LF13-WBJ-11P HIROSE [Hirose Electric], LF13-WBJ-11P Datasheet

no-image

LF13-WBJ-11P

Manufacturer Part Number
LF13-WBJ-11P
Description
Miniature Waterproof Shielded Connectors
Manufacturer
HIROSE [Hirose Electric]
Datasheet
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
■Features
1. Ease of shielded termination and connector
2. Water and dust protected
3. Bayonet lock
4. High current rating capacity
5. RoHS compliant
■Applications
assembly
All components are self-aligning and do not require complex
assembly tooling. The shield of the cable is connected with the
metal housing of the connector using simple shielding clamp,
supplied with the connector.
IP67 protection rating. Complete protection against dust
penetration and against water penetration when mated
assembly is submerged at the depth of 1.8 meter for 48 hours.
Short turn bayonet lock assures secure vibration resistant
mating of the connectors.
All components and materials comply with the requirements of
the EU Directive 2002/95/EC.
Sensors, robots, injection molding machines, NC, factory
automation equipment, surveying instruments, measuring
instruments, medical equipment, surveillance cameras and
base stations.
Number of contacts
NEW
6, 12 and 20
Miniature Waterproof Shielded Connectors
LF Series
11
3
4
Current rating
10A max.
10A max.
5A max.
2A max.
2A max.
Mated dimensions
Short turn bayonet lock
Un-mating:
Shielding Connection - Plug
Mating:
Receptacle
Receptacle
Turn the locking collar counter-clockwise
than pull off the plug.
Insert the plug, and then turn the locking collar clockwise,
as indicated by the coupling direction marking.
8.9 mm max. (3 pos.)
Built-in shield
connection spring
Locking collar
Coupling direction marking
Cable shielding connection clamp
36.4
Coupling direction marking
2008.5
Plug
Cable
Plug
1

Related parts for LF13-WBJ-11P

LF13-WBJ-11P Summary of contents

Page 1

The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on ...

Page 2

The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on ...

Page 3

... LF07WBR-6P 136-1001-7 LF07WBR-6S 136-1002-0 LF10WBR-4P 136-1005-8 LF10WBR-4S 136-1006-0 LF10WBR-12P 136-1007-3 LF10WBR-12S 136-1008-6 LF13WBR-20P 136-1009-9 LF13WBR-20S 136-1010-8 LF13WBR-11P 136-1011-0 LF13WBR-11S 136-1012-3 Note: Recommended hex nut tightening torque: 1 N·m (3,4,6, and 12 pos.), 2 to 2.5 N·m (11, 20 pos.) Contact Number of contacts ØA Female 3 Male 12.3 Female ...

Page 4

... Part number CL No. LF07WBJ-3P 136-2003-8 LF07WBJ-3S 136-2004-0 LF07WBJ-6P 136-2001-2 LF07WBJ-6S 136-2002-5 LF10WBJ-4P 136-2005-3 LF10WBJ-4S 136-2006-6 LF10WBJ-12P 136-2007-9 LF10WBJ-12S 136-2008-1 LF13WBJ-20P 136-2009-4 LF13WBJ-20S 136-2010-3 LF13WBJ-11P 136-2011-6 LF13WBJ-11S 136-2012-9 4 Contact Number of contacts ØA ØB Male 3 Female 10.3 11.5 Male 6 Female Male 4 Female 12.8 13.8 Male 12 Female Male ...

Page 5

... Note 3: Withstanding voltages are test voltage values. Description Manual cable clamp crimp Note: Applicable cable dia. is only 5mm for LF series. Applicable connectors LF07WBP-6S,6P,3S,3P LF07WBJ-6S,6P,3S,3P LF10WBP-4S,4P,12S,12P LF10WBJ-4S,4P,12S,12P LF13WBP-20S,20P,11S,11P LF13WBJ-20S,20P,11S,11P Shell size LF07 LF10 LF13 +0. LF07 ...

Page 6

... Insert the jack into the securely held solder termination fixture as shown. Fixture Part No. Applicable connector LF07BJ-T01 LF07WBJ-6S,6P,3S,3P LF10BJ-T01 LF10WBJ-4S,4P,12S,12P LF13BJ-T01 LF13WBJ-20S,20P,11S,11P 2 Loosen the backshell turning it counterclockwise. Connector Assembly 1 Apply a coating of Loctite 7649 (Manufactured by Henckel Japan, Ltd,) primer to the threaded sections of the backshell and the tightening collar ...

Page 7

The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on ...

Page 8

The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on ...

Page 9

... E Table 5 Shell size E LF07 5mm max. LF10 7mm max. LF13 LF Series●Miniature Waterproof Shielded Connectors Operation Crimping of the Shielding Clamp 1 After completion of the soldering operations carefully remove (holding on the locking collar) the body/insulator assembly from the solder termination fixture. ...

Page 10

... For jack assembly Applicable connector Fixture Part No. LF07BJ-T01 LF07WBJ-6S,6P,3S,3P LF10BJ-T01 LF10WBJ-4S,4P,12S,12P LF13BJ-T01 LF13WBJ-20S,20P,11S,11P 2 Coat the thread section of the body/insulator assembly with Loctite 271 compound (manufactured by Henckel Japan, Ltd.) or equivalent, tightening it with a torque specified in the table 6. Note It is critical that the cable itself will not turn or twist during this operation ...

Page 11

... Do not pull on the cable. Shell size Tightening torque Wrench width 0.8N · m~1N · m LF07 10mm 0.7N · m~1N · m LF10 13mm 1 N · m~1.5 N · m LF13 16mm 12 pos. 20 pos. 11 pos. Soft copper wire Soft copper wire Ø0.16 Ø0.26 7 /Ø0.16 mm dia. 26 /Ø0.26 mm dia. AWG #26 AWG #16 0 ...