M29DW128F70ZA6F NUMONYX, M29DW128F70ZA6F Datasheet - Page 39

no-image

M29DW128F70ZA6F

Manufacturer Part Number
M29DW128F70ZA6F
Description
IC FLASH 128MBIT 70NS 64TBGA
Manufacturer
NUMONYX
Series
Axcell™r
Datasheet

Specifications of M29DW128F70ZA6F

Format - Memory
FLASH
Memory Type
FLASH - Nor
Memory Size
128M (16Mx8, 8Mx16)
Speed
70ns
Interface
Parallel
Voltage - Supply
2.7 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Package / Case
64-TBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M29DW128F70ZA6F
Manufacturer:
HY
Quantity:
300
Part Number:
M29DW128F70ZA6F
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Part Number:
M29DW128F70ZA6F
Manufacturer:
ST
0
M29DW128F
6.2.10
The Unlock Bypass Program command can be used to program one address in the memory array at a
time. The command requires two Bus Write operations, the final write operation latches the address and
data and starts the Program/Erase Controller.
The Program operation using the Unlock Bypass Program command behaves identically to the Program
operation using the Program command. The operation cannot be aborted, a Bus Read operation to the
Bank where the command was issued outputs the Status Register. See the Program command for details
on the behavior.
6.2.11
The Unlock Bypass Reset command can be used to return to Read/Reset mode from Unlock Bypass
mode. Two Bus Write operations are required to issue the Unlock Bypass Reset command. Read/Reset
command does not exit from Unlock Bypass mode.
Table 13.
1.
2.
3.
4.
5.
Write to Buffer
and Program
Write to Buffer
and Program
Abort and
Reset
Write to Buffer
and Program
Confirm
Double byte
Program
Quadruple byte
Program
Octuple byte
Program
Unlock Bypass
Unlock Bypass
Program
Unlock Bypass
Reset
Command
X Don’t Care, PA Program Address, PD Program Data, BA Any address in the Block, BKA Bank Address, WBL Write Buffer Location. All
values in the table are in hexadecimal.
The maximum number of cycles in the command sequence is 68. N+1 is the number of bytes to be programmed during the Write to Buffer
and Program operation.
Each buffer has the same A5-A22 addresses. A0-A4 and A-1 are used to select a byte within the N+1 byte page.
The 6th cycle has to be issued N time. WBL scans the byte inside the page.
BA must be identical to the address loaded during the Write to buffer and Program 3rd and 4th cycles.
Unlock Bypass Program command
Unlock Bypass Reset command
Fast Program Commands, 8-bit mode
N
+
5
3
1
3
5
9
3
2
2
AAA
AAA
AAA
AAA
AAA
AAA
Add
BA
(5)
X
X
1st
Data
AA
AA
AA
8B
A0
29
50
56
90
Add Data
PA0
PA0
PA0
555
555
555
PA
X
2nd
PD0
PD0
PD0
PD
55
55
55
00
Add
AAA
AAA
PA1
PA1
PA1
BA
3rd
Data Add
PD1
PD1
PD1
F0
25
20
PA2
PA2
BA
4th
Data
PD2
PD2
N
(2)
Bus Write operations
(1)
Add
PA3
PA3
PA
(3)
5th
Data
PD3
PD3
PD
WBL
Add
PA4
(4)
6th
Data
PD4
PD
Add
PA5
7th
Data
PD5
Command interface
Add
PA6
8th
Data
PD6
Add
PA7
9th
39/94
Data
PD7

Related parts for M29DW128F70ZA6F