IM40JR MACOM [Tyco Electronics], IM40JR Datasheet

no-image

IM40JR

Manufacturer Part Number
IM40JR
Description
IM Series Signal Relays
Manufacturer
MACOM [Tyco Electronics]
Datasheet
IM Series
Signal Relays

Related parts for IM40JR

IM40JR Summary of contents

Page 1

IM Series Signal Relays ...

Page 2

AXICOM Signal Relays IM Relay UL 508 File No. E 111441 UL 60950 IEC/EN60950 IEC Ref. Cert. No. 3270 All specifications subject to change. Consult Tyco Electronics for latest specifications. Disclaimer While Tyco Electronics and its affiliates referenced herein have ...

Page 3

AXICOM Signal Relays IM Relay IM Relay 1 and 2 pole telecom/signal relay, polarized Through Hole Types (THT), standard version with 5.08 mm, narrow with 3.2 mm between the terminal rows or Surface Mount Type (SMT) Relay Types: non – ...

Page 4

AXICOM Signal Relays IM Relay Selection Guide IM-A IM-B 1 Pole break 1 Pole make 1 Form B 1 Form A SPST NC SPST NO IM-A High Dielectric “C” Relay Code IM All specifications subject to change. Consult Tyco Electronics ...

Page 5

AXICOM Signal Relays IM Relay 2 Pole Changeover / 2 Form C / DPDT Dimensions IM THT Standard mm inch L 10.00 ± 0.08 0.393 ± 0.003 W 6.00 ± 0.08 0.236 ± 0.003 H 5.65 – 0.20 0.222 – ...

Page 6

AXICOM Signal Relays IM Relay 2 Pole Changeover / 2 Form C / DPDT Coil Data (values at 23 °C) Nominal Operate/set voltage range voltage U nom Minimum Maximum voltage U voltage U min Vdc Vdc Standard Version THT Standard ...

Page 7

... IM41NS 1-1462038-9 203 IM42NS 2-1462038-0 250 IM43NS 2-1462038-1 360 IM44NS 2-1462038-2 810 IM45NS 2-1462038-3 1440 IM46NS 2-1462038-4 2880 IM47NS 2-1462038-5 23 IM40JR 5-1462037-2 90 IM41JR 5-1462037-5 203 IM42JR 5-1462037-7 250 IM43JR 6-1462037-0 360 IM44JR 6-1462037-3 810 IM45JR 6-1462037-5 1440 IM46JR 6-1462037-8 2880 IM47JR ...

Page 8

AXICOM Signal Relays IM Relay 2 Pole Changeover / 2 Form C / DPDT Coil Data (values at 23 °C) Nominal Operate/set voltage range voltage U nom Minimum Maximum voltage U voltage U min Vdc Vdc High Sensitive Version SMT ...

Page 9

AXICOM Signal Relays IM Relay 2 Pole Changeover / 2 Form C / DPDT Coil Data (values at 23 °C) Nominal Operate/set voltage range voltage U nom Minimum Maximum voltage U voltage U min Vdc Vdc Ultra High Sensitive Version ...

Page 10

AXICOM Signal Relays IM-A Relay 1 Pole Break / 1 Form B / SPST NC Dimensions IM-A THT Version Standard Version Mounting Hole Layout View onto the component side of ...

Page 11

AXICOM Signal Relays IM-A Relay 1 Pole Break / 1 Form B / SPST NC Coil Data (values at 23 °C) Nominal Operate/set voltage range voltage U nom Minimum Maximum voltage U voltage U min Vdc Vdc IM-A SMT Gull ...

Page 12

AXICOM Signal Relays IM-B Relay 1 Pole Make / 1 Form A / SPST NO Dimensions IM-B THT Version Standard Version Mounting Hole Layout View onto the component side of ...

Page 13

AXICOM Signal Relays IM-B Relay 1 Pole Make / 1 Form A / SPST NO Coil Data (values at 23 °C) Nominal Operate/set voltage range voltage U nom Minimum Maximum voltage U voltage U min Vdc Vdc IM-B SMT Gull ...

Page 14

AXICOM Signal Relays IM-C Relay 1 Pole Changeover / 1 Form C / SPDT Dimensions IM-C THT Version Standard Version Mounting Hole Layout View onto the component side of the ...

Page 15

AXICOM Signal Relays IM-C Relay 1 Pole Changeover / 1 Form C / SPDT Coil Data (values at 23 °C) Nominal Operate/set voltage range voltage U nom Minimum Maximum voltage U voltage U min Vdc Vdc IM-C SMT Gull Wings ...

Page 16

AXICOM Signal Relays IM-D Relay 2 Pole Break / 2 Form B / DPST NC Dimensions IM-D THT Version Standard Version Mounting Hole Layout View onto the component side of ...

Page 17

AXICOM Signal Relays IM-D Relay 2 Pole break / 2 Form B / DPST NC Coil Data (values at 23 °C) Nominal Operate/set voltage range voltage U nom Minimum Maximum voltage U voltage U min Vdc Vdc IM-D SMT Gull ...

Page 18

AXICOM Signal Relays IM-E Relay 2 Pole Make / 2 Form A / DPST NO Dimensions IM-E THT Version Standard Version Mounting Hole Layout View onto the component side of ...

Page 19

AXICOM Signal Relays IM-E Relay 2 Pole Make / 2 Form A / DPST NO Coil Data (values at 23 °C) Nominal Operate/set voltage range voltage U nom Minimum Maximum voltage U voltage U min Vdc Vdc IM-E SMT Gull ...

Page 20

AXICOM Signal Relays IM Relay 2 Pole Changeover / 2 Form C / DPDT Contact Data Number of contacts and type Contact assembly Contact material Limiting continuous current at max. ambient temperature Maximum switching current Maximum swichting voltage Maximum switching ...

Page 21

AXICOM Signal Relays IM Relay Contact Data Number of contacts and type Contact assembly Contact material Limiting continuous current at max. ambient temperature Maximum switching current Maximum swichting voltage Maximum switching capacity Thermoelectric potential Minimum switching voltage Initial contact resistance ...

Page 22

AXICOM Signal Relays IM Relay Insulation IM Versions Insulation resistance at 500 Vdc Dielectric test voltage (1 min) between coil and contacts between adjacent contact sets between open contacts Surge voltage resistance according to Telcordia TR-NWT-001089 (2/10 µs) between coil ...

Page 23

AXICOM Signal Relays IM Relay High Frequency Data Capacitance between coil and contacts between adjacent contact sets between open contacts RF Characteristics Isolation at 100 MHz / 900 MHz Insertion loss at 100 MHz / 900 MHz V.S.W.R. at 100 ...

Page 24

AXICOM Signal Relays IM Relay Coil Operating Range 3.4 3 max. 2.8 2 2.4 max. 2 max. 1.6 1.4 1.2 U ...

Page 25

AXICOM Signal Relays IM Relay Recommended Soldering Conditions Soldering conditions according IEC 60058-2-58 and IPC/JEDEC J-STD-020B sec 240 °C 180 °C 130 °C 100 °C Time (s) Recommended Reflow Soldering Profile Time (s) Resistance to Soldering Heat ...

Page 26

AXICOM Signal Relays IM Relay Packing Reel Dimension All specifications subject to change. Consult Tyco Electronics for latest specifications. 108-98001 Rev. M Dimensions in mm Tube for THT version 50 relays per tube 1,000 relays per box Tape and reel ...

Page 27

AXICOM Signal Relays IM Relay IM Relays 4th generation slim line – low profile polarized 2 c/o telecom signal relay with bifurcated contacts, available as non latching or latching relay with 1 coil. Nominal voltage range from 1.5 ... 24 ...

Page 28

Tyco Electronics AMP GmbH Relay Products Group AMPèrestrasse 12-14 64625 Bensheim Germany AXICOM Signal Relay Contact Switzerland Phone: +41-(0)44-782-9111 E-Mail: axicom@tycoelectronics.com www.tycoelectronics.com http://relays.tycoelectronics.com AXICOM, TE (logo) and Tyco Electronics are trademarks of the Tyco Electronics group of companies and its ...

Related keywords