im41gr Tyco Electronics, im41gr Datasheet

no-image

im41gr

Manufacturer Part Number
im41gr
Description
Im Relay
Manufacturer
Tyco Electronics
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IM41GR
Manufacturer:
AXICOM
Quantity:
20 000
Part Number:
IM41GR
Manufacturer:
TYCO
Quantity:
20 000
The Best Relaytion
IM Relay
108-98001
Rev. D
EC-JM00-0009-03
ECOC: JM10
1. Apr. 04

Related parts for im41gr

im41gr Summary of contents

Page 1

The Best Relaytion IM Relay 108-98001 Rev. D EC-JM00-0009-03 ECOC: JM10 1. Apr. 04 ...

Page 2

... IM relay product conformance according to Compliance is evidenced by written declaration from all raw 1 material suppliers. Tyco Electronics AXICOM only has responsibility for the proper processing of these materials. Confirmation is valid for date codes ≥ 0438 Page 2 (11) 108-98001 Rev 508 File No. E111441 ...

Page 3

IM Relay Dimensions IM THT IM THT Standard Narrow mm inch mm 10 ±0.08 0.393 ±0.003 10 ±0.08 0.393 ±0.003 10 ±0. ±0.08 0.236 ±0.003 5.7 ±0.3 0.224 ±0.012 6 ±0.08 H 5.65 -0.2 0.222 -0.008 5.85 ...

Page 4

IM Relay Coil Data (values at 23°C) Nominal Operate/set voltage range voltage Unom Minimum Maximum voltage U voltage U min max Vdc Vdc Vdc THT Standard non-latching 1 coil 1.5 1.13 3.6 3 2.25 7.2 4.5 3.38 10.8 5 3.75 ...

Page 5

... IM42JR 5-1462037-7 250 IM43JR 6-1462037-0 380 IM44JR 6-1462037-3 810 IM45JR 6-1462037-5 1440 IM46JR 6-1462037-8 2880 IM47JR 7-1462037-1 23 IM40GR 5-1462037-1 90 IM41GR 5-1462037-4 203 IM42GR 3-1462037-1 250 IM43GR 5-1462037-9 380 IM44GR 6-1462037-2 810 IM45GR 6-1462037-4 1440 IM46GR 6-1462037-7 2880 IM47GR 7-1462037-0 250 IM43CGR ...

Page 6

IM Relay Coil operating range 3.4 3.2 3 2.8 2.6 2.4 2 1.6 max. 1.4 1.2 U nominal coil voltage 1 nom. 0.8 0.6 0.4 0.2 0 -60 -50 -40 -30 -20 -10 0 ...

Page 7

IM Relay Contact Data Number of contacts and type Contact assembly Contact material Limiting continuous current at max. ambient temperature Maximum switching current Maximum swichting voltage Maximum switching capacity Thermoelectric potential Minimum switching voltage Initial contact resistance / measuring condition: ...

Page 8

IM Relay General data Operate time at U typ. / max. nom Reset time (latching typ. / max. nom Release time without diode in parallel (non-latching), typ. / max. Release time with diode in parallel (non-latching), typ. ...

Page 9

IM Relay Packing Tube for THT version - 50 relays per tube, 1000 relays per box Tape and reel for SMT version - 1’000 relays / reel, 1’000 or 5’000 relays / box Reel dimension Page 9 (11) 108-98001 Rev. ...

Page 10

IM Relay IM Relays 4 generation slim line – low profile polarized 2 c/o telecom relay with th bifurcated contacts, available as non latching or latching relay with 1 coil. Nominal voltage range from 1.5... 24 V, coil power consumption ...

Page 11

... Fax +41 1 782 9080 E-mail: axicom@tycoelectronics.com Tyco Electronics Paulsternstrasse 26 D-13629 Berlin / Germany Phone +49 30 386 38573 Fax +49 30 386 38575 E-mail: axicom@tycoelectronics.com Tyco Electronics EC Trutnov s.r.o. Komenského 821 CZ-541 01 Trutnov / Czech Republic E-mail: axicom@tycoelectronics.com Tyco Electronics Corporation POB 3608, Harrisburg, PA 17105, USA Phone +1 800-522-6752 Page 11 (11) 108-98001 Rev ...