MPU150 POWER-ONE [Power-One], MPU150 Datasheet

no-image

MPU150

Manufacturer Part Number
MPU150
Description
Power Factor Correction (PFC) Meets EN61000-3-2
Manufacturer
POWER-ONE [Power-One]
Datasheet
Rev. 06/99
The innovative MPU150 incorporates Power Factor Correction (PFC)
with a low profile package designed to meet 1U height constraints.
The MPU150-4530 and MPU150-4350 provide high current +3.3V
and +5V on a single platform to support mixed mode, high speed
digital circuitry. Power-One’s unique dual converter architecture
combines high reliability with exceptional regulation.
AC INPUT MODEL SELECTION CHART –
MPU150-3300
MPU150-4000
MPU150-4350
MPU150-4530
DC INPUT MODEL SELECTION CHART –
MDU150-3300
MDU150-4000
MDU150-4530
NOTES: 1) Output currents ratings are expressed with 300 LFM forced air.
FEATURES
• Power Factor Correction (PFC) Meets EN61000-3-2
• Low Profile Height Fits 1U Constraints
• Dual Main Outputs Provide 3.3V and 5V for Mixed Mode Applications
• Single Wire Current Sense on Outputs V1 and V2
• Remote Sense on Outputs V1 and V2
• Overtemperature, Overload, and Overvoltage Protection
• Available with Metric or SAE Mountings
• Greater than 340,000 Hours MTBF
• MDU150 Models have 48VDC Input
MODEL
MODEL
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
3) Total current between V1 and V2 is 30A, maximum rating.
4) Total current between V3 and V4 is 5A, maximum rating.
Advanced Product Release
VOLTAGE
VOLTAGE
OUTPUT
OUTPUT
+3.3V
+3.3V
+3.3V
+3.3V
+3.3V
+12V
+12V
+12V
+12V
+5V
+5V
12V
+5V
12V
12V
+5V
12V
12V
+5V
+5V
12V
+5V
12V
12V
5V
5V
3.15V to 3.80V
10.8V to 13.2V
10.8V to 13.2V
10.8V to 13.2V
3.15V to 3.80V
10.8V to 13.2V
10.8V to 13.2V
3.15V to 3.60V
10.8V to 13.2V
10.8V to 13.2V
3.15V to 3.80V
10.8V to 13.2V
10.8V to 13.2V
10.8V to 13.2V
3.15V to 3.60V
10.8V to 13.2V
10.8V to 13.2V
®
5.0V to 5.5V
5.0V to 5.5V
5.0V to 5.5V
5.0V to 5.5V
5.0V to 5.5V
5.0V to 5.5V
5.0V to 5.5V
5.0V to 5.5V
5.0V to 5.5V
ADJUSTMENT
ADJUSTMENT
RANGE
RANGE
ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS
150W WITH 300 LFM FORCED AIR COOLING
150W WITH 300 LFM FORCED AIR COOLING
ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS
MPU/MDU150 SERIES
CURRENT (NOTE 1)
CURRENT (NOTE 1)
30A (Note 3)
30A (Note 3)
15A (Note 3)
30A (Note 3)
15A (Note 3)
30A (Note 3)
30A (Note 3)
15A (Note 3)
3A (Note 4)
3A (Note 4)
3A (Note 4)
3A (Note 4)
3A (Note 4)
3A (Note 4)
OUTPUT
OUTPUT
35A
20A
35A
20A
2A
8A
3A
2A
2A
8A
3A
2A
1
All models feature remote sense on outputs V1 and V2 to provide
independent compensation of output cable losses. Other standard
features include independent current sharing on V1 and V2, thermal
shutdown, and remote inhibit. Airflow of 300 linear feet per minute
(LFM) is required to deliver the full power density of 3.0 watts per
cubic inch.
The MDU150 series provides the same benefits as the MPU150 series,
with nominal 48 volt DC input.
REGULATION
REGULATION
0.6%
0.4%
0.4%
0.4%
0.4%
0.4%
0.4%
0.6%
0.4%
0.4%
0.4%
0.4%
0.6%
0.4%
0.4%
0.6%
0.4%
0.4%
0.4%
0.4%
0.4%
0.4%
0.4%
0.6%
0.4%
0.4%
LINE
LINE
REGULATION
REGULATION
1.5%
1.5%
1.5%
1.5%
1.5%
LOAD
LOAD
3%
3%
1%
1%
1%
1%
1%
7%
7%
1%
7%
7%
3%
3%
1%
1%
1%
1%
1%
7%
7%
%Pk-Pk (NOTE 2)
%Pk-Pk (NOTE 2)
RIPPLE & NOISE
RIPPLE & NOISE
1.5%
1.5%
1.5%
1.5%
1.5%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
11.76V to 12.24V
11.94V to 12.06V
11.94V to 12.06V
11.94V to 12.06V
11.94V to 12.06V
11.94V to 12.06V
11.94V to 12.06V
11.76V to 12.24V
11.94V to 12.06V
11.94V to 12.06V
11.94V to 12.06V
11.94V to 12.06V
3.28V to 3.32V
4.98V to 5.02V
4.98V to 5.02V
4.98V to 5.02V
3.28V to 3.32V
5.00V to 5.04V
4.98V to 5.02V
3.28V to 3.32V
3.28V to 3.32V
4.98V to 5.02V
4.98V to 5.02V
4.98V to 5.02V
4.98V to 5.02V
3.28V to 3.32V
INITIAL SETTING
INITIAL SETTING
ACCURACY
ACCURACY

Related parts for MPU150

MPU150 Summary of contents

Page 1

... Airflow of 300 linear feet per minute (LFM) is required to deliver the full power density of 3.0 watts per cubic inch. The MDU150 series provides the same benefits as the MPU150 series, with nominal 48 volt DC input. 150W WITH 300 LFM FORCED AIR COOLING ...

Page 2

... MPU150 INPUT SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION Input Voltage - AC Continuous input range. Input Frequency AC input. Hold-up Time After last AC line peak at 150 watts. Input Current 85 VAC at full rated load. Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Internally limited by thermistor. Vin = 230 VAC, one cycle, 25°C. ...

Page 3

... Add “M” suffix to the model number to order chassis with M4 x 0.7 mounting inserts. MPU/MDU150 SERIES 3.3V output, V1 3.3V output output, V1, V2 12V output, V2 (Note 1) 3.3V output, V1 MPU150 MDU150 Line to Line Line to Ground MPU150 at 264 VAC MDU150 at 72 VDC At 100% load At 50% load 3 MIN NOM MAX UNITS 4.1 4.65 3.8 4 ...

Page 4

OVERALL SIZE: 8.00" x 4.20" x 1.50" (203.2mm x 106.7mm x 38.1mm) WEIGHT: 2.0 LBS (0.89 kg) TRIPLE OUTPUT INPUT - or N 0.30" 7.400" (188.0mm) (7.6mm) 8.00" (203.2mm) 0.75" 6.500" (165.1mm) (19.1mm) SUGGESTED ...