M58BW016DB7T3TNX NUMONYX, M58BW016DB7T3TNX Datasheet - Page 32

no-image

M58BW016DB7T3TNX

Manufacturer Part Number
M58BW016DB7T3TNX
Description
IC FLASH 16MBIT 70NS 80PQFP
Manufacturer
NUMONYX
Datasheet

Specifications of M58BW016DB7T3TNX

Format - Memory
FLASH
Memory Type
FLASH
Memory Size
16M (512K x 32)
Speed
70ns
Interface
Parallel
Voltage - Supply
2.7 V ~ 3.6 V
Operating Temperature
-40°C ~ 125°C
Package / Case
80-MQFP, 80-PQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
M58BW016DB7T3TNXCT

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M58BW016DB7T3TNX
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Command interface
4.10
32/70
Set Burst Configuration Register command
The Set Burst Configuration Register command is used to write a new value to the burst
configuration control register which defines the burst length, type, X and Y latencies,
synchronous/asynchronous read mode and the valid clock edge configuration.
Two bus write cycles are required to issue the Set Burst Configuration Register command.
The first cycle writes the setup command and the address corresponding to the set burst
configuration register content. The second cycle writes the burst configuration register data
and the confirm command. Once the command is issued the memory returns to read mode
as if a Read Memory Array command had been issued.
The value for the burst configuration register is always presented on A0-A15. M0 is on A0,
M1 on A1, etc.; the other address bits are ignored.
Table 9.
1. X = Don’t care; RA = Read Address, RD = Read Data, ID = Device Code, SRD = Status Register Data, PA
Read Memory Array
Read Electronic Signature
(manufacturer code)
Read Electronic Signature
(device code)
Read Electronic Signature
(burst configuration register)
Read Status Register
Read Query
Clear Status Register
Block Erase
Program
Program/Erase Suspend
Program/Erase Resume
Set Burst Configuration Register
= Program Address; PD = Program Data, QA = Query Address, QD = Query Data, BA = Any address in the
Block, BCR = Burst Configuration Register value.
Command
Commands
(1)
M58BW016DT, M58BW016DB, M58BW016FT, M58BW016FB
2
1
2
2
1
1
2
2
2
2
2
2
Write
Write
Write
Write
Write
Write
Write
Write
Write
Write
Write
Write
Op.
1st cycle
Addr.
X
X
X
X
X
X
X
X
X
X
X
X
Bus operations
Data
FFh
B0h
D0h
90h
90h
90h
70h
98h
50h
20h
40h
10h
60h
Read
Read
Read
Read
Read
Read
Write
Write
Write
Op.
2nd cycle
00000h
00001h
00005h
BCRh
Addr.
QAh
BAh
RA
PA
X
BCRh
SRDh
Data
QDh
D0h
20h
03h
RD
IDh
PD

Related parts for M58BW016DB7T3TNX