SST85LD0512-60-RI-LBTE Greenliant, SST85LD0512-60-RI-LBTE Datasheet

no-image

SST85LD0512-60-RI-LBTE

Manufacturer Part Number
SST85LD0512-60-RI-LBTE
Description
Flash 512MB NAND 60ns 3.3V Industrial
Manufacturer
Greenliant
Datasheet

Specifications of SST85LD0512-60-RI-LBTE

Rohs
yes
Memory Type
NAND Flash
Memory Size
512 MB
Access Time
60 ns
Supply Voltage - Max
5 V
Supply Voltage - Min
3.3 V
Maximum Operating Current
85 mA
Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
LBGA-88
Features
• Industry Standard ATA/IDE Bus Interface
• Low Power, 3.3V Power Supply
• 5.0V or 3.3V Host Interface Through V
• Low Current Operation:
• Power Management Unit
• Expanded Data Protection
• 20-byte Unique ID for Enhanced Security
• Integrated Voltage Detector
©2010 Greenliant Systems, Ltd.
– Host Interface: 16-bit access
– Supports up to PIO Mode-6
– Supports up to Multi-word DMA Mode-4
– Supports up to Ultra DMA Mode-4
– Active mode: 85 mA Typical
– Sleep mode: 160 µA Typical
– Immediate disabling of unused circuitry without host
– Zero wake-up latency
– WP#/PD# pin configurable by firmware for
– Factory Pre-programmed 10-byte Unique ID
– User-Programmable 10-byte ID
– Prevents data loss due to unexpected power-down or
intervention
prevention of data overwrites
brownout.
The GLS85LD0512 / GLS85LD1001T / GLS85LD1002U NANDrive™ solid-state drive
(SSD) combines a NAND controller and 512 MBytes / 1 GByte / 2 GBytes of NAND flash in a
multi-chip package. It provides complete ATA/IDE hard disk drive functionality in a small pack-
age for easy, space-saving mounting to a system motherboard. This makes the
GLS85LD0512 / GLS85LD1001T / GLS85LD1002U NANDrive SSD the ideal data storage
solution for mobile and embedded electronic products that require smaller and more reliable
storage.
512 MByte/ 1 GByte / 2 GByte NANDrive
DDQ
GLS85LD0512 / GLS85LD1001T / GLS85LD1002U
www.greenliant.com
Pins
• Endurance
• Data Retention
• Pre-programmed Embedded Firmware
• Robust Built-in ECC
• Multi-tasking Technology Enables Fast
• Fast Sustained Read Performance (Flash-to-Host)
• Industrial Temperature Range
• LBGA package
• All Devices are RoHS Compliant
Sustained Write Performance (Host-to-Flash)
– 100 Million write cycles for NANDrive with advanced
– 10 years
– Executes industry standard ATA/IDE commands
– Implements dynamic wear-leveling algorithms to sub-
– Embedded Flash File System
– Up to 20 MByte/sec
– Up to 30 MByte/sec
– -40°C to +85°C for industrial operation
– 12mm x 24mm
NAND management technology
stantially increase the longevity of flash media
S71382-05-000
Data Sheet
05/10

Related parts for SST85LD0512-60-RI-LBTE

SST85LD0512-60-RI-LBTE Summary of contents

Page 1

... Factory Pre-programmed 10-byte Unique ID – User-Programmable 10-byte ID • Integrated Voltage Detector – Prevents data loss due to unexpected power-down or brownout. ©2010 Greenliant Systems, Ltd. 512 MByte/ 1 GByte / 2 GByte NANDrive GLS85LD0512 / GLS85LD1001T / GLS85LD1002U • Endurance – 100 Million write cycles for NANDrive with advanced NAND management technology • ...

Page 2

... PDAs, handy terminals, personal communicators, robotics, audio recorders, monitoring devices, and set-top boxes. Greenliant NANDrive is a single device, solid state drive designed for embedded ATA/IDE protocol systems and supports standard ATA/IDE protocol with up to PIO Mode-6, Multi-word DMA Mode-4 and Ultra DMA Mode-4 interface. The built in microcontroller and file management firmware com- municates with ATA standard interfaces ...

Page 3

... High performance is achieved through optimized hardware error detection and correction. Serial Communication Interface (SCI) The Serial Communication Interface (SCI) is designed for manufacturing error reporting. Always provide SCI interface access to PCB design to aid in design validation. ©2010 Greenliant Systems, Ltd. 3 Data Sheet S71382-05-000 ...

Page 4

... Read-only or Hidden. Functional Blocks Embedded Flash File System SRAM Buffer HOST ATA/IDE BUS Figure 1: NANDrive Block Diagram ©2010 Greenliant Systems, Ltd. 512 MByte / 1 GByte / 2 GByte NANDrive GLS85LD0512 / GLS85LD1001T / GLS85LD1002U NAND Controller MCU ECC Internal DMA PMU SCI ...

Page 5

... SCID 6 DNU 5 DNU 4 DNU RESET# 3 DNU 2 DNU VREG 1 DNU DNU Figure 2: Pin Assignments for 91-Ball LBGA ©2010 Greenliant Systems, Ltd. TOP VIEW (balls facing down) V D11 D14 IOWR# V PDIAG# CSEL D10 D13 D15 IOCS16# A2 CS3FX# OUT SCICLK D8 V D12 ...

Page 6

... DMACK# K2 DMARQ J3 CS1FX# L3 CS3FX# L8 CSEL L9 IORD# H2 ©2010 Greenliant Systems, Ltd. 512 MByte / 1 GByte / 2 GByte NANDrive GLS85LD0512 / GLS85LD1001T / GLS85LD1002U I/O Type Name and Functions I I1Z A[2:0] are used to select one of eight registers in the Task File. I/O I1Z/O2 D[15:0] Data bus I I2U DMA Acknowledge - input from host ...

Page 7

... E2, M9 PWR DDQ POR REG ©2010 Greenliant Systems, Ltd. I/O Type Name and Functions IOWR#: This is an I/O Write Strobe generated by the host. When Ultra DMA mode is not active, this signal is used to clock I/O data into the device. I I2Z STOP: When Ultra DMA mode protocol is active, the assertion of this ...

Page 8

... F5, G5, L4, L6, L7, M3, M4,M5, M6,M7, M8, N2, N3, N4, N5, N6, N7, N8, N9, R9, R10,T9, T10,A1, A2, A9, A10,B1, B9,B10, R1, R2, T1 Analog input for supply voltage detection ©2010 Greenliant Systems, Ltd. 512 MByte / 1 GByte / 2 GByte NANDrive GLS85LD0512 / GLS85LD1001T / GLS85LD1002U I/O Type Name and Functions Do not use. 8 T1.4 1382 S71382-05-000 05/10 ...

Page 9

... GLS85LD1002U-60-RI-LBTE Table 3: Supported ATA Modes Products GLS85LD0512-60-RI-LBTE GLS85LD1001T-60-RI-LBTE GLS85LD1002U-60-RI-LBTE Table 4: Advanced NAND Management Technology Write Cycles Product GLS85LD0512-60-RI-LBTE GLS85LD1001T-60-RI-LBTE 100M GLS85LD1002U-60-RI-LBTE 100M ©2010 Greenliant Systems, Ltd. Cylinders Heads 993 16 1986 16 3969 16 Write Performance MByte/sec ...

Page 10

... ATA/IDE Interface The ATA interface can be used for NANDrive manufacturing support. Greenliant provides an example of a DOS-based solution (an executable routine) for manufacturing debug and rework. ©2010 Greenliant Systems, Ltd. ...

Page 11

... Protection zones - Up to four independent protection zones can be enabled as either Read-only or Hidden (Read/Write protected). If the zones are not enabled, the data is unprotected (default con- figuration). Password Protection - Requires a customer-unique password to access information within the pro- tected zones. ©2010 Greenliant Systems, Ltd. , SCID , and SCICLK. Always provide SCI interface OUT IN ...

Page 12

... Data Sheet Power-on and Brown-out Reset Characteristics Please contact Greenliant to obtain NANDrive reference design schematics including the POR# circuit for industrial NANDrive offerings. V /POR# DD Figure 1: Power-on and Brown-out Reset Timing Table 1: Power-on and Brown-out Reset Timing Item 1 V /POR# Rise Time ...

Page 13

... Format-Track Identify-Drive Idle Idle-Immediate Initialize-Drive-Parameters NOP Read-Buffer Read-DMA Read-Multiple Read-Sector(s) Read-Verify-Sector(s) Recalibrate Request-Sense Security-Disable-Password Security-Erase-Prepare Security-Erase-Unit Security-Freeze-Lock Security-Set-Password Security-Unlock Seek Set-Features SMART Set-Multiple-Mode Set-Sleep-Mode Set-WP#/PD#-Mode Standby ©2010 Greenliant Systems, Ltd Code E5H or 98H - - - 90H - - - C0H - Y Y E7H - - - 7 50H ...

Page 14

... Drive. This command has the same protocol as the Read-Sector(s) command. The parameter words in the buffer have the arrangement and meanings defined in Table 9. All reserved bits or words are zero. Table 9 gives the definition for each field in the Identify-Drive information. ©2010 Greenliant Systems, Ltd. 512 MByte / 1 GByte / 2 GByte NANDrive GLS85LD0512 / GLS85LD1001T / GLS85LD1002U ...

Page 15

... Vendor Unique 2 Default number of sectors per track 4 Number of sectors per device (Word 7 = MSW, Word 8 = LSW) 2 Vendor Unique 10 User-programmable serial number in ASCII 10 Greenliant preset, unique ID in ASCII 2 Buffer type 2 Vendor Unique 2 Vendor Unique 8 Firmware revision in ASCII. Big Endian Byte Order in Word 40 User Definable Model number ...

Page 16

... LBA translation mode. This field is only required by CF feature set support. Word 10-19: Serial Number The contents of this field are right justified and padded with spaces (20H). The right-most ten bytes are a Greenliant preset, unique ID. The left-most ten bytes are a user-programmable value with a default value of spaces. ©2010 Greenliant Systems, Ltd. ...

Page 17

... Word 54-56: Current Number of Cylinders, Heads, Sectors/Track These fields contains the current number of user addressable Cylinders, Heads, and Sectors/ Track in the current translation mode. Word 57-58: Current Capacity This field contains the product of the current cylinders times heads times sectors. ©2010 Greenliant Systems, Ltd. 17 Data Sheet S71382-05-000 05/10 ...

Page 18

... PIO modes the device is capable of supporting. Of these bits, bits [7:2] are Reserved for future PIO modes. Bit Function 0 1: NANDrive supports PIO Mode- NANDrive supports PIO Mode-4. Word 65: Minimum Multi-word DMA ©2010 Greenliant Systems, Ltd. 512 MByte / 1 GByte / 2 GByte NANDrive GLS85LD0512 / GLS85LD1001T / GLS85LD1002U 18 S71382-05-000 05/10 ...

Page 19

... DMARQ is negated could result in reduced throughput despite the faster cycle rate. Transfer at this rate does not ensure that flow control will not be used, but implies that higher performance may result. Greenliant’s NANDrive supports up to Multi-word DMA Mode-2, so this field is set to 120 ns. ...

Page 20

... The values in this word should not be depended on by host implementers. Bit Function 15 0: Provides indication that the features/command sets supported words are valid 14 1: Provides indication that the features/command sets supported words are valid ©2010 Greenliant Systems, Ltd. 512 MByte / 1 GByte / 2 GByte NANDrive GLS85LD0512 / GLS85LD1001T / GLS85LD1002U 20 S71382-05-000 05/10 ...

Page 21

... Removable Media Status feature set is not enabled 3 0: Advanced Power Management feature set is not enabled 2 0: CFA feature set is disabled 1 0: Read DMA Queued and Write DMA Queued commands are not enabled 0 0: Download Microcode command is not enabled ©2010 Greenliant Systems, Ltd. 21 Data Sheet S71382-05-000 05/10 ...

Page 22

... Word 89: Time required for Security erase unit completion Word 89 specifies the time required for the Security Erase Unit command to complete. Value Time 0 Value not specified 1-254 (Value * 2) minutes 255 >508 minutes ©2010 Greenliant Systems, Ltd. 512 MByte / 1 GByte / 2 GByte NANDrive GLS85LD0512 / GLS85LD1001T / GLS85LD1002U 22 S71382-05-000 05/10 ...

Page 23

... Identity drive command executes, the device returns 0492H. Bit Function 2-0 Advanced True IDE PIO Mode Support Indicates the maximum True IDE PIO mode supported by the card Value Time 0 Specified in word 64 1 PIO Mode 5 2 PIO Mode 6 3-7 Reserved ©2010 Greenliant Systems, Ltd. 23 Data Sheet S71382-05-000 05/10 ...

Page 24

... Cyl High (5) Cyl Low (4) Sec Num (3) Sec Cnt (2) Feature (1) This command is used by the host to establish or select certain features. Table 10 defines all fea- tures that are supported. ©2010 Greenliant Systems, Ltd. 512 MByte / 1 GByte / 2 GByte NANDrive GLS85LD0512 / GLS85LD1001T / GLS85LD1002U EFH ...

Page 25

... PIO default mode PIO default mode, disable IORDY PIO flow control transfer mode Multi-word DMA mode Ultra-DMA mode Reserved 1. Mode = transfer mode number, all other values are not valid ©2010 Greenliant Systems, Ltd. -D data bus and the IOCS16 Bits [7:3] Bits [2:0] ...

Page 26

... Sleep mode is also entered when internal timers expire so the host does not need to issue this command except when it wishes to enter Sleep mode immedi- ately. The default value for the timer is 15 milliseconds. ©2010 Greenliant Systems, Ltd. 512 MByte / 1 GByte / 2 GByte NANDrive GLS85LD0512 / GLS85LD1001T / GLS85LD1002U ...

Page 27

... Once the mode is set with this command, the device will stay in the configured mode until the next time this command is issued. Power-off or reset will not change the configured mode. ©2010 Greenliant Systems, Ltd ...

Page 28

... Write-Multiple-Without-Erase Write-Sector(s) Write-Sector(s)-Without- Erase Write-Verify Invalid-Command-Code 1. The host is required to reissue any media access command (such as Read-Sector and Write Sector) that ends with an error condition. ©2010 Greenliant Systems, Ltd. 512 MByte / 1 GByte / 2 GByte NANDrive GLS85LD0512 / GLS85LD1001T / GLS85LD1002U 1 Error Register ABR BBK ...

Page 29

... Range Temperature Industrial -40°C to +85°C Table 10: AC Conditions of Test Input Rise/Fall Time See Figure 4 ©2010 Greenliant Systems, Ltd. 1 I3, I4, O4, and O5 to Ground Potential . . . . . . . . . . . . . . . . . -0. I3, I4, O4, and O5 to Ground Potential . . . . . . -2. I1, I2, O1, O2, and O6 to Ground Potential . . . . . . . . . . . . -0. I1, I2, O1, O2, and O6 to Ground Potential . -2. 25° ...

Page 30

... Symbol Parameter 1 I Latch Up LTH 1. This parameter is measured only for initial qualification and after a design or process change that could affect this parameter. ©2010 Greenliant Systems, Ltd. 512 MByte / 1 GByte / 2 GByte NANDrive GLS85LD0512 / GLS85LD1001T / GLS85LD1002U Typical 3 sec + (0.5 sec/ GByte) 200 200 Test Condition ...

Page 31

... OH6 V OL6 I Output Current for DASP# pin OH6 O6 I Output Current for DASP# pin OL6 I Output Current for DASP# pin OH6 I Output Current for DASP# pin OL6 ©2010 Greenliant Systems, Ltd. (GLS85LD0512/1001T/1002U DDQ Min Max Units Conditions 2 DDQ 0.8 V DDQ -10 ...

Page 32

... AC test inputs are driven at V Measurement reference points for inputs and outputs are Input rise and fall times (10% DD Figure 2: AC Input/Output Reference Waveforms ©2010 Greenliant Systems, Ltd. 512 MByte / 1 GByte / 2 GByte NANDrive GLS85LD0512 / GLS85LD1001T / GLS85LD1002U 1,2 PWR Power supply current -40° ...

Page 33

... MByte / 1 GByte / 2 GByte NANDrive GLS85LD0512 / GLS85LD1001T / GLS85LD1002U Appendix Differences between the Greenliant NANDrive and ATA-6 Specifications Idle Timer The Idle timer uses an incremental value of 5 ms, rather than the 5 sec minimum increment value specified in ATA specifications. Recovery from Sleep Mode For NANDrive devices, recovery from sleep mode is accomplished by simply issuing another com- mand to the device. A hardware or software reset is not required. © ...

Page 34

... UDMA Mode - 4 Higher letter indicates higher performance 512 = 512 MByte 001 = 1 GByte 002 = 2 GByte 0 = MByte 1 = GByte NANDrive der. Greenliant non-Pb solder devices are “RoHS Compliant”. GLS85LD1002U-60-RI-LBTE representative to confirm avail- ability of valid combinations and to determine availability of new combinations. S71382-05-000 05/10 ...

Page 35

... A1 CORNER 7 DETAIL 0.40 ± 0.05 SEATING PLANE Figure 1: mini-NANDrive 91-Ball Low Profile Ball Grid Array (LBGA) Greenliant Package Code: LBT ©2010 Greenliant Systems, Ltd. TOP VIEW 24.0 ±0.1 BOTTOM VIEW 9.0 1.0 1 ...

Page 36

... Data Sheet Table 1: Revision History Number • Initial release for SST85LD0512/SST85LD1001T/SSTLD1002U Data Sheet 00 01 • Added 5I (100M cycle endurance) information including updates in “Features” , “Gen- eral Description” , “Capacity Specification” , “Lifetime Expectancy” , “Software Inter- face” “Electrical Specifications” , and “Product Ordering Information” , • ...

Related keywords