Page 1
Smart High-Side Power Switch PROFET BTS721L1 ...
Page 2
Smart Four Channel Highside Power Switch Features Overload protection Current limitation Short-circuit protection Thermal shutdown Overvoltage protection (including load dump) Fast demagnetization of inductive loads 1 ) Reverse battery protection Undervoltage and overvoltage shutdown with auto-restart and hysteresis Open drain ...
Page 3
Block diagram Four Channels; Open Load detection in on state; 9 Data Sheet Smart High-Side Power Switch 3 BTS721L1 Rev. 1.3, 2010-03-16 ...
Page 4
Maximum Ratings 25°C unless otherwise specified j Parameter Supply voltage (overvoltage protection see page 4) Supply voltage for full short circuit protection T = -40 ...+150°C j,start Load current (Short-circuit current, see page ...
Page 5
Electrical Characteristics Parameter and Conditions ° unless otherwise specified j bb Load Switching Capabilities and Characteristics On-state resistance ( OUT each channel, L two parallel channels, ...
Page 6
Parameter and Conditions ° unless otherwise specified j bb Leakage output current (included Operating current 5V ...
Page 7
Parameter and Conditions ° unless otherwise specified j bb Diagnostic Characteristics Open load detection current, each channel, T Open load detection voltage Internal output pull down (OUT to GND ...
Page 8
Truth Table Channel 1 and 2 Channel 3 and 4 (equivalent to channel 1 and 2) Normal operation Open load Short circuit Overtemperature Undervoltage/ Overvoltage L = "Low" Level X = don't care H = "High" Level ...
Page 9
Input circuit (ESD protection), ESD zener diodes are not to be used as voltage clamp at DC conditions. Operation in this mode may result in a drift of the zener voltage (increase V). Status output, ST1/2 ...
Page 10
Open-load detection, OUT1...4 ON-state diagnostic condition: V < R · high L(OL) OFF-state diagnostic condition: V > typ.; IN low OUT GND disconnect (channel 1/2 or 3/4) Any kind of load. In case ...
Page 11
Inductive load switch-off energy dissipation Energy stored in load inductance · · While demagnetizing load inductance, the energy dissipated in PROFET ...
Page 12
Typ. on-state resistance ; high L R [mOhm] ON Typ. open load detection current IN = high L(OL) Data Sheet Smart High-Side Power Switch Typ. standby current ; V ...
Page 13
Timing diagrams Timing diagrams are shown for chip 1 (channel 1/2). For chip 2 (channel 3/4) the diagrams are valid too. The channels 1 and 2, respectively 3 and 4, are symmetric and consequently the diagrams are valid for each ...
Page 14
Figure 3b: Turn on into short circuit: shut down by overtemperature, restart by cooling (two parallel switched channels 1 and 2) Figure 4a: Overtemperature: Reset if T < Data Sheet Smart High-Side Power Switch Figure 5a: Open ...
Page 15
Figure 5c: Open load: detection in ON- and OFF-state (with R ), turn on/off to open load EXT IN2 channel 2: normal operation d(ST) t depends on external circuitry because of high d(ST OL5) impedance Figure 6a: Undervoltage: V bb(under) ...
Page 16
Package Outlines 1.27 +0.15 0.35 Index Marking 1) Does not include plastic or metal protrusions of 0.15 max per side 2) Does not include dambar protrusion of 0.05 max per side Figure 1 PG-DSO-20 (Plastic Dual Small Outline Package) (RoHS-compliant) ...
Page 17
Revision History Version Date Changes Rev. 1.3 2010-03-16 page 6: changed reference to the timing diagram Rev. 1.2 2009-07-21 page 1: added new coverpage page 6: Initial short circuit shutdown time changed: t off(SC) -40 ° ...
Page 18
... Infineon Technologies Office. Infineon Technologies Components may only be used in life-support devices or systems with the express written approval of Infineon Technologies failure of such components can reasonably be expected to cause the failure of that life-support device or system affect the safety or effectiveness of that device or system. Life support devices or systems are intended to be implanted in the human body support and/or maintain and sustain and/or protect human life ...