M29DW128F70NF6E NUMONYX, M29DW128F70NF6E Datasheet - Page 19

no-image

M29DW128F70NF6E

Manufacturer Part Number
M29DW128F70NF6E
Description
IC FLASH 128MBIT 70NS 56TSOP
Manufacturer
NUMONYX
Series
Axcell™r
Datasheet

Specifications of M29DW128F70NF6E

Format - Memory
FLASH
Memory Type
FLASH - Nor
Memory Size
128M (16Mx8, 8Mx16)
Speed
70ns
Interface
Parallel
Voltage - Supply
2.7 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Package / Case
56-TSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M29DW128F70NF6E
Manufacturer:
ST
0
M29DW128F
3.5
3.6
3.6.1
3.6.2
3.6.3
3.6.4
Automatic Standby
If CMOS levels (V
more the memory enters Automatic Standby where the internal Supply Current is reduced to
the Standby Supply Current, I
Read operation is in progress.
Special Bus operations
Additional bus operations can be performed to read the Electronic Signature, verify the
Protection Status of the Extended Memory Block (second section), and apply and remove
Block Protection. These bus operations are intended for use by programming equipment
and are not usually used in applications. They require V
Read Electronic Signature
The memory has two codes, the Manufacturer code and the Device code used to identify
the memory. These codes can accessed by performing read operations with control signals
and addresses set as shown in
issuing an Auto Select command (see
Verify Extended Block Protection Indicator
The Extended Block is divided in two sections of which one is Factory Locked and the
second one is either Customer Lockable or Customer Locked.
The Protection Status of the second section of the Extended Block (Customer Lockable or
Customer Locked) can be accessed by reading the Extended Block Protection Indicator.
This is performed by applying the signals as shown in
Status of the Extended Block is then output on bits DQ7 and DQ6 of the Data Input/Outputs.
(see
The Protection Status of the Extended Block can also be accessed by issuing an Auto
Select command (see
Verify Block Protection Status
The Protection Status of a Block can be directly accessed by performing a read operation
with control signals and addresses set as shown in
protected, then 01h (in x8 mode) is output on Data Input/Outputs DQ0-DQ7, otherwise 00h
is output.
Hardware Block Protect
The V
is at V
of the Block Protection Status or the Reset/Block Temporary Unprotect pin state.
Table 3
PP
IL
the four outermost parameter blocks are protected and remain protected regardless
/WP pin can be used to protect the four outermost parameter blocks. When V
and
Table
CC
± 0.2V) are used to drive the bus and the bus is inactive for 300ns or
Section 6.1.2: Auto Select
6, Bus Operations).
CC2
Table 4
. The Data Inputs/Outputs will still output data if a Bus
Section 6.1.2: Auto Select
and
Table
command).
6. These codes can also be accessed by
Table 5
Table 5
ID
to be applied to some pins.
and
and
Table
command).
Table
8. If the Block is
8. The Protection
Bus operations
PP
19/94
/WP

Related parts for M29DW128F70NF6E