SPECIFICATIONS
Contact
Coil (polarized) (at 20 C
Note: All specifications are based on the condition of 25 C 77°F, 50% R.H. unless
otherwise specified.
TYPICAL APPLICATIONS
Office and industrial electronic devices
• Terminal devices of information process-
ing equipment, such as printer, data re-
corder.
• Office equipment (copier, facsimile)
• Measuring instruments
• NC machines, temperature controllers
and programmable logic controllers.
234
Arrangement
Contact material
Initial contact resistance, max.
(By voltage drop 6 V DC 1A)
Nominal switching capacity
Rating
(resistive)
Expected
life (min.
operations)
Minimum
operating
power
Nominal
operating
power
DSP1a
Max. switching power
Max. switching voltage
Max. switching current
Mechanical (at 180 cpm)
Electrical
Single side stable
2 coil latching
Single side stable
2 coil latching
DSP1
68
F)
5A 30 VDC
2,000 VA
mm
8A 250
150 W
VAC
8 A
1a
Gold flash over silver alloy
inch
MINIATURE POWER RELAY
IN DS RELAY SERIES
250 V AC, 30 V DC
20.2
.795
192 mW
300 mW
192 mW
300 mW
30 m
DSP2a
5 10
1a1b
10
ORDERING INFORMATION
(Note) Standard packing–Carton: 50 pcs.; Case: 500 pcs.
5A 250 VAC
5A 30 VDC
5
1,250 VA
Contact arrangement
7
150 W
5 A
UL/CSA, VDE approved type is standard.
11.0
.433
1: 1a1b
1a: 1a
2a: 2a
10.5
.413
2a
Ex. DSP
FEATURES
• Power types added to DS relay series
• High switching capacity: 1a: 8 A 250 V AC / 1a1b, 2a: 5 A 250 V AC
• High sensitivity: 190 mW pick-up power
• High contact welding resistance
• Latching types available
• High breakdown voltage 3,000 Vrms between contacts and coil
• Sealed types are standard
1,000 Vrms between open contacts Meeting FCC Part 68
Characteristics
Remarks
* Specifications will vary with foreign standards certification ratings.
*
*
*
*
*
*
*
Max. operating speed
Initial insulation resistance*
Initial
breakdown
voltage*
Surge voltage between contacts and coil
Set time*
Reset time*
Operate time*
Release time(without diode)*
(at nominal voltage)
Temperature rise
Soldering temperature
Shock
resistance
Vibration
resistance
Conditions for operation, transport
and storage*
(Not freezing and condensing at low
temperature)
Unit weight
1
2
3
4
5
6
7
1
Measurement at same location as "Initial breakdown voltage" section
Detection current: 10mA
Excluding contact bounce time
Half-wave pulse of sine wave: 11ms; detection time: 10 s
Half-wave pulse of sine wave: 6ms
Detection time: 10 s
R
AMBIENT ENVIRONMENT (Page 61).
efer to 5. Conditions for operation, transport and storage mentioned in
Nil: Single side stable
L2: 2 coil latching
Operating function
2
3
(at nominal voltage)
3
7
(at nominal voltage)
Between open contacts
Between contact sets
Between contacts and coil
Functional*
Destructive*
Functional*
Destructive
3
L
(at nominal voltage)
4
6
5
DSP-
RELAYS
1
DC12V
3
Coil voltage
DC: 3, 5, 6,
9, 12, 24 V
117.6 m/s
205.8 m/s
at double amplitude of 3.5 mm
at double amplitude of 2 mm
Min. 1,000 M
Max. 10 ms (Approx. 5 ms)
Max. 10 ms (Approx. 4 ms)
Max. 10 ms (Approx. 5 ms)
–40 C to +65 C
Max. 5 ms (Approx. 4 ms)
250 C (10 s) 300 C (5 s),
Max. 55 C (1a, 2a types)
Max. 40 C (1a1b type)
2,000 Vrms (1a1b, 2a)
Min. 980 m/s
Min. 196 m/s
30 cps. at rated load
Approx. 4.3 g
Nil: Standard polarity
R: Reverse polarity
Min. 5,000 V
1,000 Vrms
3,000 Vrms
350 C (3 s)
R
2
2
{12 G}, 10 to 55 Hz
{21 G}, 10 to 55 Hz
Polarity
– 40 F 149 F
at 500 V DC
2
2
{100 G}
.15 oz
{20 G}