AD596AHZ Analog Devices Inc, AD596AHZ Datasheet

IC THERMOCOUPLE COND TO-100-10

AD596AHZ

Manufacturer Part Number
AD596AHZ
Description
IC THERMOCOUPLE COND TO-100-10
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD596AHZ

Output Type
Voltage
Function
Thermocouple Conditioner
Topology
Ice Point Compensation
Sensor Type
External
Sensing Temperature
-200°C ~ 760°C
Output Alarm
Yes
Output Fan
No
Voltage - Supply
5 V ~ 30 V
Operating Temperature
-55°C ~ 125°C
Mounting Type
Through Hole
Package / Case
TO-100, Metal Can (10 Leads)
Temperature Sensor Function
Temp Sensor
Operating Temperature (min)
-55
Operating Temperature (max)
125C
Operating Temperature Classification
Military
Operating Supply Voltage (min)
5V
Operating Supply Voltage (max)
30V
Ic Output Type
Voltage
Supply Current
160µA
Supply Voltage Range
5V To 30V
Sensor Case Style
TO-100
No. Of Pins
10
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Related parts for AD596AHZ

AD596AHZ Summary of contents

Page 1

...

Page 2

AD596/AD597–SPECIFICATIONS Model Min ABSOLUTE MAXIMUM RATINGS +V to – Common-Mode Input Voltage (–V Differential Input Voltage –V S Alarm Voltages +ALM –V S –ALM –V S Operating Temperature Range –55 Output Short Circuit to Common Indefinite TEMPERATURE MEASUREMENT ...

Page 3

Table I. Output Voltage vs. Thermocouple Temperature (Ambient + Thermocouple Type J AD596 Temperature Voltage Output –200 –7.890 –1370 –180 –7.402 –1282 –160 –6.821 –1177 –140 –6.159 –1058 –120 –5.426 –925 –100 –4.632 –782 –80 ...

Page 4

AD596/AD597 TEMPERATURE PROPORTIONAL OUTPUT MODE The AD596/AD597 can be used to generate a temperature proportional output of 10 mV/ C when operated with J and K type thermocouples as shown in Figure 1. Thermocouples pro- duce low level output voltages ...

Page 5

SETPOINT CONTROL MODE The AD596/AD597 can be connected as a setpoint controller as shown in Figure 2. The thermocouple voltage is cold junction compensated, amplified, and compared to an external setpoint voltage. The relationship between setpoint voltage and tempera- ture ...

Page 6

AD596/AD597 SINGLE AND DUAL SUPPLY CONNECTIONS In the single supply configuration as used in the setpoint con- troller of Figure 2, any convenient voltage from + +36 V may be used, with self-heating errors being minimized at lower ...

Page 7

TEMPERATURE CONSTANTAN (ALUMEL) IRON (CHROMEL) HEATER REV 470 – AD596/ 45.2k AD597* 10k 1.27M +V 5V 40.2k AD584 10k – 1k SET-POINT ADJUST 10k OP07 5k + 10M Figure 6. Temperature Measurement and Control –7– AD596/AD597 ...

Page 8

AD596/AD597 0.040 (1.02) MAX OUTLINE DIMENSIONS Dimensions shown in inches and (mm). 10-Pin Metal Can (TO-100) REFERENCE PLANE 0.750 (19.05) 0.500 (12.70) 0.185 (4.70) 0.160 (4.06) 0.165 (4.19) 0.250 (6.35) MIN 0.110 (2.79) 0.050 (1.27) MAX 6 5 0.115 4 ...

Related keywords