VIPER16LDTR STMicroelectronics, VIPER16LDTR Datasheet - Page 18

IC OFFLINE CONV PWM OTP 16SOIC

VIPER16LDTR

Manufacturer Part Number
VIPER16LDTR
Description
IC OFFLINE CONV PWM OTP 16SOIC
Manufacturer
STMicroelectronics
Series
VIPer™ plusr
Datasheet

Specifications of VIPER16LDTR

Output Isolation
Either
Frequency Range
54 ~ 66kHz
Voltage - Input
11.5 ~ 23.5 V
Voltage - Output
800V
Power (watts)
12W
Operating Temperature
-40°C ~ 150°C
Package / Case
16-SOIC (0.154", 3.90mm Width)
For Use With
497-9006 - BOARD EVAL BASED ON VIPER16497-8838 - EVAL BOARD FOR VIPER16LD497-8837 - EVAL BOARD FOR VIPER16LD ISO PSU
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-8829-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
VIPER16LDTR
Manufacturer:
STM
Quantity:
2 188
Part Number:
VIPER16LDTR
Manufacturer:
ST
Quantity:
20 000
Part Number:
VIPER16LDTR
0
Company:
Part Number:
VIPER16LDTR
Quantity:
30 000
Company:
Part Number:
VIPER16LDTR
Quantity:
32 500
Open loop failure protection
15
18/24
Open loop failure protection
In case the power supply is built in fly-back topology and the VIPer16 is supplied by an
auxiliary winding, as shown in
converter is protected against feedback loop failure or accidental disconnections of the
winding.
The following description is applicable for the schematics of
Figure 28 on page
If R
voltage, V
output through the secondary-to-auxiliary turns ratio.
As the auxiliary voltage increases up to the internal V
reported on
latch threshold, I
generated.
In order to distinguish an actual malfunction from a bad auxiliary winding design, both the
above conditions (drain current equal to the drain current limitation and current higher than
I
If R
voltage V
case of isolated fly-back).
Figure 27. FB pin connection for non-isolated fly-back
DDol
H
L
is opened or R
through VDD clamp) have to be verified to reveal the fault.
is opened or R
REF_FB
OUT
Table 8 on page
, will increase and so the auxiliary voltage, V
R
R
H
L
DDol
(in case of non isolated fly-back) or to the external TL voltage reference (in
V
OUT
19, respectively the non-isolated fly-back and the isolated fly-back.
L
H
(the value is reported on
is shorted, the VIPer16 works at its drain current limitation. The output
is shorted, the output voltage, V
FB
C
VDD
7) and the clamp current injected on VDD pin exceeds the
V
Doc ID 15232 Rev 4
REF_FB
Figure 27 on page 18
VDD
-
+
E/A
C
COMP
P
BUS
Table 8 on page
R
C
S
S
nR
V
from R
COMPL
and
DD
R
OUT
SENSE
+
-
+
-
active clamp, V
Figure 28 on page
, will be clamped to the reference
AUX
Figure 27 on page 18
, which is coupled with the
PWM stop
to PWM
7), a fault signal is internally
R
AUX
DDclamp
D
AUX
19, the
(the value is
and
VIPER16
V
AUX

Related parts for VIPER16LDTR