EP910LI-35

Manufacturer Part NumberEP910LI-35
ManufacturerAltera Corporation
EP910LI-35 datasheet
 


Specifications of EP910LI-35

Date_code07+Packing_infoPLCC
1
2
3
4
5
6
7
8
9
10
11
Page 11
12
Page 12
13
Page 13
14
Page 14
15
Page 15
16
Page 16
17
Page 17
18
Page 18
19
Page 19
20
Page 20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
Page 16/42

Download datasheet (729Kb)Embed
PrevNext
Classic EPLD Family Data Sheet
Notes to tables:
(1)
See the
Operating Requirements for Altera Devices Data Sheet
(2)
Numbers in parentheses are for industrial-temperature-range devices.
(3)
The minimum DC input is –0.3 V. During transitions, the inputs may undershoot to –2.0 V (EP610) or
–0.5 V (EP610I) or overshoot to 7.0 V (EP610) or V
less than 20 ns.
(4)
For EP610 devices, maximum V
monotonic rise.
(5)
For EP610-15 and EP610-20 devices: t
For EP610-15 and EP610-20 clocks: t
(6)
These values are specified in
(7)
The I
parameter refers to high-level TTL or CMOS output current; the I
OH
output current.
(8)
This parameter does not apply to EP610I devices.
(9)
The device capacitance is measured at 25 C and is sample-tested only.
(10) Typical values are for T
= 25° C and V
A
(11) When the Turbo Bit option is not set (non-Turbo mode), EP610 devices enter standby mode if no logic transitions
occur for 100 ns after the last transition. When the Turbo Bit option is not set, EP610I devices enter standby mode if
no logic transitions occur for 75 ns after the last transition.
(12) Measured with a device programmed as a 16-bit counter.
760
in this data book.
+ 0.5 V (EP610I) for input currents less than 100 mA and periods
CC
rise time is 50 ms. For EP610I devices, maximum V
CC
and t
= 40 ns.
R
F
and t
= 20 ns.
R
F
Table 3 on page
758.
= 5 V.
CC
rise time is unlimited with
CC
parameter refers to low-level TTL
OL
Altera Corporation