ICL7136CPLZ Intersil, ICL7136CPLZ Datasheet - Page 7

IC ADC 3.5DIGIT LCD LP 40DIP

ICL7136CPLZ

Manufacturer Part Number
ICL7136CPLZ
Description
IC ADC 3.5DIGIT LCD LP 40DIP
Manufacturer
Intersil
Datasheet

Specifications of ICL7136CPLZ

Display Type
LCD
Configuration
7 Segment
Digits Or Characters
A/D 3.5 Digits
Current - Supply
70µA
Voltage - Supply
4 V ~ 6 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Through Hole
Package / Case
40-DIP (0.600", 15.24mm)
Package
40PDIP
Resolution
3 1/2 Digit
Sampling Rate
3 SPS
Architecture
Dual Slope
Number Of Analog Inputs
1
Digital Interface Type
LCD
Input Type
Voltage
Polarity Of Input Voltage
Bipolar
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Interface
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ICL7136CPLZ
Manufacturer:
INTERSIL
Quantity:
9 756
Part Number:
ICL7136CPLZ
Manufacturer:
INTERSIL
Quantity:
20 000
are connected to the external pins. The converter then
integrates the differential voltage between IN HI and IN LO
for a fixed time. This differential voltage can be within a wide
common mode range: up to 1V from either supply. If, on the
other hand, the input signal has no return with respect to the
converter power supply, IN LO can be tied to analog
COMMON to establish the correct common mode voltage. At
the end of this phase, the polarity of the integrated signal is
determined.
De-Integrate Phase
The final phase is de-integrate, or reference integrate. Input
low is internally connected to analog COMMON and input
high is connected across the previously charged reference
capacitor. Circuitry within the chip ensures that the capacitor
will be connected with the correct polarity to cause the
integrator output to return to zero. The time required for the
output to return to zero is proportional to the input signal.
Specifically the digital reading displayed is:
Zero Integrator Phase
The final phase is zero integrator. First, input low is shorted to
analog COMMON. Second, the reference capacitor is charged
to the reference voltage. Finally, a feedback loop is closed
around the system to IN HI to cause the integrator output to
return to zero. Under normal conditions, this phase lasts for
between 11 to 140 clock pulses, but after a “heavy” overrange
conversion, it is extended to 740 clock pulses.
DISPLAY READING = 1000
COMMON
IN LO
IN HI
31
32
30
STRAY
V+
10µA
INT
INT
C
A-Z
REF
-------------- -
V
34
V
REF
+
IN
7
REF HI
.
36
DE-
DE+
A-Z,
ZI
A-Z AND DE(±)
AND ZI
C
REF
FIGURE 2. ANALOG SECTION OF ICL7136
A-Z,
DE+
DE-
ZI
35
REF LO
33
N
C
V-
REF
ICL7136
26
INPUT
+
STRAY
-
HIGH
-
+
-
Differential Input
The input can accept differential voltages anywhere within the
common mode range of the input amplifier, or specifically from
0.5V below the positive supply to 1V above the negative supply.
In this range, the system has a CMRR of 86dB typical.
However, care must be exercised to assure the integrator
output does not saturate. A worst case condition would be a
large positive common mode voltage with a near full scale
negative differential input voltage. The negative input signal
drives the integrator positive when most of its swing has been
used up by the positive common mode voltage. For these
critical applications the integrator output swing can be reduced
to less than the recommended 2V full scale swing with little loss
of accuracy. The integrator output can swing to within 0.3V of
either supply without loss of linearity.
Differential Reference
The reference voltage can be generated anywhere within the
power supply voltage of the converter. The main source of
common mode error is a roll-over voltage caused by the
reference capacitor losing or gaining charge to stray
capacity on its nodes. If there is a large common mode
voltage, the reference capacitor can gain charge (increase
voltage) when called up to de-integrate a positive signal but
lose charge (decrease voltage) when called up to de-
integrate a negative input signal. This difference in reference
for positive or negative input voltage will give a roll-over
error. However, by selecting the reference capacitor such
that it is large enough in comparison to the stray
capacitance, this error can be held to less than 0.5 count
worst case. (See Component Value Selection.)
BUFFER
28
R
INT
2.8V
V+
1
6.2V
29
A-Z
INTEGRATOR
INPUT
LOW
C
AZ
A-Z
ZI
+
-
COMPARATOR
27
INT
C
+
-
INT
TO
DIGITAL
SECTION
July 21, 2005
FN3086.6

Related parts for ICL7136CPLZ