ICX285

Manufacturer Part NumberICX285
DescriptionTiming Generator for Progressive Scan CCD Image Sensor
ManufacturerSONY [Sony Corporation]
ICX285 datasheet
 
1
2
3
4
5
6
7
8
9
10
11
Page 11
12
Page 12
13
Page 13
14
Page 14
15
Page 15
16
Page 16
17
Page 17
18
Page 18
19
Page 19
20
Page 20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
Page 19/39

Download datasheet (382Kb)Embed
PrevNext
5. TRIG data
(1) SG stop setting (valid only during TRIG drive)
SG pulse (ternary value output of the V2A and V2B pulses) stopped/not stopped during TRIG drive can be
selected by the D0 setting.
When SG stopped is selected, the corresponding V pulse is not stopped.
D0
Description of operation
0
SG not stopped (TRIG drive)
1
SG stopped (TRIG drive)
(2) SUB stop setting (valid only during TRIG drive)
SUB pulse stopped/not stopped during TRIG drive can be selected by the D1 setting.
D1
Description of operation
0
SUB not stopped (TRIG drive)
1
SUB stopped (TRIG drive)
(3) High-speed sweep setting (valid only during TRIG drive)
High-speed sweep on/off during TRIG drive can be selected by the D2 setting.
(For details, see Chart-4 to Chart-7.)
D2
Description of operation
0
High-speed sweep on (TRIG drive)
1
High-speed sweep off (TRIG drive)
The number of V transfers (stages) for high-speed sweep differs according to the drive mode during
TRIG pulse input.
(For details, see Chart-12 and Chart-13.)
DRAFT mode: 20 (stages/H)
FINE/TRIGOUT mode: 5 (stages/H)
(4) Clamp pulse stop setting (valid only during TRIG drive)
XCPDM, XCPOB and PBLK stopped/not stopped from SG pulse generation until 7H after the falling edge
of the next valid VD during TRIG drive can be selected by the D3 setting.
(For details, see Chart-4 to Chart-7.)
D3
Description of operation
0
Clamp pulses not stopped (TRIG drive)
1
Clamp pulses stopped (TRIG drive)
53 (H) = 1060 (stages)
210 (H) = 1050 (stages)
– 19 –
CXD3607R