HCPL-2601#500 Avago Technologies US Inc., HCPL-2601#500 Datasheet - Page 9

OPTOCOUPLER 1CH 10MBD 8-SMD

HCPL-2601#500

Manufacturer Part Number
HCPL-2601#500
Description
OPTOCOUPLER 1CH 10MBD 8-SMD
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of HCPL-2601#500

Package / Case
8-SMD Gull Wing
Voltage - Isolation
3750Vrms
Number Of Channels
1, Unidirectional
Current - Output / Channel
50mA
Data Rate
10MBd
Propagation Delay High - Low @ If
50ns @ 7.5mA
Current - Dc Forward (if)
20mA
Input Type
DC
Output Type
Open Collector
Mounting Type
Surface Mount, Gull Wing
Isolation Voltage
3750 Vrms
Maximum Continuous Output Current
50 mA
Maximum Fall Time
10 ns
Maximum Forward Diode Current
20 mA
Maximum Rise Time
24 ns
Minimum Forward Diode Voltage
1.4 V
Output Device
Logic Gate Photo IC
Configuration
1 Channel
Maximum Baud Rate
10 MBps
Maximum Forward Diode Voltage
1.75 V
Maximum Reverse Diode Voltage
5 V
Maximum Power Dissipation
85 mW
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
HCPL-2601#500HCPL-2601
Manufacturer:
AVAGO
Quantity:
2 900
Company:
Part Number:
HCPL-2601#500HCPL-2601
Manufacturer:
AGI
Quantity:
1 000
Company:
Part Number:
HCPL-2601#500HCPL-2601
Manufacturer:
HP
Quantity:
8 000
Company:
Part Number:
HCPL-2601#500HCPL-2601
Quantity:
454
Company:
Part Number:
HCPL-2601#500HCPL-2601#300
Manufacturer:
AGILENT
Quantity:
4 000
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics
(HCPL-06xx Option 060 Only)
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, IEC/EN/DIN EN 60747-5-2, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in applica-
tion.
9
Description
Installation classification per DIN VDE 0110/1.89, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
Input to Output Test Voltage, Method a*
Highest Allowable Overvoltage
(Transient Overvoltage, t
Safety Limiting Values
Insulation Resistance at T
V
V
for rated mains voltage ≤ 150 V rms
for rated mains voltage ≤ 300 V rms
for rated mains voltage ≤ 600 V rms
Partial Discharge < 5 pC
t
(Maximum values allowed in the event of a failure)
m
IORM
IORM
Case Temperature
Input Current**
Output Power**
= 60 sec, Partial Discharge < 5 pC
x 1.875 = V
x 1.5 = V
PR
, Type and Sample Test,
PR
, 100% Production Test with t
ini
S
, V
= 10 sec)
IO
= 500 V
m
= 1 sec,
P
Symbol
I
S,OUTPUT
V
V
S,INPUT
V
V
IORM
IOTM
T
R
PR
PR
S
S
Characteristic
55/85/21
1063
6000
≥10
567
851
150
150
600
I-IV
I-III
I-III
2
9
Units
V
V
V
V
mW
mA
°C
:
peak
peak
peak
peak

Related parts for HCPL-2601#500