40PC-2, ...

Page 3

DISPLAY HOLD (Pin 9): For normal operation, this pin should be left open. To hold the meter’s last reading and display it continuously, tie pin 9 to ground (pin 3, 5V RETURN). 5. Decimal Point Placement: The location of ...

Page 4

APPLICATIONS 2. Differential Input Configurations: Differential inputs can also be measured with DMS-40PC meters as shown in the circuit of Figure 3. Differential inputs must also originate from power supplies that have a common ground with the meter’s 5V RETURN ...

Page 5

APPLICATIONS 5. Engineering Scaling and Input Attenuation: In many applications, the input signal must be scaled, or divided down, before being applied to the DMS-40PC. In some situations, the input signal exceeds the full-scale range of the meter, and in ...

Page 6

MECHANICAL DIMENSIONS: Inches (mm) TOLERANCES DEC ±0.02 (±0.51 DEC ±0.010 (±0.254) LEAD DIMENSIONS: 0.025 (0.635) x 0.025 (0.635) NOMINAL RECOMMENDED PC BOARD FINISHED HOLE DIAMETER: 0.042 ±0.003 (1.067 ±0.076) CALIBRATION POTENTIOMETER HOLE LOCATION PIN 1 (USE ...