ICX285 SONY [Sony Corporation], ICX285 Datasheet - Page 27

no-image

ICX285

Manufacturer Part Number
ICX285
Description
Timing Generator for Progressive Scan CCD Image Sensor
Manufacturer
SONY [Sony Corporation]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ICX285AL
Manufacturer:
ATMEL
Quantity:
1 240
Part Number:
ICX285AL-F
Manufacturer:
OMRON
Quantity:
2 300
Part Number:
ICX285AQ
Manufacturer:
MV
Quantity:
5 000
Chart-4 Vertical Timing Chart
TRIG fuction setting
Drive mode setting
XCPDM
XCPOB
PBLK
TRIG
WEN
SUB
OUT
V2A
V2B
VD
HD
V1
V3
V4
TRIG function disabled
DRAFT
The number of SUB pulses is determined by the serial interface data.
Fixed to 53H (20 stages
High-speed sweep block (Chart-12)
Selectable from 1 to 58 pulses by the SUB setting. (Example: 58 pulses)
SG prohibited area (1 to 57H)
MODE
DRAFT mode
(High-speed sweep on, SG generation position: 58H, SUB setting: 58 pulses)
53H = 1060 stages)
TRIG function enabled
DRAFT
TRIG drive
Selectable in the range of 58 to 2048H by the
SG generation position setting. (Example: 58H)
Readout block (Chart-10)
The VD fall is not accepted until 2H after SG generation.
(Example: When the SG generation position is 58H, VD input is not accepted from 1 to 59H, and is accepted from 60H onward.)
These pulses can be stopped by
the clamp pulse stop setting.
TRIG function disabled
TRIGOUT

Related parts for ICX285