ADP5062CP-EVALZ Analog Devices, ADP5062CP-EVALZ Datasheet - Page 23

no-image

ADP5062CP-EVALZ

Manufacturer Part Number
ADP5062CP-EVALZ
Description
Power Management IC Development Tools ADP5062 Evaluation board
Manufacturer
Analog Devices
Type
Linear Regulators - Standardr
Series
ADP5062r
Datasheet

Specifications of ADP5062CP-EVALZ

Rohs
yes
Product
Evaluation Boards
Tool Is For Evaluation Of
ADP5062
Input Voltage
4 V to 6.7 V
Description/function
Battery charger (isolated flyback)
Interface Type
I2C
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Output Current
2.1 A
Factory Pack Quantity
1
For Use With
ADP5062
JEITA2 Cold Temperature Limits
JEITA2 Cool Temperature Limits
JEITA2 Typical Temperature Limits
JEITA2 Warm Temperature Limits
JEITA2 Hot Temperature Limits
Data Sheet
JEITA Li-Ion Battery Temperature Charging Specification
The
battery charging temperature specifications as outlined in Table 14
and Table 16, respectively.
JEITA function can be enabled via the I
the JEITA1 or JEITA2 function can be selected in I
Table 14. JEITA1 Specifications
Parameter
JEITA1 Cold Temperature Limits
JEITA1 Cool Temperature Limits
JEITA1 Typical Temperature Limits
JEITA1 Warm Temperature Limits
JEITA1 Hot Temperature Limits
Table 15. JEITA1 Reduced Charge Current Levels, Battery Cool Temperature
ICHG[4:0] (Default)
00000 = 50 mA
00001 = 100 mA
00010 = 150 mA
00011 = 200 mA
00100 = 250 mA
00101 = 300 mA
00110 = 350 mA
00111 = 400 mA
01000 = 450 mA
01001 = 500 mA
01010 = 550 mA
01011 = 600 mA
Table 16. JEITA2 Specifications
Parameter
ADP5062
is compliant with the JEITA1 and JEITA2 Li-Ion
Symbol
I
I
I
I
I
Symbol
I
I
I
I
I
JEITA_COLD
JEITA_COOL
JEITA_TYP
JEITA_WARM
JEITA_HOT
ICHG JEITA1
50 mA
50 mA
50 mA
100 mA
100 mA
150 mA
150 mA
200 mA
200 mA
250 mA
250 mA
300 mA
JEITA_COLD
JEITA_COOL
JEITA_TYP
JEITA_WARM
JEITA_HOT
2
C interface and, optionally,
Conditions
No battery charging occurs.
Battery charging occurs at approximately 50% of the programmed
level. See Table 15 for specific charging current reduction levels.
Normal battery charging occurs at the default/programmed levels.
Battery termination voltage (V
programmed value.
No battery charging occurs.
No battery charging occurs.
Battery termination voltage (V
programmed value.
Normal battery charging occurs at the default/programmed levels.
Battery termination voltage (V
programmed value.
No battery charging occurs.
Conditions
2
C.
Rev. 0 | Page 23 of 44
ICHG[4:0] (Default)
01100 = 650 mA
01101 = 700 mA
01110 = 750 mA
01111 = 800 mA
10000 = 850 mA
10001 = 900 mA
10010 = 950 mA
10011 = 1000 mA
10100 = 1050 mA
10101 = 1100 mA
10110 = 1200 mA
10111 = 1300 mA
Alternatively, the JEITA1 or JEITA2 can be set as enabled to
default by factory programming.
When the
the
ADP5062
TRM
TRM
TRM
Stops charging the battery.
Connects or enables the battery isolation FET such that the
ADP5062
) is reduced by 100 mV from the
) is reduced by 100 mV from the
) is reduced by 100 mV from the
ADP5062
takes the following actions:
continues in LDO mode.
identifies a hot or cold battery condition,
ICHG JEITA1
300 mA
350 mA
350 mA
400 mA
400 mA
450 mA
450 mA
500 mA
500 mA
550 mA
600 mA
650 mA
Min
0
10
45
60
Min
0
10
45
60
ADP5062
0
10
45
60
Max
Max
0
10
45
60
Unit
°C
°C
°C
°C
°C
Unit
°C
°C
°C
°C
°C

Related parts for ADP5062CP-EVALZ