M29DW128F60ZA6E NUMONYX, M29DW128F60ZA6E Datasheet - Page 53

no-image

M29DW128F60ZA6E

Manufacturer Part Number
M29DW128F60ZA6E
Description
IC FLASH 128MBIT 60NS 64TBGA
Manufacturer
NUMONYX
Series
Axcell™r
Datasheet

Specifications of M29DW128F60ZA6E

Format - Memory
FLASH
Memory Type
FLASH - Nor
Memory Size
128M (16Mx8, 8Mx16)
Speed
60ns
Interface
Parallel
Voltage - Supply
2.7 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Package / Case
64-TBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M29DW128F60ZA6E
Manufacturer:
SIPEX
Quantity:
1 492
Part Number:
M29DW128F60ZA6E
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Part Number:
M29DW128F60ZA6E
Manufacturer:
ST
0
M29DW128F
8
The Multiple Bank Architecture of the M29DW128F gives greater flexibility for software developers to split
the code and data spaces within the memory array. The Dual Operations feature simplifies the software
management of the device by allowing code to be executed from one bank while another bank is being
programmed or erased.
The Dual Operations feature means that while programming or erasing in one bank, read operations are
possible in another bank with zero latency.
Only one bank at a time is allowed to be in program or erase mode. However, certain commands can
cross bank boundaries, which means that during an operation only the banks that are not concerned with
the cross bank operation are available for dual operations. For example, if a Block Erase command is
issued to erase blocks in both Bank A and Bank B, then only Banks C or D are available for read
operations while the erase is being executed.
If a read operation is required in a bank, which is programming or erasing, the program or erase
operation can be suspended.
Also if the suspended operation was erase then a program command can be issued to another block, so
the device can have one block in Erase Suspend mode, one programming and other banks in read mode.
By using a combination of these features, read operations are possible at any moment.
Table 20
only the commonly used commands are represented in these tables.
Table 20.
1. If several banks are involved in a program or erase operation, then only the banks that are not concerned with the
2. Read Status Register is not a command. The Status Register can be read during a block program or erase operation.
3. Only after a program or erase operation in that bank.
4. Only after a Program or Erase Suspend command in that bank.
5. Only a Program Resume is allowed if the bank was previously in Program Suspend mode.
6. Only an Erase Resume is allowed if the bank was previously in Erase Suspend mode.
Idle
Programming
Erasing
Program Suspended
Erase Suspended
Status of Bank
operation are available for dual operations.
and
Dual Operations and Multiple Bank architecture
Dual Operations allowed in other Banks
Table 21
Read/
Reset
show the dual operations possible in other banks and in the same bank. Note that
Yes
Yes
Yes
Yes
Yes
Register
Status
Yes
Read
No
No
No
No
(3)
(2)
Read CFI
Query
Commands allowed in another bank
Yes
Yes
Yes
No
No
Dual Operations and Multiple Bank architecture
Select
Auto
(1)
Yes
Yes
Yes
No
No
Program
Yes
Yes
No
Erase
Yes
No
No
Program/
Suspend
Erase
Yes
No
No
-
-
(3)
Program/
Resume
Erase
Yes
Yes
Yes
No
No
53/94
(4)
(5)
(6)

Related parts for M29DW128F60ZA6E