TLE5206-2_07 INFINEON [Infineon Technologies AG], TLE5206-2_07 Datasheet - Page 6

no-image

TLE5206-2_07

Manufacturer Part Number
TLE5206-2_07
Description
5-A H-Bridge for DC-Motor Applications
Manufacturer
INFINEON [Infineon Technologies AG]
Datasheet
1.7
Undervoltage lockout (UVLO):
When
All output transistors are switched off if the supply voltage
value
1.8
Various errors like short-circuit to +
result in turn-OFF of the output stages after a delay of 50 µs and setting of the error flag
EF to ground. Changing the inputs resets the error flag.
a. Output Shorted to Ground Detection
b. Output Shorted to +
c. Overload Detection
d. Overtemperature Protection
Data Sheet
If a high side transistor is switched on and its output is shorted to ground, the output
current is internally limited. After a delay of 50 µs all outputs will be switched-OFF and
the error flag is set.
If a low side transistor is switched on and its output is shorted to the supply voltage,
the output current is internally limited. After a delay of 50 µs all outputs will be
switched-OFF and the error flag is set.
An internal circuit detects if the current through the low side transistor exceeds the
trippoint
At a junction temperature higher than 150 °C the thermal shutdown turns-OFF, all four
output stages commonly and the error flag is set with a delay.
V
V
S OFF.
S
Monitoring Functions
Protective Function
reaches the switch on voltage
I
SDL
. In this case all outputs are turned off after 50 µs and the error flag is set.
V
S
Detection
V
S
, ground or across the load are detected. All faults
V
S ON
6
the IC becomes active with a hysteresis.
V
S
drops below the switch off
Rev.1.1, 2007-07-31
TLE 5206-2
Overview