Specifications of M29W160EB70ZA6F

Format - Memory
FLASH
Memory Type
FLASH - Nor
Memory Size
16M (2M x 8 or 1M x 16)
Speed
70ns
Interface
Parallel
Voltage - Supply
2.7 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Package / Case
48-TFBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M29W160EB70ZA6F
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Company:
Part Number:
M29W160EB70ZA6F
Quantity:
6 067
FEATURES SUMMARY
June 2009
SUPPLY VOLTAGE
ACCESS TIMES: 70, 90ns
PROGRAMMING TIME
35 MEMORY BLOCKS
PROGRAM/ERASE CONTROLLER
ERASE SUSPEND and RESUME MODES
UNLOCK BYPASS PROGRAM COMMAND
TEMPORARY BLOCK UNPROTECTION
MODE
COMMON FLASH INTERFACE
LOW POWER CONSUMPTION
100,000 PROGRAM/ERASE CYCLES per
BLOCK
ELECTRONIC SIGNATURE
Automotive Grade Parts Available
V
and Read
10μs per Byte/Word typical
1 Boot Block (Top or Bottom Location)
2 Parameter and 32 Main Blocks
Embedded Byte/Word Program
algorithms
Read and Program another Block during
Erase Suspend
Faster Production/Batch Programming
64 bit Security Code
Standby and Automatic Standby
Manufacturer Code: 0020h
Top Device Code M29W160ET: 22C4h
Bottom Device Code M29W160EB: 2249h
CC
= 2.7V to 3.6V for Program, Erase
16 Mbit (2Mb x8 or 1Mb x16, Boot Block)
Figure 1. Packages
3V Supply Flash Memory
FBGA64 (ZS)
11 x 13 mm
TFBGA48 (ZA)
TSOP48 (N)
12 x 20mm
6 x 8mm
M29W160EB
M29W160ET
FBGA
BGA
1/42

Related parts for M29W160EB70ZA6F

M29W160EB70ZA6F Summary of contents

Page 1

... Manufacturer Code: 0020h – Top Device Code M29W160ET: 22C4h – Bottom Device Code M29W160EB: 2249h Automotive Grade Parts Available June 2009 16 Mbit (2Mb x8 or 1Mb x16, Boot Block) 3V Supply Flash Memory Figure 1. Packages M29W160ET M29W160EB TSOP48 ( 20mm FBGA TFBGA48 (ZA 8mm ...

Page 2

M29W160ET, M29W160EB TABLE OF CONTENTS FEATURES SUMMARY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

Page 3

Unlock Bypass Reset Command ...

Page 4

M29W160ET, M29W160EB PART NUMBERING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

Page 5

... Program or Erase commands from modifying the memory. Program and Erase commands are writ- ten to the Command Interface of the memory. An on-chip Program/Erase Controller simplifies the process of programming or erasing the memory by taking care of all of the special operations that are required to update the memory contents ...

Page 6

M29W160ET, M29W160EB Figure 3. TSOP Connections 6/42 A15 1 48 A14 A13 A12 A11 A10 A9 A8 A19 M29W160ET M29W160EB A18 A17 ...

Page 7

Figure 4. TFBGA Connections (Top view through package A17 A18 ...

Page 8

M29W160ET, M29W160EB Figure 5. FBGA 64-ball Connections (Top view through package 8/42 ...

Page 9

Figure 6. Block Addresses (x8) M29W160ET Top Boot Block Addresses (x8) 1FFFFFh 16 KByte 1FC000h 1FBFFFh 8 KByte 1FA000h 1F9FFFh 8 KByte 1F8000h 1F7FFFh 32 KByte 1F0000h 1EFFFFh 64 KByte 1E0000h 01FFFFh 64 KByte 010000h 00FFFFh 64 KByte 000000h Note: ...

Page 10

M29W160ET, M29W160EB Figure 7. Block Addresses (x16) M29W160ET Top Boot Block Addresses (x16) FFFFFh 8 KWord FE000h FDFFFh 4 KWord FD000h FCFFFh 4 KWord FC000h FBFFFh 16 KWord F8000h F7FFFh 32 KWord F0000h 0FFFFh 32 KWord 08000h 07FFFh 32 KWord ...

Page 11

... Names, for a brief overview of the signals connect this device. Address Inputs (A0-A19). The Address Inputs select the cells in the memory array to access dur- ing Bus Read operations. During Bus Write opera- tions they control the commands sent to the Command Interface of the Program/Erase Con- troller ...

Page 12

... Disable, Standby and Automatic Standby. See Tables 2 and 3, Bus Operations, for a summary. Typically glitches of less than 5ns on Chip Enable or Write Enable are ignored by the memory and do not affect bus operations. Bus Read. Bus Read operations read from the memory cells, or specific registers in the Com- mand Interface ...

Page 13

... From the Auto Select mode the Manufacturer Code can be read using a Bus Read operation with may be set to either V Code for Numonyx is 0020h. The Device Code can be read using a Bus Read operation with address bits may be set to either V Device Code for the M29W160ET is 22C4h and for the M29W160EB is 2249h ...

Page 14

... Once the Unlock Bypass command has been is- sued the memory will only accept the Unlock By- pass Program command and the Unlock Bypass Reset command. The memory can be read Read mode. Unlock Bypass Program Command. The lock Bypass Program command can be used to program one address in memory at a time ...

Page 15

... Erase Suspend Latency Time (refer to Table 6 for value) of the Erase Suspend Command being issued. Once the Program/Erase Controller has stopped the memory will be set to Read mode and the Erase will be suspended. If the Erase Suspend command is issued during the period when the ...

Page 16

... Unlock Bypass. After the Unlock Bypass command issue Unlock Bypass Program or Unlock Bypass Reset commands. Unlock Bypass Reset. After the Unlock Bypass Reset command read the memory as normal until another command is issued. Erase Suspend. After the Erase Suspend command read non-erasing memory blocks as normal, issue Auto Select and Program com- mands on non-erasing blocks as normal. ...

Page 17

... Unlock Bypass. After the Unlock Bypass command issue Unlock Bypass Program or Unlock Bypass Reset commands. Unlock Bypass Reset. After the Unlock Bypass Reset command read the memory as normal until another command is issued. Erase Suspend. After the Erase Suspend command read non-erasing memory blocks as normal, issue Auto Select and Program com- mands on non-erasing blocks as normal. ...

Page 18

... Program/Erase Controller. The Error Bit is set to ’1’ when a Pro- gram, Block Erase or Chip Erase operation fails to write the correct data to the memory. If the Error Bit is set a Read/Reset command must be issued before other commands are issued. The Error bit is output on DQ5 when the Status Register is read ...

Page 19

... One of the Erase commands must be used to set all the bits in a block or in the whole memory from ’0’ to ’1’ Erase Timer Bit (DQ3). The Erase Timer Bit can be used to identify the start of Program/Erase Controller operation during a Block Erase com- mand ...

Page 20

... AI03598 stress ratings only and operation of the device at these or any other conditions above those indicat the Operating sections of this specification is not implied. Refer also to the Numonyx SURE Pro- gram and other relevant quality documents. Parameter (1,2) +2V during transition and for less than 20ns during transitions. ...

Page 21

DC AND AC PARAMETERS This section summarizes the operating measure- ment conditions, and the DC and AC characteris- tics of the device. The parameters in the DC and AC characteristics Tables that follow, are derived from tests performed under the ...

Page 22

M29W160ET, M29W160EB Table 10. Device Capacitance Symbol Parameter C Input Capacitance IN C Output Capacitance OUT Note: Sampled only, not 100% tested. Table 11. DC Characteristics Symbol Parameter I Input Leakage Current LI I Output Leakage Current LO I Supply ...

Page 23

Figure 12. Read Mode AC Waveforms A0-A19/ A– DQ0-DQ7/ DQ8-DQ15 BYTE tELBL/tELBH Table 12. Read AC Characteristics Symbol Alt t t Address Valid to Next Address Valid AVAV Address Valid to Output Valid AVQV ACC ...

Page 24

M29W160ET, M29W160EB Figure 13. Write AC Waveforms, Write Enable Controlled A0-A19/ A– DQ0-DQ7/ DQ8-DQ15 V CC tVCHEL RB Table 13. Write AC Characteristics, Write Enable Controlled Symbol Alt t t Address Valid to Next Address Valid AVAV ...

Page 25

Figure 14. Write AC Waveforms, Chip Enable Controlled A0-A19/ A– DQ0-DQ7/ DQ8-DQ15 V CC tVCHWL RB Table 14. Write AC Characteristics, Chip Enable Controlled Symbol Alt t t Address Valid to Next Address Valid AVAV WC t ...

Page 26

M29W160ET, M29W160EB Figure 15. Reset/Block Temporary Unprotect AC Waveforms tPLPX RP Table 15. Reset/Block Temporary Unprotect AC Characteristics Symbol Alt (1) t PHWL RP High to Write Enable Low, Chip Enable Low PHEL RH ...

Page 27

PACKAGE MECHANICAL Figure 16. TSOP48 – 48 lead Plastic Thin Small Outline 20mm, Package Outline, top view DIE Note: Drawing is not to scale. Table 16. TSOP48 – 48 lead Plastic Thin Small ...

Page 28

M29W160ET, M29W160EB Figure 17. TFBGA48 6x8mm - 6x8 ball array, 0.80 mm pitch, Package Outline, bottom view FE BALL "A1" Table 17. TFBGA48 6x8mm - 6x8 ball array, 0.80 mm pitch, Package Mechanical Data Symbol Typ A A1 ...

Page 29

Figure 18. FBGA64 mm— active ball array pitch, package outline, bottom view BALL "A1" A Table 18. FBGA64 mm— active ball array ...

Page 30

... F = RoHS, Tape & Reel Packing Devices are shipped from the factory with the memory content bits erased to ’1’. For a list of available options (Speed, Package, etc.) or for further information on any aspect of this device, please contact the Numonyx Sales Office nearest to you. 30/42 M29W160EB ...

Page 31

APPENDIX A. BLOCK ADDRESS TABLE Table 20. Top Boot Block Addresses, M29W160ET Size Address Range # (KBytes) (x8 1FC000h-1FFFFFh 33 8 1FA000h-1FBFFFh 32 8 1F8000h-1F9FFFh 31 32 1F0000h-1F7FFFh 30 64 1E0000h-1EFFFFh 29 64 1D0000h-1DFFFFh 28 64 1C0000h-1CFFFFh 27 ...

Page 32

... Table 27, Security Code area). This area can be accessed only in Read mode by the final user impossible to change the security num- ber after it has been written by Numonyx. Issue a Read command to return to Read mode. Note: The Common Flash Interface is only avail- able for Temperature range 6 (–40 to 85°C). ...

Page 33

Table 24. CFI Query System Interface Information Address Data x16 x8 1Bh 36h 0027h 1Ch 38h 0036h 1Dh 3Ah 0000h 1Eh 3Ch 0000h 1Fh 3Eh 0004h 20h 40h 0000h 21h 42h 000Ah 22h 44h 0000h 23h 46h 0004h 24h 48h ...

Page 34

M29W160ET, M29W160EB Table 25. Device Geometry Definition Address Data x16 x8 27h 4Eh 0015h 28h 50h 0002h 29h 52h 0000h 2Ah 54h 0000h 2Bh 56h 0000h 2Ch 58h 0004h 2Dh 5Ah 0000h 2Eh 5Ch 0000h 2Fh 5Eh 0040h 30h 60h ...

Page 35

Table 26. Primary Algorithm-Specific Extended Query Table Address Data x16 x8 40h 80h 0050h 41h 82h 0052h 42h 84h 0049h 43h 86h 0031h 44h 88h 0030h 45h 8Ah 0000h 46h 8Ch 0002h 47h 8Eh 0001h 48h 90h 0001h 49h 92h ...

Page 36

... Reset/Blocks Temporary Unprotect pin, RP. This can be achieved without violating the maximum ratings of the components on the micro- processor bus, therefore this technique is suitable for use after the Flash memory has been fitted to the system. ) volt protect a block follow the flowchart in Figure 21, In-System Block Protect Flowchart ...

Page 37

Figure 19. Programmer Equipment Block Protect Flowchart Note: 1. Address Inputs A19-A12 give the address of the block that protected imperative that they remain stable during the operation. 2. During the Protect and Verify phases ...

Page 38

M29W160ET, M29W160EB Figure 20. Programmer Equipment Chip Unprotect Flowchart NO = 1000 38/42 START PROTECT ALL BLOCKS CURRENT BLOCK = 0 A6, A12, A15 = V IH (1) ...

Page 39

Figure 21. In-System Equipment Block Protect Flowchart START WRITE 60h ADDRESS = BLOCK ADDRESS WRITE 60h ADDRESS = BLOCK ...

Page 40

M29W160ET, M29W160EB Figure 22. In-System Equipment Chip Unprotect Flowchart NO = 1000 ISSUE READ/RESET COMMAND FAIL 40/42 START PROTECT ALL BLOCKS CURRENT BLOCK = WRITE 60h ANY ADDRESS ...

Page 41

... Appendix C, BLOCK PROTECTION. TSOP48 package information updated (see Figure 16 and Table 16). Block Erase Command clarified. Applied Numonyx branding. Added FBGA (ZS) package and ballout information. Revised Chip Erase signal value (maximum) in Table 6., Program/Erase Times and Program/Erase Endurance Cycles from 120 to 60 seconds Revised Block Erase (64-Kbytes) signal value (maximum) in Table 6 ...

Page 42

... WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT Numonyx products are not intended for use in medical, life saving, life sustaining, critical control or safety systems nuclear facility applications. Numonyx may make changes to specifications and product descriptions at any time, without notice. ...