SWITCH DUAL CHAN PWR TO-220AB7

BTS621L1

Manufacturer Part NumberBTS621L1
DescriptionSWITCH DUAL CHAN PWR TO-220AB7
ManufacturerInfineon Technologies
SeriesPROFET®
TypeHigh Side
BTS621L1 datasheet
 


Specifications of BTS621L1

Input TypeNon-InvertingNumber Of Outputs2
On-state Resistance80 mOhmCurrent - Output / Channel4.4A
Current - Peak Output14AVoltage - Supply5 V ~ 34 V
Operating Temperature-40°C ~ 150°CMounting TypeThrough Hole
Package / CaseTO-220AB-7 (Bent Leads)Lead Free Status / RoHS StatusContains lead / RoHS non-compliant
Other namesBTS621L1IN
SP000011277
  
1
Page 1
2
Page 2
3
Page 3
4
Page 4
5
Page 5
6
Page 6
7
Page 7
8
Page 8
9
Page 9
10
Page 10
11
12
13
14
15
16
Page 5/16

Download datasheet (340Kb)Embed
PrevNext
Parameter and Conditions,
at T
= 25 °C, V
= 12 V unless otherwise specified
j
bb
Protection Functions
9)
Initial peak short circuit current limit (pin 4 to 1
or 7)
Repetitive short circuit shutdown current limit
T
= T
(see timing diagrams, page 11)
j
jt
Output clamp (inductive load switch off)
at V
= V
- V
I
= 40 mA, T
L
OUT
bb
ON(CL)
Thermal overload trip temperature
Thermal hysteresis
Reverse battery (pin 4 to 2)
Reverse battery voltage drop
I
= -2.9 A, each channel
L
Diagnostic Characteristics
Open load detection current
(on-condition)
Open load detection voltage
11
Internal output pull down
(pin 1
7 to 2), V
=5 V, T
or
OUT
)
9
Integrated protection functions are designed to prevent IC destruction under fault conditions described in the
data sheet. Fault conditions are considered as "outside" normal operating range. Protection functions are
not designed for continuous repetitive operation.
) Requires 150
10
resistor in GND connection. The reverse load current through the intrinsic drain-source
diode has to be limited by the connected load. Note that the power dissipation is higher compared to normal
operating conditions due to the voltage drop across the intrinsic drain-source diode. The temperature
protection is not active during reverse current operation! Input and Status currents have to be limited (see
max. ratings page 2 and circuit page 8).
11)
External pull up resistor required for open load detection in off state.
Semiconductor Group
Symbol
each channel
I
L(SCp)
=-40°C:
T
j
=25°C:
T
j
=+150°C:
T
j
I
L(SCr)
=-40..+150°C: V
j
ON(CL)
T
jt
T
jt
)
-V
10
bb
(V
> V
)
out
bb
T
=150 °C: -V
j
ON(rev)
T
=-40 °C
I
:
j
L (OL)
T
=25 ..150°C:
j
) (off-condition)
V
OUT(OL)
T
=-40..150°C:
j
=-40..150°C
R
j
O
5
PROFET ® BTS621L1
Values
Unit
min
typ
max
11
18
25
A
9
14
22
5
8
14
--
8
--
A
41
47
53
V
150
--
--
°C
--
10
--
K
--
--
32
V
--
mV
610
--
20
--
400
mA
20
--
300
2
3
4
V
4
10
30
k
2003-Oct-01