C1300_09 VECTRON [Vectron International, Inc], C1300_09 Datasheet

no-image

C1300_09

Manufacturer Part Number
C1300_09
Description
Typical Applications
Manufacturer
VECTRON [Vectron International, Inc]
Datasheet
Typical Applications
Military Systems
Avionics and Instrumentation
Test Equipment
Medical Equipment
Frequency Range
Standard Frequencies
Frequency Stabilities
Parameter
Operating temperature range
(referenced to +25° C)
Initial accuracy (do not use with
overall tolerance code below)
Parameter
Overall tolerance (includes operating
temperature and initial accuracy)
Additional stability parameters:
vs. Supply voltage change
vs. Load change
vs. Aging / 1st year
vs. Aging / year (following years)
Supply Voltage (Vs)
Parameter
Supply voltage
Current consumption
(+5 VDC)
Supply voltage
Supply voltage
Current consumption
(+3.3 VDC or +2.5 VDC)
Vectron International ·
Vectron International
Headquarters
267 Lowell Road
Hudson, New Hampshire 03051
+1-888-328-7661 tel
+1-888-329-8328 fax
www.vectron.com
1
7
Vectron International LLC.
100 Watts Street
Mount Holly Springs, PA 17065
USA
+1-717-486-3411 tel
+1-717-486-5920 fax
3.135
2.375
-100
-100
-100
-100
-100
-100
-100
4.75
Min
Min
Min
-50
-25
-15
-50
-25
-50
-15
-25
-50
-50
-25
-20
-50
-25
-65
-2
-1
-3
-1
Typ
Typ
Typ
5.0
3.3
2.5
C1300
Features
9X14 J Leaded Surface Mount Package
Reflow Process Compatible
ACMOS, TTL, LVPECL and LVDS
MIL-PRF-55310 Class B Screening (optional)
Military Operating Temperature Range (optional)
1 to 800 MHz (ACMOS and TTL outputs
available up to 125 MHz. LVPECL and LVDS
output frequencies above 220 MHz are achieved
through the use of a PLL multiplier.)
19.44, 32.768, 44.736, 51.84, 77.76, 155.52, 622.08 MHz
3.465
2.625
+100
+100
+100
+100
+100
+100
+100
Max
Max
Max
5.25
+50
+25
+15
+50
+25
+50
+15
+25
+50
+50
+25
+20
+50
+25
+65
+2
+1
+3
+1
15
20
40
12
16
40
75
6
8
Vectron international GmbH & Co. KG
Landstrasse
D-74924 Neckarbischofsheim
Germany
+49-07268-801-0 tel
+49-07268-801-281 fax
Units
Units
Units
VDC
VDC
VDC
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
mA
mA
mA
mA
mA
mA
mA
mA
mA
ACMOS or TTL 1.0 to 23.9 MHZ
ACMOS or TTL 24 to 49.9 MHz
ACMOS or TTL 50 to 125.00 MHz
ACMOS 85.0 to 125.0 MHz
LVPECL or LVDS No load <200 MHz
ACMOS 1.0 to 14.90 MHZ
ACMOS 15.0 to 39.9 MHz
ACMOS 40.0 to 59.9 MHz
ACMOS 60.0 to 84.9 MHz
-55 … +125° C
-55 … +125° C
-55 … +125° C
-55 … +125° C
-40 … +85° C
-40 … +85° C
-40 … +85° C
-40 … +85° C
-40 … +85° C
-40 … +85° C
0 … +70° C
0 … +70° C
0 … +70° C
0 … +70° C
0 … +70° C
0 … +70° C
0 … +70° C
0 … +70° C
Load ± 5%
Condition
Condition
Condition
V
@ 25° C
@ 25° C
@ 25° C
@ 25° C
S
± 5%
Vectron Asia Pacific Sales Office
Unit 3119 31st Floor, Jin Mao Tower, 88
Century Boulevard, Shanghai,
P.R. China 200120
+86 21 28909740 tel.
+86 21 28909240 fax
v.2009-09-15-05 · page 1 of 4 SEM
Ordering Code
Ordering Code
Ordering Code
TM104
TM605
TC104
TC505
TC255
TC205
SV050
SV033
SV025
TF104
TF505
TF255
M104
M505
C104
C505
C255
C155
F104
F505
F255
T155
T255
T505
T104
PXO
5
5
5

Related parts for C1300_09

C1300_09 Summary of contents

Page 1

Typical Applications Military Systems Avionics and Instrumentation Test Equipment Medical Equipment Frequency Range Standard Frequencies 1 Frequency Stabilities Parameter Operating temperature range (referenced to +25° C) Initial accuracy (do not use with overall tolerance code below) Parameter Overall tolerance (includes ...

Page 2

RF Output Parameter Signal Load Signal Level (Vol) Signal Level (Voh) Rise and fall times for ACMOS (measured 10% to 90%) Duty cycle Signal Load Signal Level (Vol) Signal Level (Voh) Rise and fall times for TTL (measured 0.8V to ...

Page 3

Standard Environmentals Parameter Vibration Shock Acceleration Temperature Cycling Thermal Shock Solderability Leak Test (Fine and Gross) Absolute Maximum Ratings Parameter Supply voltage (Vs) Operable temperature range Storage temperature range Enclosures Type A – ACMOS or TTL Package Codes: Codes Height ...

Page 4

How to Order this Product: Use this worksheet to forward the following information to your factory representative (example follows): Step 1 Stability Initial Accuracy Model Code Code (if required) C1300 C505 T505 Step 2 The factory representative will then ...

Related keywords