HCPL-2530-000E Avago Technologies US Inc., HCPL-2530-000E Datasheet - Page 8

OPTOCOUPLER T-OUT 2CH 1MBD 8-DIP

HCPL-2530-000E

Manufacturer Part Number
HCPL-2530-000E
Description
OPTOCOUPLER T-OUT 2CH 1MBD 8-DIP
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of HCPL-2530-000E

Input Type
DC
Package / Case
8-DIP (0.300", 7.62mm)
Voltage - Isolation
3750Vrms
Number Of Channels
2, Unidirectional
Current - Output / Channel
8mA
Data Rate
1MBd
Propagation Delay High - Low @ If
200ns @ 16mA
Current - Dc Forward (if)
25mA
Output Type
Open Collector
Mounting Type
Through Hole
Isolation Voltage
3750 Vrms
Output Device
Transistor With Base
Configuration
2 Channel
Current Transfer Ratio
50 %
Maximum Baud Rate
1 MBps
Maximum Forward Diode Voltage
1.8 V
Maximum Reverse Diode Voltage
5 V
Maximum Input Diode Current
25 mA
Maximum Power Dissipation
45 mW
Maximum Operating Temperature
+ 100 C
Minimum Operating Temperature
- 55 C
No. Of Channels
2
Optocoupler Output Type
Phototransistor
Input Current
16mA
Output Voltage
20V
Opto Case Style
DIP
No. Of Pins
8
Ctr Min
7%
Common Mode Ratio
1k
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
516-1659-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HCPL-2530-000E
Manufacturer:
AVAGO
Quantity:
40 000
Part Number:
HCPL-2530-000E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Company:
Part Number:
HCPL-2530-000E
Quantity:
17
IEC/EN/DIN EN 60747-5-2 Insulation Characteristics (Option 060)
Description
Installation classification per DIN VDE 0110/1.89, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
Input to Output Test Voltage, Method a*
Highest Allowable Overvoltage
(Transient Overvoltage, t
Safety Limiting Values
(Maximum values allowed in the event of a failure.)
Insulation Resistance at T
*
** Refer to the following figure for dependence of P
Note: Isolation characteristics are guaranteed only within the safety maximum ratings, which must be ensured by protective circuits in application.
8
for rated mains voltage ≤ 150 V rms
for rated mains voltage ≤ 300 V rms
for rated mains voltage ≤ 600 V rms
V
with t
V
t
Case Temperature
Input Current**
Output Power**
Refer to the optocoupler section of the Isolation and Control Components Designer's Catalog, under Product Safety Regulations section,
IEC/EN/DIN EN 60747-5-2, for a detailed description of Method a and Method b partial discharge test profiles.
m
IORM
IORM
= 60 sec, Partial Discharge < 5 pC
m
x 1.875 = V
x 1.5 = V
= 1 sec, Partial Discharge < 5 pC
800
700
600
500
400
300
200
100
0
PR
0
, Type and Sample Test,
PR
T
, 100% Production Test
25
S
ini
– CASE TEMPERATURE – °C
S
, V
50
= 10 sec)
IO
= 500 V
75 100
P
I
S
S
(mA)
(mW)
125
150 175
S
and I
S
200
on ambient temperature.
Symbol
V
V
V
V
T
I
P
R
S,INPUT
S
IORM
PR
PR
IOTM
S,OUTPUT
S
Characteristic
HCPL-
2530/2531/4534
I-IV
I-III
55/100/21
2
630
1181
945
6000
175
230
600
> 10
9
HCPL-
0530/0531/0534
I-IV
I-III
I-II
55/100/21
2
567
1050
840
4000
150
230
600
> 10
9
Unit
V
V
V
V
˚C
mA
mW
:
peak
peak
peak
peak

Related parts for HCPL-2530-000E