TPS40LB TOTAL-POWER [Total Power International], TPS40LB Datasheet

no-image

TPS40LB

Manufacturer Part Number
TPS40LB
Description
SWITCHING MODE 40W LOW COST BOX TYPE POWER SUPPLY
Manufacturer
TOTAL-POWER [Total Power International]
Datasheet
*Input range-----------90~264 VAC, universal
*Frequency------------47~63Hz
*Inrush current--------30A typical, Cold start
*Efficiency------------65% ~80% typical at full load
*EMI filter------------ FCC Class B conducted, CISPR 22
*Line regulation----- +/- 0.5% typical
*Maximum power----40W convection(Refer next page)
*Hold-up time --------10ms typical at full load and 115 VAC
*Overload protection-Short circuit protection
*Overvoltage
*Ripple/Noise -------- +/- 1% Max. @full load
ELECTRICAL SPECIFICATIONS
INPUT
OUTPUT
protection ------------Main output 20% to 40% above
TPS40LB SWITCHING MODE 40W LOW COST BOX TYPE POWER SUPPLY
(Watts)
Output
Power
65W
40W
25W
10W
0W
Ambient Temperature( ° ° ° ° C)
0
Power Derating Curve
Class B conducted, EN55022 class B
Conducted
10
nominal line
nominal output
(Optional +/-0.5% per inquiry
Convection
Natural
Cooling
20
TOTAL POWER, INT. TEL: 877-646-0900 FAX: 978-453-7395
30
E-mail: sales@total-power.com http://www.total-power.com
40
50
60
70
TOTAL POWER INT.
@25℃,115VAC
20 W
)
-1-
APPLICATIONS
EMI & EMC (IN PROCESS)
*Built-in EMI filter
*LOW COST
*Telecommunications
*Computer peripherals/Lan & Hub
*Test & industrial equipments
*Medical instruments
*Business machines
*FCC part 15, Class B
*CISPR 22 / EN55022, Class B
*VCCI ,Class 2
*CE , EN61000-3-2 (Class A) and –3 ; EN61000-4-2,
*Optional CSA 22.2, LEVEL 3
*TUV EN60950
*Optional UL 2601(EMI Class A)
*Humidity:
*Vibration :
*Storage temperature:
*Temperature coefficient:
*MTBF demonstrated:
KEY FEATURES
*Universal input
*Optional constant current change (for single output)
SAFETY APPROVAL(IN PROCESS)
*UL1950 / c UL
ENVIRONMENTAL
*Operating temperature :
-3 , -4 , -5 , -6 and -11
0 to
degree from 50℃to 70℃
Operating; non-condensing, 5% to 95%
10~55 Hz at 1G 3 minutes period, 30 minutes along
X, Y and Z axis
-40 to 85℃
+/- 0.05% per degree C
>100,000 hours at full load and 25℃ambient
conditions
50℃
ambient; derate each output at 2.5% per

Related parts for TPS40LB

TPS40LB Summary of contents

Page 1

... TPS40LB SWITCHING MODE 40W LOW COST BOX TYPE POWER SUPPLY ELECTRICAL SPECIFICATIONS INPUT *Input range-----------90~264 VAC, universal *Frequency------------47~63Hz *Inrush current--------30A typical, Cold start *Efficiency------------65% ~80% typical at full load *EMI filter------------ FCC Class B conducted, CISPR 22 Class B conducted, EN55022 class B Conducted *Line regulation----- +/- 0 ...

Page 2

... TOTAL POWER TPS40LB SWITCHING MODE 40W LOW COST BOX TYPE OUTPUT ADJUSTMENT MAXIMUM OUTPUT MODEL VOLTAGE RANGE SINGLE OUTPUT MODEL SELECTION CHART ±10% Typical TPS40LB-10 +5V TPS40LB-11 + 12V ±10% Typical TPS40LB-12 +15V ±10% Typical ±10% Typical TPS40LB-13 +24V TPS40LB-14 +48V ±10% Typical +3.3V ± ...