HCPL-2601-360E Avago Technologies US Inc., HCPL-2601-360E Datasheet - Page 10

OPTOCOUPLER 10MBD VDE 8-SMD GW

HCPL-2601-360E

Manufacturer Part Number
HCPL-2601-360E
Description
OPTOCOUPLER 10MBD VDE 8-SMD GW
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of HCPL-2601-360E

Package / Case
8-SMD Gull Wing
Voltage - Isolation
3750Vrms
Number Of Channels
1, Unidirectional
Current - Output / Channel
50mA
Data Rate
10MBd
Propagation Delay High - Low @ If
50ns @ 7.5mA
Current - Dc Forward (if)
20mA
Input Type
DC
Output Type
Open Collector
Mounting Type
Surface Mount, Gull Wing
Isolation Voltage
3750 Vrms
Maximum Continuous Output Current
50 mA
Maximum Fall Time
10 ns
Maximum Forward Diode Current
20 mA
Maximum Rise Time
24 ns
Minimum Forward Diode Voltage
1.4 V
Output Device
Logic Gate Photo IC
Configuration
1 Channel
Maximum Baud Rate
10 MBps
Maximum Forward Diode Voltage
1.75 V
Maximum Reverse Diode Voltage
5 V
Maximum Power Dissipation
85 mW
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HCPL-2601-360E
Manufacturer:
AVAGO
Quantity:
30 000
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics
(HCPL-26xx; 46xx; 6N13x Option 060 Only)
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, IEC/EN/DIN EN 60747-5-2, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in applica-
tion.
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics (HCNW137/2601/2611 Only)
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, IEC/EN/DIN EN 60747-5-2, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in applica-
tion.
10
Description
Installation classification per DIN VDE 0110/1.89, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
Input to Output Test Voltage, Method a*
Highest Allowable Overvoltage*
(Transient Overvoltage, t
Safety Limiting Values
Insulation Resistance at T
Description
Installation classification per DIN VDE 0110/1.89, Table 1
Climatic Classification (DIN IEC 68 part 1)
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
Input to Output Test Voltage, Method a*
Highest Allowable Overvoltage*
(Transient Overvoltage, t
Safety Limiting Values
Insulation Resistance at T
V
V
V
V
for rated mains voltage ≤ 300 V rms
for rated mains voltage ≤ 450 V rms
Partial Discharge < 5 pC
t
(Maximum values allowed in the event of a failure,
also see Figure 16, Thermal Derating curve.)
for rated mains voltage ≤600 V rms
for rated mains voltage ≤1000 V rms
Partial Discharge < 5 pC
t
(Maximum values allowed in the event of a failure,
also see Figure 16, Thermal Derating curve.)
m
m
IORM
IORM
IORM
IORM
Case Temperature
Input Current
Output Power
Case Temperature
Input Current
Output Power
= 60 sec, Partial Discharge < 5 pC
= 60 sec, Partial Discharge < 5 pC
x 1.875 = V
x 1.5 = V
x 1.875 = V
x 1.5 = V
PR
PR
, Type and sample test,
, Type and sample test,
PR
PR
, 100% Production Test with t
, 100% Production Test with t
ini
ini
S
S
, V
, V
= 10 sec)
= 10 sec)
IO
IO
= 500 V
= 500 V
m
m
= 1 sec,
= 1 sec,
P
P
Symbol
Symbol
I
I
S,OUTPUT
S,OUTPUT
V
V
V
V
S,INPUT
S,INPUT
V
V
V
V
IORM
T
R
IORM
T
R
IOTM
IOTM
PR
PR
PR
PR
S
S
S
S
Characteristic
Characteristic
55/100/21
55/85/21
1181
6000
1414
2651
2121
8000
≥10
≥10
630
945
175
230
600
150
400
700
I-IV
I-III
I-IV
I-III
2
2
9
9
Units
Units
V
V
V
V
V
V
V
V
mW
mW
mA
mA
°C
°C
:
:
peak
peak
peak
peak
peak
peak
peak
peak

Related parts for HCPL-2601-360E