BQ27505YZGR-J4

Manufacturer Part NumberBQ27505YZGR-J4
DescriptionIC BATT FUEL GAUGE LIION 12DSBGA
ManufacturerTexas Instruments
SeriesImpedance Track™
BQ27505YZGR-J4 datasheet
 


Specifications of BQ27505YZGR-J4

FunctionFuel, Gas Gauge/MonitorBattery TypeLithium-Ion (Li-Ion)
Voltage - Supply2.4 V ~ 2.6 VOperating Temperature-40°C ~ 85°C
Mounting TypeSurface MountPackage / Case12-UFBGA, WLCSP
Lead Free Status / RoHS StatusLead free / RoHS Compliant  
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
Page 21
22
Page 22
23
Page 23
24
Page 24
25
Page 25
26
Page 26
27
Page 27
28
Page 28
29
Page 29
30
Page 30
31
32
33
34
35
36
37
38
39
40
Page 25/40

Download datasheet (664Kb)Embed
PrevNext
www.ti.com
5.2.10 Avg I Last Run
The bq27505-J4 logs the current averaged from the beginning to the end of each discharge cycle. It stores
this average current from the previous discharge cycle in this register. This register should never need to
be modified. It is only updated by the bq27505-J4 when required.
5.2.11 Avg P Last Run
The bq27505-J4 logs the power averaged from the beginning to the end of each discharge cycle. It stores
this average power from the previous discharge cycle in this register. To get a correct average power
reading the bq27505-J4 continuously multiplies instantaneous current times Voltage( ) to get power. It
then logs this data to derive the average power. This register should never need to be modified. It is only
updated by the bq27505-J4 when required.
5.2.12 Delta Voltage
The bq27505-J4 stores the maximum difference of Voltage( ) during short load spikes and normal load, so
the Impedance Track™ algorithm can calculate remaining capacity for pulsed loads. This behavior can be
modified by setting bits 0 and 1 of the Data flash register Debug Options as follows:
Bit1
Bit0
Delta V Selection
0
0
Standard
0
1
No Averaging
1
0
Minimum Delta V
1
1
unused
5.2.13 Default Ra and Ra Tables
These tables contain encoded data and, with the exception of the Default Ra Tables, are automatically
updated during device operation. No user changes should be made except for reading/writing the values
from a pre-learned pack (part of the process for creating golden image files).
5.3
DETAILED PIN DESCRIPTION
5.3.1 The Operation Configuration Register
Some bq27505-J4 pins are configured via the Operation Configuration data flash register, as indicated
in
Table
5-3. This register is programmed/read via the methods described in
FLASH. The register is located at subclass = 64, offset = 0.
Copyright © 2009, Texas Instruments Incorporated
Description
Average variance from steady state voltage used to determine end of discharge voltage
Last instantaneous change in voltage from steady state used to determine end of discharge
voltage
Value in Min Delta Voltage used
Submit Documentation Feedback
bq27505-J4
SLVSA40 – DECEMBER 2009
ACCESSING THE DATA
FUNCTIONAL DESCRIPTION
25