ICE3A1065 Infineon Technologies, ICE3A1065 Datasheet - Page 18

no-image

ICE3A1065

Manufacturer Part Number
ICE3A1065
Description
IC OFFLINE CTRLR SMPS CM 8DIP
Manufacturer
Infineon Technologies
Series
CoolSET®F3r
Datasheet

Specifications of ICE3A1065

Output Isolation
Isolated
Frequency Range
92 ~ 108kHz
Voltage - Input
8.5 ~ 22 V
Voltage - Output
650V
Power (watts)
32W
Operating Temperature
-25°C ~ 130°C
Package / Case
8-DIP (0.300", 7.62mm)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
ICE3A1065X
ICE3A1065XK
SP000015074

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ICE3A1065
Manufacturer:
INFINEON
Quantity:
5 510
Part Number:
ICE3A1065
Manufacturer:
INFINEON
Quantity:
8 000
Part Number:
ICE3A1065
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
ICE3A1065ELJ
Manufacturer:
INFINEON
Quantity:
3 500
Part Number:
ICE3A1065ELJ
Quantity:
1 527
Part Number:
ICE3A1065ELJ
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Company:
Part Number:
ICE3A1065ELJ
Quantity:
4 800
Part Number:
ICE3A1065L
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
ICE3A1065LJ
Manufacturer:
INFINEON
Quantity:
619
CoolSET™-F3
Functional Description
consumption of the IC as much as possible. In this mode, the
average current consumption is only 300µA as the only
working block is the Undervoltage Lockout(UVLO) which
controls the Startup Cell by switching on/off at V
/
VCCon
V
.
VCCoff
As there is no longer a self supply by the auxiliary winding,
VCC starts to drop. The UVLO switches on the integrated
Startup Cell when VCC falls below 8.5V. It will continue to
charge VCC up to 15V whereby it is switched off again and
the IC enters into the Start Up Phase.
As long as all fault conditions have been removed, the IC
will automatically power up as usual with switching cycle at
the GATE output after Soft Start duration. Thus the name
Auto Restart Mode.
Other fault detections which are active in normal operation
is the sensing for Overload, Open Loop and VCC
undervoltage conditions. In the first 2 cases, FB will rise
above 4.8V which will be observed by C4. At this time, S1
is released such that V
can rise from its earlier clamp
SoftS
voltage of 4.4V. If V
exceeds 5.4V which is observed by
SoftS
C3, Auto Restart Mode is entered as both inputs of the gate
G5 are high.
This charging of the Soft Start capacitor from 4.4V to 5.4V
defines a blanking window which prevents the system from
entering into Auto Restart Mode un-intentionally during
large load jumps. In this event, FB will rise close to 6.5V for
a short duration before the loop regulates with FB less than
4.8V. This is the same blanking time window as for the
Active Burst Mode and can therefore be adjusted by the
external C
.
SoftS
In the case of VCC undervoltage, ie. VCC falls below 8.5V,
the IC will be turn off with the Startup Cell charging VCC as
described earlier in this section. Once VCC is charged above
15V, the IC will start a new startup cycle. The same
procedure applies when the system is under Short
Optocoupler fault condition, as it will lead to VCC
undervoltage.
Version 2.0
18
24 Aug 2005