HCPL-0201-500E Avago Technologies US Inc., HCPL-0201-500E Datasheet - Page 9

OPTOCOUPLER LOG-OUT 5MBD 8-SOIC

HCPL-0201-500E

Manufacturer Part Number
HCPL-0201-500E
Description
OPTOCOUPLER LOG-OUT 5MBD 8-SOIC
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of HCPL-0201-500E

Package / Case
8-SOIC (0.154", 3.90mm Width)
Voltage - Isolation
3750Vrms
Number Of Channels
1, Unidirectional
Current - Output / Channel
25mA
Data Rate
5MBd
Propagation Delay High - Low @ If
150ns @ 3mA
Current - Dc Forward (if)
5mA
Input Type
DC
Output Type
Push-Pull, Totem-Pole
Mounting Type
Surface Mount
Isolation Voltage
3750 Vrms
Maximum Continuous Output Current
25 mA
Maximum Fall Time
0.007 us
Maximum Forward Diode Current
10 mA
Output Device
Logic Gate Photo IC
Configuration
1 Channel
Maximum Baud Rate
5 MBd(Typ)
Maximum Forward Diode Voltage
1.7 V
Maximum Reverse Diode Voltage
5 V
Maximum Power Dissipation
210 mW
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
516-1483-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HCPL-0201-500E
Manufacturer:
AVAGO
Quantity:
30 000
Part Number:
HCPL-0201-500E
Manufacturer:
AVAGO
Quantity:
25 363
Part Number:
HCPL-0201-500E
Manufacturer:
AVAGO
Quantity:
25 363
Part Number:
HCPL-0201-500E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Company:
Part Number:
HCPL-0201-500E
Quantity:
10 000
Company:
Part Number:
HCPL-0201-500E
Quantity:
4 500
Company:
Part Number:
HCPL-0201-500E
Quantity:
395
9
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics
(HCNW22XX ONLY)
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section IEC/EN/DIN EN 60747-5-2, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in applica-
tion.
Description
Installation classification per DIN VDE 0110/1.89, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
Input to Output Test Voltage, Method a*
Highest Allowable Overvoltage*
(Transient Overvoltage, t
Safety Limiting Values
Insulation Resistance at T
V
V
for rated mains voltage ≤600 V rms
for rated mains voltage ≤1000 V rms
Partial Discharge < 5 pC
t
(Maximum values allowed in the event of a failure,
also see Figure 12, Thermal Derating curve.)
m
IORM
IORM
= 60 sec, Partial Discharge < 5 pC
Case Temperature
Current (Input Current I
Output Power
x 1.875 = V
x 1.5 = V
PR
, Type and sample test,
PR
, 100% Production Test with t
ini
S
, V
= 10 sec)
IO
F
, P
= 500 V
S
= 0)
m
= 1 sec,
Symbol
P
I
S,OUTPUT
V
V
S,INPUT
V
V
IORM
T
R
IOTM
PR
PR
S
S
Characteristic
55/100/21
1414
2652
2121
8000
≥10
150
400
700
I-III
I-IV
2
9
Units
V
V
V
V
mW
mA
°C
Ω
peak
peak
peak
peak

Related parts for HCPL-0201-500E