ADT7476ARQZ ON Semiconductor, ADT7476ARQZ Datasheet - Page 30

IC REMOTE THERMAL CTRLR 24QSOP

ADT7476ARQZ

Manufacturer Part Number
ADT7476ARQZ
Description
IC REMOTE THERMAL CTRLR 24QSOP
Manufacturer
ON Semiconductor
Series
dBCool®r
Datasheet

Specifications of ADT7476ARQZ

Function
Fan Control, Temp Monitor
Topology
ADC, Comparator, Fan Speed Counter, Multiplexer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-40°C ~ 125°C, External Sensor
Output Type
SMBus™
Output Alarm
No
Output Fan
Yes
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
24-QSOP
Full Temp Accuracy
+/- 0.5 C
Digital Output - Bus Interface
Serial (3-Wire, 4-Wire)
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADT7476ARQZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADT7476ARQZ-REEL
Manufacturer:
ON/安森美
Quantity:
20 000
Company:
Part Number:
ADT7476ARQZ-REEL
Quantity:
50
Part Number:
ADT7476ARQZ-REEL7
Manufacturer:
ON
Quantity:
6 028
PWM1, PWM2, PWM3 Configuration (0x5C, 0x5D,
0x5E)
[2:0] SPIN, startup timeout for PWM1 = 0x5C,
PWM2 = 0x5D, and PWM3 = 0x5E.
Disabling Fan Startup Timeout
than fixed−time spin−ups, the option exists to use fixed
spin−up times. Setting Bit 5 (FSPDIS) to 1 in Configuration
Register 1 (0x40) disables the spin−up for two TACH pulses.
Instead, the fan spins up for the fixed time as selected in
Register 0x5C to Register 0x5E.
PWM Logic State
duty cycle (noninverted) or low for 100% duty cycle
(inverted).
PWM1 Configuration (0x5C)
[4] INV.
PWM2 Configuration (0x5D)
[4] INV.
PWM3 Configuration (0x5E)
[4] INV.
Low Frequency Mode PWM Drive Frequency
application. Register 0x5F to Register 0x61 configure the
PWM frequency for PWM1 to PWM3, respectively.
PWM1, PWM 2, PWM3 Frequency Registers
(0x5F to 0x61)
[2:0] FREQ
Although fan startup makes fan spin−ups much quieter
The PWM outputs can be programmed high for 100%
The PWM drive frequency can be adjusted for the
000 = No startup timeout
001 = 100 ms
010 = 250 ms default
011 = 400 ms
100 = 667 ms
101 = 1 sec
110 = 2 sec
111 = 4 sec
0 = Logic high for 100% PWM duty cycle
1 = Logic low for 100% PWM duty cycle
0 = Logic high for 100% PWM duty cycle
1 = Logic low for 100% PWM duty cycle
0 = Logic high for 100% PWM duty cycle
1 = Logic low for 100% PWM duty cycle
000 = 11.0 Hz
001 = 14.7 Hz
010 = 22.1 Hz
011 = 29.4 Hz
100 = 35.3 Hz (default)
101 = 44.1 Hz
110 = 58.8 Hz
111 = 88.2 Hz
http://onsemi.com
30
High Frequency Mode PWM Drive
0x61 enables high frequency mode for Fan 1, Fan 2, and
Fan 3 respectively.
always 22.5 kHz. When high frequency mode is enabled, the
dc bits are automatically asserted internally and do not need
to be changed.
Fan Speed Control
manual modes:
PWM Configuration Registers (0x5C to 0x5E)
[7:5] BHVR.
manually updated by writing to Register 0x30 to Register
0x32 (PWM current duty cycle registers).
Programming the PWM Current Duty Cycle Registers
that allow the PWM duty cycle for each output to be set
anywhere from 0% to 100% in steps of 0.39%. The value to
be programmed into the PWM
Example 1: For a PWM duty cycle of 50%,
Example 2: For a PWM duty cycle of 33%,
PWM Current Duty Cycle Registers
Register 0x30 PWM1 Current Duty Cycle = 0xFF (100% default)
Register 0x31 PWM2 Current Duty Cycle = 0xFF (100% default)
Register 0x32 PWM3 Current Duty Cycle = 0xFF (100% default)
user can keep track of the current duty cycle on each PWM
output, even when the fans are running in automatic fan
speed control mode or acoustic enhancement mode.
Setting Bit 3 of Register 0x5F, Register 0x60, and Register
In high frequency mode, the PWM drive frequency is
The ADT7476 controls fan speed using automatic and
Once under manual control, each PWM output can be
The PWM current duty cycle registers are 8−bit registers
By reading the PWMx current duty cycle registers, the
In automatic fan speed control mode, fan speed is
automatically varied with temperature and without CPU
intervention once initial parameters are set up. The
advantage is that if the system hangs, the user is
guaranteed that the system is protected from
overheating.
In manual fan speed control mode, the ADT7476
allows the duty cycle of any PWM output to be
adjusted manually. This can be useful if the user wants
to change fan speed in software or adjust PWM duty
cycle output for test purposes. Bits [7:5] of Register
0x5C to Register 0x5E (PWM Configuration) control
the behavior of each PWM output.
111 = manual mode
Value (decimal) = PWM
Value (decimal) = 50/0.39 = 128 (decimal)
Value = 128 (decimal) or 0x80 (hex)
Value (decimal) = 33/0.39 = 85 (decimal)
Value = 85 (decimal) or 0x54 (hex)
MIN
MIN
/0.39
register is given by:

Related parts for ADT7476ARQZ