2.16.1 Reset sequence
To activate the « emergency » reset sequence, the ~RST signal has to be set to
low for 500µs minimum. As soon as the reset is complete, the AT interface
answers « OK » to the application
EXTERNAL RST
STATE OF THE MODULE
2.17
External Interrupt (~INTR)
The WISMO Quik Q24x6 Series provides an external interrupt input (not
managed in the standard AT commands firmware). This input is very sensitive
and an interrupt is activated on high to low edge. If this signal is not used it
can be left open. If used this input has to be driven by an open collector or an
open drain.
This input is used for instance to power OFF automatically the module.
Signal
Pin number
~INTR
16
Parameter
V
IL
V
IH
4
For this, the application has to send AT↵. If the application manages hardware flow control, the
AT command can be sent during the initialisation phase. Another solution is to use the +WIND
command to get an unsollicited status from the module.
confidential ©
This document is the sole and exclusive property of WAVECOM. Not to be distributed or divulged
without prior written agreement.
Ce document est la propriété exclusive de WAVECOM. Il ne peut être communiqué ou divulgué à
des tiers sans son autorisation préalable.
WM_PRJ_Q2400_PTS_002 - 002
4
.
Min:500µs
Typ:2ms
Module READY
RESET mode
I
=20 to
BB+RF
40mA
SIM and network dependent
Figure 14 : Reset sequence
Pin description
I/O
I/O type
I
CMOS
Electrical characteristics
Min
-0.5V
2.2V
24th January 2003
AT answers “OK”
Module READY
Module ON
I
<120mA
BB+RF
without loc update
Description
External Interrupt
Max
Unit
0.7V
Volt
3.0V
Volt
Page : 44 / 81