MAX7367EUP MAXIM [Maxim Integrated Products], MAX7367EUP Datasheet
MAX7367EUP
Available stocks
Related parts for MAX7367EUP
MAX7367EUP Summary of contents
Page 1
... Bus-Loading Isolation o Support Clock Stretch, Synchronization, and Arbitration o Hot Insertion o 2.3V to 5.5V Supply Voltage Range o 5V-Tolerant Inputs o Interrupt from Extended Buses (MAX7367/MAX7369) o Hardware Reset (MAX7367/MAX7368) PART MAX7367EUP+ MAX7368EUE+ MAX7369EUP+ + Denotes a lead(Pb)-free/RoHS-compliant package. Applications TOP VIEW Pin Configurations continued at end of data sheet. Features 2 C ...
Page 2
I C Switches/Multiplexer ABSOLUTE MAXIMUM RATINGS V to GND ...........................................................-0.3V to +6.0V DD All Other Pins to GND............................................-0.3V to +6.0V Input Currents V ...............................................................................100mA DD GND ..............................................................................100mA All Input Pins.................................................................±20mA Output Current ....................................................................25mA Stresses beyond those listed under ...
Page 3
I ELECRTICAL CHARACTERISTICS (3.3V SUPPLY) (continued 2.3V to 3.6V -40°C to +85°C, unless otherwise noted. Typical values are PARAMETER SYMBOL PASS GATE Switch On-Resistance R ON Switch Output Voltage V PASS ...
Page 4
I C Switches/Multiplexer ELECRTICAL CHARACTERISTICS (5V SUPPLY) (continued 4.5V to 5.5V -40°C to +85°C, unless otherwise noted. Typical values are PARAMETER SYMBOL Input Leakage Current I L Input Capacitance C ...
Page 5
I TIMING CHARACTERISTICS (Figure 1) (continued 2.3V to 5.5V -40°C to +85°C, unless otherwise noted.) (Note PARAMETER SYMBOL Fall Time of Both SDA and SCL Signals Capacitive Load for Each Bus Line ...
Page 6
I C Switches/Multiplexer INT_ INT Figure 2. INT Timing Diagram SCL SDA RESET Figure 3. RESET Timing Diagram 6 _______________________________________________________________________________________ 50 W(REJ)L W(REJ)H 50% t REC;STA 50 50% t RST t WL(RST) ...
Page 7
+5V +25°C, unless otherwise noted PROPAGATION DELAY vs. SUPPLY VOLTAGE 400kHz IN 6 FALLING EDGE RISING EDGE 1 0 2.3 2.7 3.1 3.5 3.9 4.3 ...
Page 8
I C Switches/Multiplexer PIN MAX7367 MAX7368 MAX7369 — 4 — — ...
Page 9
I SC0 SC1 SC2 SC3 SD0 SD1 SD2 SD3 RESET POWER-ON RESET V DD SCL GLITCH FILTER SDA INT[0–3] _______________________________________________________________________________________ _______________________________________________________________________________________ 2 C Switches/Multiplexer MAX7367 Functional Diagram SWITCH CONTROL LOGIC MAX7367 BUS CONTROL INTERRUPT LOGIC A0 ...
Page 10
I C Switches/Multiplexer SC0 SC1 SC2 SC3 SD0 SD1 SD2 SD3 RESET POWER-ON RESET V DD SCL GLITCH FILTER SDA 10 ______________________________________________________________________________________ MAX7368 Functional Diagram SWITCH CONTROL LOGIC MAX7368 BUS CONTROL GND ...
Page 11
I SC0 SC1 SC2 SC3 SD0 SD1 SD2 SD3 POWER- RESET SCL GLITCH FILTER SDA INT[0–3] ______________________________________________________________________________________ 2 C Switches/Multiplexer MAX7369 Functional Diagram SWITCH CONTROL LOGIC MAX7369 BUS CONTROL INTERRUPT LOGIC ...
Page 12
I C Switches/Multiplexer Detailed Description The MAX7367/MAX7368/MAX7369 bidirectional, four- 2 channel I C switches/multiplexer expand the main I bus up to four extended buses. The MAX7369 is a 1:4 multiplexer that connects the main I nel at a ...
Page 13
I CHANNEL SELECTION BITS (READ/WRITE DON'T CARE. Figure 7. MAX7368 Control Register INTERRUPT BITS CHANNEL SELECTION BITS (READ ONLY ...
Page 14
I C Switches/Multiplexer RESET Input (MAX7367/MAX7368) The MAX7367/MAX7368 feature an active-low RESET input. When RESET is driven low for more than 4ns, the MAX7367/MAX7368 reset the internal register and I state machine to their default states, allowing a ...
Page 15
I A master initiates communication with a slave device by issuing a START condition followed by a slave address byte. The slave address byte consists of 7 address bits and a read/write bit (R/W). When idle, the MAX7367/MAX7368/MAX7369 continuously ...
Page 16
I C Switches/Multiplexer Choosing Pullup Resistors requires pullup resistors to provide a logic-high level to data and clock lines. There are tradeoffs between power dissipation and speed, and a compro- mise must be made in ...
Page 17
SDA SCL MASTER * FOR MAX7367/MAX7368. ** FOR MAX7368/MAX7369. () FOR MAX7367/MAX7369. ______________________________________________________________________________________ 2 C Switches/Multiplexer Typical Operating Circuit SDA SD0 SCL SC0 (INT0) (INT) V RESET * MAX7367 SD1 MAX7368 ...
Page 18
I C Switches/Multiplexer For the latest package outline information and land patterns www.maxim-ic.com/packages. PACKAGE TYPE 20 TSSOP 16 TSSOP 18 ______________________________________________________________________________________ Package Information PACKAGE CODE U20-3 U16-1 DOCUMENT NO. 21-0066 21-0066 ...
Page 19
I REVISION REVISION 0 10/06 1 12/06 2 2/09 Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are implied. Maxim reserves the right to change ...